Flowmax · Transient

Validated against the textbooks

The transient solver of Flowmax is checked against the closed-form theory of hydraulic transients: results any engineer can verify in Wylie & Streeter, Chaudhry, Thorley, Parmakian and Jaeger.

10benchmark cases
121values compared
121within tolerance
2.7 %largest deviation
The ten cases

Theory against Flowmax.

CaseTheoryValues comparedLargest deviationResult
AWave speed of a liquid in an elastic pipe271.14 %✓ within
BInstantaneous closure: the Joukowsky rise and the timing of the wave180.96 %✓ within
CGradual closure: Allievi's interlocking equations190.035 m✓ within
DEstablishment of flow: the rigid water column101.06 %✓ within
EMass oscillation of a surge tank52.68 %✓ within
FAir vessel: the column on a gas spring101.32 %✓ within
GA tank whose level moves: draining through a valve50.39 %✓ within
HRun-down of a tripped pump on a resistance60.56 %✓ within
IColumn separation at a closed valve: the discrete vapour cavity122.48 %✓ within
KSurge relief valve: opening and flow90.00 %✓ within
How a case is judged

Nothing tuned to fit.

The smallest model

Each case builds the smallest Flowmax model the theory describes, runs it, and sets the two results side by side.

A tolerance on every value

1 to 3 % for a quantity the theory gives exactly, and one or two time steps for a time.

Nothing adjusted

A value outside its tolerance is never tuned to fit: it is explained, and what it says about the program is reported.

What the comparison looks like

Three of the ten cases.

Run your own transient study.

Try the Transient mode of Flowmax on your own network.

Request a free trial