Skip to the text
Flowmax · Gas & Multiphase

Quick Start

Gas & Multiphase · October 2026

This is the shortest way from an empty sheet to a result. It has no example in it: it says what is pressed, in what order, and what the program answers. The training manual of the mode works through complete systems and explains every window; come back to this page for the order of things.

1 The window and the mode#

A gas network after its Run: the mass flow on the links, the pressure and the temperature at the nodes.
Figure 1 A gas network after its Run: the mass flow on the links, the pressure and the temperature at the nodes.

2 A gas network in eight steps#

  1. The fluid. On the Home page press Fluid (Figure 2): its components and their fractions, by moles or by mass, and its method - Peng-Robinson or SRK for hydrocarbons, GERG-2008 for natural gas and hydrogen, CPA where there is water, IAPWS-IF97 for water and steam alone. A second fluid has its own tab, for a stream of its own.
  2. Draw. Press a square of the Equipment strip and click twice on the sheet, its start and its end; click on an existing node to join it. A new pipe comes as 10 inch of schedule 40 (the reduced list), the default of the Settings.
  3. The streams. An inlet stream brings the fluid in: its Flow or its Pressure, and its temperature (Figure 3). An outlet stream takes it out at its Pressure. At least one stream fixes a pressure.
  4. The equipment. A valve: its Cv and its opening, or what it holds - a flow, a pressure. A compressor: its ratio, its outlet pressure, its power, or its curve, with its efficiency. An exchanger: its duty or its outlet temperature; two exchangers can be the two sides of one. A pipe: its length, size, roughness, and how it exchanges heat.
  5. The separators (Figure 4). A node made a separator splits its gas from its liquid, or its oil from its water as well; each liquid leaves by the line of its level valve. Separate by also offers a splitter of given recoveries and a column of stages.
  6. Read the status bar. While it says Missing inputs, click it: the list names what is not yet given. When it says Ready to run, press Run. HMB only on the Home page solves the heat and material balance without the pressure losses of the pipes - a first run of a big plant.
  7. Read the results. The label selectors write the flow, the pressure, the temperature or the vapour fraction beside every link and node. The H&MB of the Tools page lays every stream side by side; the Property probe reads a dew point, a hydrate temperature or a water cut at a node; Add table puts any of them on the sheet.
  8. Keep it. Save writes the project file. The Reports page makes a PDF Report, the Datasheets and an Excel workbook.
The Fluid window of the gas mode: the components, their fractions and the method.
Figure 2 The Fluid window of the gas mode: the components, their fractions and the method.
An inlet stream: its flow or its pressure, its temperature, its fluid.
Figure 3 An inlet stream: its flow or its pressure, its temperature, its fluid.
A separator: its type, its level valves, what it separates by.
Figure 4 A separator: its type, its level valves, what it separates by.

3 Before a result is used#

Next: the Gas Training Manual, twenty examples - ten networks and ten facilities - each with its project file.