About this manual#

The gas mode of FlowMax solves networks of gas, of gas and liquid, and of water and steam, in steady state: the pressure and the temperature at every node, the flow and the phases in every link, the duty of every exchanger and the power of every machine. This manual teaches it through twenty examples - ten networks and ten facilities, each group from the smallest to the biggest: from a fuel gas system to a flare network of fifteen relief valves and a town's grid of 760 pipes, and from a boil-off gas compressor to an oil production facility and a whole LNG plant with its utilities.

The first, the fuel gas system, is built step by step. The others are opened and run as their project files stand, and read: the sheet after the Run, the streams, the equipment, what the Run says, and what to retain.

Most of them are worked out from compositions, by an equation of state. N09, an oil field of twelve wells, is worked out by black oil, each well an oil of its own ; F09 makes a fluid from its well fluid by its GOR and its water cut, and runs its wells both ways, by composition and by black oil.

The examples are illustrative. Their numbers are chosen for teaching and are typical of the industry; they come from no plant. Every number in the text, the tables and the figures is the program's own, read from the run that made the page.

The twenty examples#

Table 1 The examples, each group from the smallest to the biggest
ExampleWhat it isLinks
N01Fuel gas system25
N02Subsea flowline and riser4
N03CO2 injection wells10
N04Compressor station and export line19
N05City gate station21
N06Plant air and nitrogen33
N07Wells to a central processing facility33
N08Flare network, three areas42
N09Oil field gathering, black oil48
N10City gas grid760
F01LNG boil-off gas9
F02Steam system of an LNG plant10
F03NGL column, five feeds and side draws19
F04NGL recovery, gas subcooled process (GSP)45
F05Dew point plant22
F06Gas processing train22
F07Compression and cooling water26
F08Water and steam loop32
F09Oil production facility50
F10LNG plant with its utilities105

Units#

The examples use the units of a metric oil and gas project: kg/h, barg for pressures, bar for pressure drops, °C, m, mm for diameters, kW, MSm³/d for standard gas flows and m³/h for actual flows. The page Unit System of the Settings changes them; the gas mode has its own rows there for the standard and the actual flow.

The project files#

Each example is a project file named after its chapter, N01 to N10 and F01 to F10. It opens with File > Open and runs as it is.

Their sheets are drawn with 90° lines (the tick in the ribbon's Sheet group): each line with square bends, out of a vessel's nozzle the way it points. Whatever feeds a network is an Inlet stream - given its flow, or, where the source is a header, a well or a supply held at a pressure, given its Pressure, its flow then the result. What leaves is an Outlet stream, given its pressure or its flow. Each sheet is shown whole, after its Run; a wide one on an A3 page of its own, across.

N01 A fuel gas system#

A plant burns part of its own gas: in its gas turbines, which drive generators and compressors, in its fired heaters, and in the pilots that keep its flare alight. The fuel gas system takes that gas from a high-pressure header and delivers it to each user at the pressure the user needs, clean, dry and warm enough. The pressure is let down in steps, and a gas let down cools - the Joule-Thomson effect - so the gas is heated before the first let-down; a knock-out drum after it catches any liquid.

This example builds such a system, small enough to set up in a quarter of an hour: one header, one filter, one heater, two pressure-control valves, a knock-out drum, and six users on flow control. It teaches the inlet stream given its pressure, the exchanger, the specifications of a valve, the separator, and how to read the temperature a let-down gives.

N01 after its Run: the names, the mass flow on the links (kg/h) and the pressure at the nodes (barg). The colours follow the flow and the pressure.
Figure 1 N01 after its Run: the names, the mass flow on the links (kg/h) and the pressure at the nodes (barg). The colours follow the flow and the pressure.

The fluid#

Table 2 The fuel gas, mole %
ComponentMole %
Methane86.5
Ethane6.0
Propane2.5
i-Butane0.5
n-Butane0.7
i-Pentane0.2
n-Pentane0.2
n-Hexane0.4
n-Heptane0.2
Nitrogen1.3
CO21.5

A gas from a plant, mostly methane, with a little of the heavier hydrocarbons up to heptane. Those few tenths of a per cent of hexane and heptane decide its dew point: the temperature at which, at a given pressure, its first drop of liquid condenses. The method of properties is Peng-Robinson, the one FlowMax advises for natural gas.

  1. On the New project page choose Gas.
  2. Open the Fluid window from the ribbon, add the components and their mole fractions, keep Peng-Robinson, and press Confirm.
The Fluid window with the fuel gas. Its molar mass and its density at standard conditions are worked out as it is typed.
Figure 2 The Fluid window with the fuel gas. Its molar mass and its density at standard conditions are worked out as it is typed.

The network#

Table 3 The elements of N01
ElementWhat it isDataWhat it does
HDRInlet stream, given its pressure70 barg, 30 °CThe plant's fuel gas header : it gives what the network takes
FLTPressure drop0.3 bar at 20 000 kg/hThe filter
HTRExchanger0.5 bar at 20 000 kg/h ; outlet 60 °CThe fuel gas heater
PCV-1Valve, Pressure setCv 30 ; 25 barg at V2The first let-down
KOSeparator, two phasesIts liquid by LV-1The knock-out drum
LV-1ValveCv 0.5Its level valve, to DRAIN at 1 barg
FCV-1, FCV-2Valves, Flow setCv 50 ; 9 000 kg/h eachThe gas turbines GT-1 and GT-2, at 18 barg
PCV-2Valve, Pressure setCv 10 ; 6 barg at LPHThe second let-down
FCV-A, B, CValves, Flow setCv 12 ; 720 kg/h eachThree fired heaters, at 0.5 barg
FCV-PValve, Flow setCv 1.2 ; 72 kg/hThe flare pilots, at 0.5 barg
Table 4 The pipes of N01 : steel, roughness 0.045 mm
PipesLengthInside diameter
P-1, P-2, P-3 : header to PCV-150, 10, 10 m154 mm (6 in)
P-4, P-5 : PCV-1 to the HP header HPH20, 30 m203 mm (8 in)
P-6, P-7 : the drum's liquid5, 30 m26.6 mm (1 in)
P-8, P-9 : to the turbines200, 220 m154 mm (6 in)
P-10 : to PCV-2150 m102 mm (4 in)
P-11, P-12, P-13 : to the heaters120, 140, 160 m78 mm (3 in)
P-14 : to the pilots300 m26.6 mm (1 in)

The header#

The header is an Inlet stream given its Pressure: a node that holds a pressure. Whatever the network asks of it, it gives; its flow is the result, what the users burn. The temperature it is given is that of the gas that comes in.

  1. Draw the pipes with the Pipe tool, as on the sheet.
  2. Press Inlet on the Equipment panel and click the first node : it becomes HDR. Open it, choose Given : Pressure, give 70 barg and 30 °C.
The header HDR : an inlet stream given its pressure, 70 barg ; the gas comes in at 30 °C. Its flow is a result.
Figure 3 The header HDR : an inlet stream given its pressure, 70 barg ; the gas comes in at 30 °C. Its flow is a result.

The filter and the heater#

A filter is a pressure drop: its drop at one flow is given, and FlowMax scales it with the square of the flow. The heater is the same, with a temperature to give the gas on its Heat Transfer tab; its duty is a result.

  1. Press PD and click between F1 and F2 : the filter. Give 20 000 kg/h and 0.3 bar.
  2. Press Exchanger and click between H1 and H2 : the heater. The same reference flow and 0.5 bar ; on Heat Transfer, the outlet temperature, 60 °C.
The filter FLT : a drop of 0.3 bar at 20 000 kg/h.
Figure 4 The filter FLT : a drop of 0.3 bar at 20 000 kg/h.
The heater HTR, its Heat Transfer tab : the gas leaves at 60 °C.
Figure 5 The heater HTR, its Heat Transfer tab : the gas leaves at 60 °C.

The valves#

A valve is given its Cv and a Specification. Pressure set holds a pressure at a node - its own outlet unless another is chosen - and works out the opening that does it. Flow set passes the flow given and works out its opening too. Rating leaves the opening as it is typed and works out the flow. The opening is the share of the Cv the valve needs: a sized valve runs between about 20 and 80 %.

  1. Press Valve and click between V1 and V2 : PCV-1. Cv 30, Pressure set, the node V2, 25 barg.
  2. The same for PCV-2 : Cv 10, 6 barg at LPH.
  3. The users' valves FCV-1, FCV-2, FCV-A, FCV-B, FCV-C, FCV-P : Flow set, with their flows.
  4. The users GT-1 ... PILOTS : Outlet streams at the pressure each burns at.
PCV-1 holding 25 barg at its outlet, V2.
Figure 6 PCV-1 holding 25 barg at its outlet, V2.
FCV-1, the fuel of a gas turbine : 9 000 kg/h whatever the pressures.
Figure 7 FCV-1, the fuel of a gas turbine : 9 000 kg/h whatever the pressures.

The knock-out drum#

A node becomes a separator with the Separ. button. Its window lists its outlets by the height of their far ends - the highest takes the gas, the lowest the liquid - and the valve that holds its level. The gas, the primary phase, leaves freely; the liquid leaves by its level valve, which passes what the flash at the drum condenses.

The knock-out drum KO : its gas by P-5, its liquid by P-6 and LV-1.
Figure 8 The knock-out drum KO : its gas by P-5, its liquid by P-6 and LV-1.

The Run and its results#

Run solves the network at once: the pressures, the flows, the temperatures, the phases. The users burn 20 232 kg/h, which the header gives. The filter takes 0.31 bar, the heater warms the gas from 30 to 60 °C with 447 kW. PCV-1 lets it down to 25 barg and it cools to 40.2 °C; the turbines receive it at 36.6 °C. PCV-2 lets it down again, to 29.9 °C, and the burners get it at 26.7 °C. No liquid forms anywhere: the drum stays dry and LV-1 is shut.

Table 5 The valves after the Run
ValveFlow (kg/h)Drop (bar)Outlet (°C)Opening (%)
PCV-12023244.1340.269.4
PCV-2223218.9429.963.9
FCV-190006.8936.663.7
FCV-290006.8836.663.8
FCV-A7205.4526.765.7
FCV-B7205.4526.765.8
FCV-C7205.4426.765.9
FCV-P725.1626.868.7

Each valve runs between 64 and 69 % open: sized right, with room to move. The gas cools by a few degrees in each user's valve too. The pipes are well below the velocities that would be noisy: 8.5 m/s in the HP header, 7.6 m/s to the heaters. The pressure the turbines' valves see is 24.89 barg, the heaters' 5.95 barg.

The Links table on its Valve page : each valve's specification, flow, drop and opening.
Figure 9 The Links table on its Valve page : each valve's specification, flow, drop and opening.
The Nodes table : the pressure, the temperature, the vapour fraction and the properties at every node.
Figure 10 The Nodes table : the pressure, the temperature, the vapour fraction and the properties at every node.

Variant : the heater off#

The heater keeps the gas warm through two let-downs. Take its outlet temperature away - on its Heat Transfer tab, no heat - and run again.

Table 6 The heater on and off
WhereHeater onHeater off
KO, after PCV-1 (°C)40.27.6
Gas turbines (°C)36.63.2
LP header, after PCV-2 (°C)29.9-5.3
Burners of the heaters (°C)26.7-9.3
Vapour fraction in KO1.00000.9940
Liquid out of KO (kg/h)0442
LV-1 opening (%)026.8

Let down from 70 to 25 barg at 30 °C, the gas falls to 7.6 °C: below its dew point at that pressure. 442 kg/h of hexane, heptane and the like condense, and the drum catches them; LV-1 opens to 26.8 % to pass them. The gas that leaves the drum is at its dew point, and the burners receive it at -9.3 °C. A gas at its dew point condenses again on the first cold wall, and liquid in the fuel of a gas turbine damages it; below 0 °C any water would freeze or form hydrates. That is what the heater is for.

The heater off : the links named, the temperature (°C) and the vapour fraction at the nodes. The drum KO and its liquid line carry the condensate.
Figure 11 The heater off : the links named, the temperature (°C) and the vapour fraction at the nodes. The drum KO and its liquid line carry the condensate.

Variant : the turbines at peak load#

Each turbine now burns 11 000 kg/h. The header gives 24 232 kg/h; the heater needs 538 kW, PCV-1 opens to 83.6 % and the turbines' valves to 78.3 %, their inlet at 24.83 barg. PCV-1 still holds 25 barg with room to spare. Were a flow asked that a valve cannot pass even fully open, the Run would say so - "cannot hold its setting" - and leave it fully open: the network then shows what the valve can do.

What to retain#

N02 A subsea flowline and its riser#

A gas condensate from a subsea manifold : 8 km on the seabed, 300 m below the sea, then a 320 m riser to the platform, the sea at 4 °C around it ; on the platform the choke into the separator. Beggs and Brill along the line gives the holdup and the flow pattern, and the liquid that gathers at the riser's foot.

N02 A subsea flowline and its riser after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 12 N02 A subsea flowline and its riser after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 7 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
MFInlet44.5270.006.000E446.120.9701
SEPOutlet30.005.1746.000E446.120.8224

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 8 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
HV6.000E44.522100.05.1840.8224

What the Run says#

What to retain#

N03 CO2 injection wells#

Dense CO2 from the arrival header through 3 km to the well pad, then three wells, each its wellhead piping, its choke and a tubing 2 000 m down to the reservoir, warmed by the rock. The weight of the dense column adds to the pressure going down.

N03 CO2 injection wells after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 13 N03 CO2 injection wells after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 9 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
ARRInlet98.5912.003.420E50.0000
BH-1Outlet230.026.001.203E50.0000
BH-2Outlet235.026.161.141E50.0000
BH-3Outlet240.026.331.076E50.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 10 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
CK-11.203E513.31100.011.300.0000
CK-21.141E511.98100.011.370.0000
CK-31.076E510.65100.011.430.0000

What the Run says#

What to retain#

N04 A compressor station and its export line#

A pipeline's gas arrives at 45 barg : the suction scrubber, two compressors in parallel on their curve, the aftercooler, an anti-surge valve back to the suction, and 40 km to the city gate held at 55 barg. Machines in parallel on one curve share the flow ; tripping one moves the other along its curve.

N04 A compressor station and its export line after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 14 N04 A compressor station and its export line after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 11 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
SUCInlet25.0025.002.527E5290.21.0000
GATEOutlet18.0020.912.527E5290.21.0000
DRAINOutlet5.00025.00001.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 12 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-1Curve24.7732.211.288151046.71
K-2Curve24.7732.211.288151046.71
Table 13 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
AC2.527E546.6945.00-254.5
Table 14 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
ASV07.020001.0000
LV-1019.800.0001.0000
Table 15 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
SCR2 phases24.8024.912.527E50

What the Run says#

What to retain#

N05 A city gate station#

Natural gas from the transmission line at 60 barg in winter : two filters, the heater - the gas cools about half a degree a bar through the regulators - then two regulator runs, each a monitor and an active regulator, run B the standby, and 1 km to the city.

N05 A city gate station after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 15 N05 A city gate station after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 16 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
HPInlet60.008.0006.000E468.911.0000
CITYOutlet15.1210.0006.000E41.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 17 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E-16.000E47.90530.00960.4
Table 18 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
PCV-MA6.000E41.689100.0029.311.0000
PCV-AA6.000E441.7729.1310.0001.0000
PCV-MB0.07821.740.0020.611.0000
PCV-AB0.07821.740.009.9911.0000

What the Run says#

What to retain#

N06 Plant air and nitrogen#

Plant air and a nitrogen package on one site : the air compressed and dried, a membrane - a component splitter - taking nitrogen from it, and the two distributions to their users.

N06 Plant air and nitrogen after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 16 N06 Plant air and nitrogen after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 19 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
AIRInlet030.0048203.3751.0000
IA-1Outlet7.32840.0015001.0000
IA-2Outlet7.43240.0010001.0000
DRAIN-1Outlet025.00001.0000
DRAIN-2Outlet040.1550.140.0001
PURGEOutlet019.42737.30.5220.9675
N2-1Outlet7.58240.00800.01.0000
PERMEATEOutlet038.34733.10.4951.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 20 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-1Ratio-7.628E-42.0243.000197.2173.3
K-2Ratio1.9567.8953.000203.7187.5
Table 21 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E-14820173.340.00-184.3
E-24820187.540.00-238.2
Table 22 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-101.9570.0000.9812
LV-250.147.8261.0440.150.0001
PV-1737.37.78425.5419.420.9673
PV-2733.17.76825.1138.341.0000
Table 23 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
KO-12 phases1.95740.0048200
KO-22 phases7.82640.00477050.14
DRYSplitter7.82340.0047700
MEMSplitter7.79740.0015330

What the Run says#

What to retain#

N07 Wells to a central processing facility#

Six wells - three of gas condensate, three of light oil - each through its choke and its flowline to a manifold, the two manifolds by a 15 km trunkline to the central processing facility : the HP separator, its gas to the compression, its liquid let down to the LP separator, the oil pumped to export. Several fluids meet in one network ; the flowlines carry two phases.

N07 Wells to a central processing facility after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 17 N07 Wells to a central processing facility after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 24 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
W-1Inlet140.080.001.478E40.3380.9791
W-2Inlet125.075.001.753E40.4010.9541
W-3Inlet110.070.001.905E40.4350.9381
W-4Inlet60.0065.003.312E40.4160.5788
W-5Inlet52.0062.003.106E40.3900.5958
W-6Inlet45.0060.002.611E40.3280.6122
HP GASOutlet25.0031.246.459E41.7881.0000
LP GASOutlet2.00021.1455330.1051.0000
OILOutlet15.0023.537.153E40.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 25 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
CK-11.478E4104.7100.049.590.9404
CK-21.753E487.52100.048.490.9366
CK-31.905E470.48100.047.660.9334
CK-43.312E423.33100.059.980.6364
CK-53.106E414.21100.058.750.6313
CK-62.611E47.547100.058.150.6313
LV-17.706E422.4347.2322.260.1900
LV-27.153E419.2545.9523.520.0000
Table 26 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
HPS2 phases25.0531.266.462E47.703E4
LPS2 phases2.05921.1655337.153E4
Table 27 The pumps
NameMass flow (kg/h)Pressure rise (bar)Power (kW)Outlet temperature (°C)
P-OIL7.153E431.7122.56

What the Run says#

What to retain#

N08 A flare network#

A general power failure : fifteen relief valves open at once, five in each of three process areas. Each discharges through its tail pipe - 6 in for the large ones, 4 in below 25 000 kg/h - into its area's sub-header, the three sub-headers into the main header, which grows from 20 to 30 in as the areas join it, 300 m to the knock-out drum, its liquid by a level valve to the drain, then the stack, 80 m up, and the tip. The flows and the temperatures are given at the relief valves ; the tip and the drain are at the atmosphere ; every pressure up the network - the back pressure at each relief valve above all - follows from the flow.

N08 A flare network after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 18 N08 A flare network after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 28 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
RV-A1Inlet5.35640.006.000E451.671.0000
RV-A2Inlet3.390130.02.500E421.531.0000
RV-A3Inlet4.318180.01.200E410.331.0000
RV-A4Inlet4.40325.004.000E434.451.0000
RV-A5Inlet3.40460.0080006.8891.0000
RV-B1Inlet3.10580.003.000E425.841.0000
RV-B2Inlet4.21135.004.500E438.751.0000
RV-B3Inlet4.792150.01.500E412.921.0000
RV-B4Inlet2.52845.0050004.3061.0000
RV-B5Inlet6.58890.002.000E417.221.0000
RV-C1Inlet6.07130.007.000E460.281.0000
RV-C2Inlet3.085120.01.000E48.6121.0000
RV-C3Inlet4.98760.001.800E415.501.0000
RV-C4Inlet2.682200.060005.1671.0000
RV-C5Inlet3.90040.003.500E430.141.0000
TIPOutlet059.903.990E5343.61.0000
DRAINOutlet025.00001.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 29 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-100.3730.0001.0000
Table 30 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
KO2 phases0.37360.503.990E50

What the Run says#

What to retain#

N09 An oil field gathered, by black oil#

An oil field of twelve wells in three reservoirs, gathered to its central processing facility and worked out by black oil. Each well is a fluid of its own : its reservoir's oil - 32 API by Standing's correlations for reservoir A, 40 API by Vasquez-Beggs's for B, 27 API by its PVT table at 85 °C for C - with its own gas-oil ratio and water cut, from its last well test. The A and C wells are given their test rates ; the B wells their flowing wellhead pressures, their rates the results of their chokes and lines. Each well's choke and flowline of 6 in run to its cluster's manifold, three trunklines to the CPF - TL-C over a ridge 30 m high - and the inlet separator HPS, three phases, its gas held at 14 barg, its oil and its water each by its level valve.

N09 An oil field gathered, by black oil after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 19 N09 An oil field gathered, by black oil after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its oils#

Each fluid is a black oil with its own figures, in the Fluid window : Kind Black oil, then its oil's gravity, its gas's, its GOR, its water cut and its water's salinity, by correlations (A) or by its PVT table (B). Where lines of different oils meet, FlowMax blends them by their stock-tank volumes, and the Run says so.

Table 31 The black oils of its fluids
FluidWayOil (API)Gas (air = 1)GOR (Sm³/Sm³)Water cut (%)Salinity (ppm)
A-1A, Standing32.00.76090.05.080 000
A-2A, Standing32.00.760110.020.080 000
A-3A, Standing32.00.76085.035.080 000
A-4A, Standing32.00.760130.010.080 000
A-5A, Standing32.00.760100.050.080 000
B-1A, Vasquez-Beggs40.00.820180.00.040 000
B-2A, Vasquez-Beggs40.00.820220.08.040 000
B-3A, Vasquez-Beggs40.00.820250.015.040 000
B-4A, Vasquez-Beggs40.00.820200.025.040 000
C-1B, its table at 85 °C27.00.72050.030.0120 000
C-2B, its table at 85 °C27.00.72060.045.0120 000
C-3B, its table at 85 °C27.00.72045.060.0120 000

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 32 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
A-1Inlet27.4980.004.200E40.3131
A-2Inlet25.3980.003.500E40.1828
A-3Inlet24.7280.002.800E40.0814
A-4Inlet28.2580.005.000E40.3177
A-5Inlet24.5780.003.000E40.0571
B-1Inlet42.0090.004.299E40.2970.5425
B-2Inlet38.0090.003.621E40.4467
B-3Inlet45.0090.005.396E40.3767
B-4Inlet36.0090.003.951E40.2382
C-1Inlet19.4670.002.500E40.0585
C-2Inlet20.0870.003.000E40.0406
C-3Inlet19.3170.002.000E40.0168
GASOutlet14.0067.344.614E41.1351.0000
OILOutlet4.00067.982.890E50.0440
PWOutlet2.00067.689.753E40.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 33 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
CK-A14.200E40.719100.080.020.3147
CK-A23.500E40.538100.080.010.1833
CK-A32.800E40.245100.080.010.0815
CK-A45.000E41.262100.080.010.3196
CK-A53.000E40.261100.080.010.0572
CK-B14.299E412.60100.089.790.5700
CK-B23.621E47.080100.089.840.4567
CK-B35.396E413.77100.089.670.3915
CK-B43.951E46.989100.089.960.2439
CK-C12.500E40.163100.070.010.0586
CK-C23.000E40.219100.070.010.0406
CK-C32.000E40.069100.070.000.0168
LV-12.890E59.29961.3967.940.0406
LV-29.753E412.0431.8467.680.0000
Table 34 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
HPS3 phases14.1667.404.616E43.865E5

What the Run says#

What to retain#

Each well its own oil#

The Fluid window, Fluids tab : each of the twelve wells is a fluid of its own, its Kind Black oil. B-2 takes its reservoir's oil - 40 API, its gas 0.82, by Vasquez-Beggs - and its own GOR, 220 Sm³/Sm³, and water cut, 8 %. A new well of the same reservoir starts as a Copy of one of them, its GOR and its water cut then typed. C-1 to C-3 take way B : their reservoir's PVT table, typed or read from a PVT file.

The Fluid window : B-2, a black oil of its own - its oil, its gas, its GOR and its water cut.
Figure 20 The Fluid window : B-2, a black oil of its own - its oil, its gas, its GOR and its water cut.

B-1 is given its flowing wellhead pressure : in its window, Given Pressure, 42 barg and its temperature. Its rate is the result - 42986 kg/h through its choke and its line. A and C wells are given their test rates instead, Given Flow, their wellhead pressures the results.

B-1 : an inlet stream given its pressure ; its flow is the result.
Figure 21 B-1 : an inlet stream given its pressure ; its flow is the result.

The node labels Name and Given (P / F) on the sheet : P where a stream is given its pressure, F where it is given its flow.

N09 with the node label Given : the A and C wells F, the B wells P, the outlets P.
Figure 22 N09 with the node label Given : the A and C wells F, the B wells P, the outlets P.

N10 A city gas grid of 760 pipes#

A looped distribution grid of 400 nodes and 760 pipes, fed at one corner with 72 000 kg/h of methane and held at its far corner : the size of a town's network. It shows that the gas mode solves a large looped network as quickly as a small one, and how to read it - the pressure falling across the grid, the flows sharing themselves between the loops.

N10 A city gas grid of 760 pipes after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 23 N10 A city gas grid of 760 pipes after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 35 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
G0-0Inlet41.1920.007.200E490.111.0000
G19-19Outlet39.0020.007.200E490.111.0000

What the Run says#

What to retain#

F01 LNG boil-off gas#

The boil-off of an LNG tank at -155 °C through an insulated line to the two-stage BOG compressor, each stage with its cooler, to the fuel gas header. Very cold gas warms in the line ; the tank's pressure follows from the compression.

F01 LNG boil-off gas after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 24 F01 LNG boil-off gas after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 36 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
TANKInlet0.283-155.01.200E413.981.0000
FUELOutlet8.00035.001.200E413.981.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 37 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-1Ratio0.2222.6933.000314.3-100.8
K-2Ratio2.4698.7362.800762.0140.4
Table 38 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E-11.200E4-100.835.00897.7
E-21.200E4140.435.00-780.7

What the Run says#

What to retain#

F02 The steam system of an LNG plant#

The steam that heats the reboiler of the LNG plant's condensate stabiliser (F10), as a project of its own under IAPWS-IF97 : the boilers raising steam to the high-pressure header, the pressure-reducing station to the low-pressure header, the flow control valve of the reboiler, the reboiler condensing the steam, and the condensate back through its trap. The reboiler's duty is the one the plant's Run gives.

F02 The steam system of an LNG plant after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 25 F02 The steam system of an LNG plant after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 39 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
BOILERSInlet40.00400.081829.1191.0000
CONDENSATE RETURNOutlet0.500111.681820.0560

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 40 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
R-STB8182371.5140.8-5954
Table 41 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
PRV-LP818235.4711.21371.91.0000
FV-RB81820.44485.88371.51.0000
TRAP81823.50010.51111.60.0560

What the Run says#

What to retain#

F03 An NGL column#

A distillation column of 30 stages separating an NGL : five feeds at their own stages, a liquid side draw and a vapour side draw on their lines, three side duties - two coolers and a heater - a total condenser and a reboiler. The column is a separator whose Separate-by is Column : its stages are solved by their own method, the bubble points stage by stage, inside the network's Run ; the bottoms leave by their level valve, the liquid draw by its flow valve.

F03 An NGL column after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 26 F03 An NGL column after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 42 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
SLUG CATCHERInlet13.6240.0080000.0000
SCRUBBERSInlet13.6530.0050000.0000
LPG RECYCLEInlet13.6935.0040000.0000
STABILISERInlet13.7355.0030000.0000
DEETHANISERInlet13.7970.0060000.0000
C3 PRODUCTOutlet13.5036.0557900.0025
C5+ PRODUCTOutlet8.000110.41.721E40.3637
SIDE LPGOutlet8.00040.6920000.2692
SIDE VAPOUROutlet12.50104.810000.3341.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 43 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-1011.721E45.36632.04110.40.2397
FV-10120005.33930.6540.690.1817
Table 44 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
C-101Column13.5146.3402.600E4

What the Run says#

What to retain#

F04 NGL recovery, the gas subcooled process (GSP)#

The gas subcooled process of NGL recovery. 100 000 kg/h of rich gas at 75 barg and 25 °C is chilled to -4 °C in E5, then to -30 °C in a three-sided exchanger against the cold residue gas and the column's side reboiler, into the cold separator SEP-1. Its gas is split : 52 000 kg/h through the turboexpander K1, from 70 to 26 barg and down to -70 °C, into the demethanizer at stage 3 ; 10 000 kg/h condensed and subcooled to -79 °C in E1 against the column's overhead and let down by Valve3 onto its top tray at -94 °C - the subcooled reflux that gives the process its name. The separator's liquid is let down by Valve2 to stage 15. The demethanizer SEP-2 is a column of 30 stages at 25 barg with its reboiler, its bottoms held to 1 % methane ; its side reboiler draws 20 000 kg/h of liquid at stage 20 through E7 and returns it to stage 21. The residue gas warms in E1 and the exchanger, is recompressed by K2 and K3 to 70 barg and cooled to 35 °C in E4 ; the NGL, 33 000 kg/h, leaves by its level valve at 20 barg.

F04 NGL recovery, the gas subcooled process (GSP) after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 27 F04 NGL recovery, the gas subcooled process (GSP) after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 45 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
N8Outlet20.0033.053.302E40.1121
N23Outlet70.0034.826.698E480.571.0000
N24Inlet75.0825.001.000E596.481.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 46 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K1Pressure set70.0025.720.376-702.5-70.45
K2Pressure set21.1931.081.445118324.61
K3Pressure set30.0071.572.3413318108.2
Table 47 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E110000-31.53-78.99-844.3
E26.698E4-79.99-63.72844.3
E36.698E4-64.60-6.9162590
E46.698E4108.135.00-3656
E51.000E524.66-4.000-2917
E61.000E5-4.310-30.00-3532
E72.000E4-48.31-5.000941.6
Table 48 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
Valve13.302E44.86150.1533.050.1121
Valve23.802E444.8849.90-56.630.4637
Valve31000041.8350.20-92.220.1936
Table 49 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
SEP-12 phases72.16-30.246.198E43.802E4
SEP-2Column25.00-61.946.187E45.813E4

What the Run says#

What to retain#

F05 A dew point plant#

A wet rich gas under CPA : the inlet separator and its free water, the glycol unit as a splitter, the gas-gas exchanger, the chiller, the low temperature separator and its NGL, the cold gas back to the sales line. Two probes at the sales gas give its water and hydrocarbon dew points.

F05 A dew point plant after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 28 F05 A dew point plant after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 50 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
FEEDInlet67.0940.001.000E596.280.9836
SALESOutlet66.0031.598.460E487.461.0000
DRAINOutlet5.00041.1214180.0011
TEG WATEROutlet2.00041.33113.90.0000
NGLOutlet20.00-22.361.387E40.3352

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 51 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E-1H9.847E439.9711.94-2433
E-29.847E411.94-5.054-1734
E-1C8.460E4-5.06331.632433
Table 52 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-1141862.064.1841.120.0011
LV-2113.965.040.8241.330.0000
LV-31.387E445.8216.86-22.060.3319
Table 53 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
IS2 phases67.0639.989.858E41418
TEGSplitter67.0439.989.858E40
LTS2 phases66.33-5.0568.460E41.387E4

What the Run says#

What to retain#

F06 A gas processing train#

A gas processing train in its main steps : separation, treating and recovery modelled by separators and component splitters, with the compression and the exchangers between them. Each splitter is given each component's share to its top ; the rest goes to its bottom.

F06 A gas processing train after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 29 F06 A gas processing train after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 54 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MMSCFD)Vapour fraction
FEEDInlet46.6745.001.500E5144.60.9622
ACIDOutlet1.500-7.7901.829E48.6711.0000
EXPORTOutlet90.0031.541.265E5130.21.0000
TEG WATEROutlet2.00045.92291.80.0000
CONDOutlet10.0025.00000.9629
PWOutlet2.00045.7049130.0013

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 55 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-1Ratio46.3993.802.0004271107.4
Table 56 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
AC1.265E5107.445.00-6058
Table 57 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-31.829E444.6015.30-7.7901.0000
LV-4291.844.422.5445.920.0000
LV-1036.540.0000.9592
LV-2491344.528.5645.700.0013
Table 58 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
IS3 phases46.5445.001.451E54913
AGRSplitter46.4745.001.451E50
TEGSplitter46.4245.001.268E50

What the Run says#

What to retain#

F07 Compression and its cooling water#

A lean gas compressed in two stages, its intercooler and aftercooler exchanger pairs with the cooling water - the same fluid package for both - and the cooling water circuit itself : the tower basin, the pump, the supply and return headers at their heights, up to the tower's distributor.

F07 Compression and its cooling water after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 30 F07 Compression and its cooling water after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 59 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
SUCTIONInlet19.2835.008.000E42.5051.0000
EXPORTOutlet95.0052.558.000E42.5051.0000
DRAINOutlet2.00025.00001.0000
BASINInlet030.009.818E50.0000
TOWEROutlet036.109.818E50.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 60 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-1Ratio19.2543.562.2003295106.7
K-2Ratio42.9995.802.2003334123.1
Table 61 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
E-1H8.000E4106.748.83-3157
E-2H8.000E4123.052.57-4267
E-1C4.924E530.0235.173157
E-2C4.894E530.0237.024267
Table 62 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-1041.010.0001.0000
Table 63 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
KO2 phases43.0148.828.000E40
Table 64 The pumps
NameMass flow (kg/h)Pressure rise (bar)Power (kW)Outlet temperature (°C)
P-CW9.818E52.40630.02

What the Run says#

What to retain#

F08 A water and steam loop#

A whole steam and water loop under IAPWS-IF97 : the deaerator, two feed pumps on their curves (one standby), the boiler raising superheated steam at 40 barg and 400 °C, a turbine valve, two letdown stations with a desuperheater to the medium and low pressure headers, an insulated main that loses heat and its drip pot, a heater condensing its steam, and the condensate back through its traps to the condensate tank. It teaches the method of properties for water, the letdown of superheated steam, mixing water into steam, and condensation where heat is lost.

F08 A water and steam loop after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 31 F08 A water and steam loop after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 65 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
DAInlet1.500127.02.702E40.0000
TURBOutlet30.00386.01.200E40.3781.0000
MP-2Outlet8.000243.440000.1261.0000
LP-1Outlet3.000234.430000.0941.0000
LP-2Outlet3.375147.120001.0000
DRAINOutlet099.9323.440.0889
CTOutlet0.200105.160000.0142

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 66 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
BLR2.552E4127.8400.01.884E4
E-M16000233.4112.6-4100
Table 67 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
FCV-T1.200E418.2920.09386.01.0000
PRV-11.352E438.0350.91369.51.0000
FCV-M160007.46445.62233.41.0000
FCV-M240001.59672.74243.41.0000
FCV-DSH150039.589.48128.50.0000
PRV-250236.38658.06235.31.0000
FCV-L130000.46781.03234.41.0000
TR-123.443.3831.5499.930.0889
TR-260002.028100.0105.10.0142
Table 68 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
DP-12 phases3.383147.1200023.44
Table 69 The pumps
NameMass flow (kg/h)Pressure rise (bar)Power (kW)Outlet temperature (°C)
FP-12.702E447.02127.8

What the Run says#

What to retain#

F09 An oil production facility#

Three wells - 90 000, 70 000 and 40 000 kg/h of well fluid at 80 °C, oil, gas and water - each on its choke and its flowline over the ground to the manifold ; the three-phase HP separator, its water to the produced water, its oil heated and let down to the MP and LP separators ; the oil pumped 2 km to export ; the LP and MP gas recompressed in two stages into the HP gas ; and that gas compressed again for export and sent 20 km. The wells' pressures follow from their chokes, the flowlines and the plant ; the separators' pressures from the gas export and the compressors' ratios.

F09 An oil production facility after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 32 F09 An oil production facility after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 70 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
W-1Inlet39.0480.009.000E40.3419
W-2Inlet36.3480.007.000E40.3494
W-3Inlet31.2580.004.000E40.3641
GAS EXPORTOutlet75.0045.004.521E41.0620.9376
PWOutlet0.50079.622.285E40.0000
DRAINOutlet0.5001.91375280.3867
OILOutlet15.0079.391.244E50.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 71 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
K-EXRatio24.9776.933.0002199164.7
K-3Ratio1.1496.3373.400155.0129.4
K-2Ratio6.22425.043.600376.4132.1
Table 72 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
AC-EX4.521E4164.745.00-4486
H-11.375E575.3085.001008
AC-35883129.440.00-669.8
AC-21.037E4132.140.00-1022
Table 73 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
CH-19.000E44.725100.078.920.3558
CH-27.000E43.061100.079.260.3585
CH-34.000E41.161100.079.670.3677
LV-11.375E517.9531.7575.300.1220
LV-42.285E424.4918.3479.620.0000
LV-21.303E54.18361.7681.150.0629
LV-527625.28717.6843.280.1317
LV-6476624.0515.55-6.5870.4033
LV-31.244E52.01483.5279.340.0000
Table 74 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
HP3 phases25.1379.153.961E41.604E5
MP2 phases6.25384.6372471.303E5
LP2 phases1.15078.4258831.244E5
S22 phases6.22757.341.037E42762
S12 phases25.0040.0056024766
Table 75 The pumps
NameMass flow (kg/h)Pressure rise (bar)Power (kW)Outlet temperature (°C)
P-OIL1.244E516.5679.26

What the Run says#

What to retain#

Late in its life : a fluid by its GOR and its water cut#

As a field ages its wells make more water and, below their bubble point in the reservoir, more gas. The well fluid of F09 has a GOR of 270 Sm³/Sm³ and a water cut of 11.7 %, read at 15 °C and 1.01325 bar. W-3 is now tested at a GOR of 410 and 40 % water. In the Fluid window, Fluids tab, GOR and water... makes that fluid from the well fluid : its gas taken as many times as the GOR asks for its oil, its water as the water cut asks, flashed again until it reads back what was asked.

GOR and water : the fluid made from the well fluid at a GOR of 410 and 40 % water.
Figure 33 GOR and water : the fluid made from the well fluid at a GOR of 410 and 40 % water.

The new fluid, Well fluid, late life, reads back a GOR of 410.0 and 40.0 % water. Given to W-3 - its stream's fluid - the plant is run again ; W-3 still makes 40000 kg/h, but more of it is water and gas :

Table 76 F09 as it is, and with W-3 late in its life
As it isW-3 late in lifeDifference
W-1, pressure (barg)39.039.10.1 %
W-2, pressure (barg)36.336.40.1 %
W-3, pressure (barg)31.330.9-1.3 %
HP, pressure (barg)25.125.20.1 %
MP, pressure (barg)6.36.2-0.1 %
LP, pressure (barg)1.11.1-0.6 %
Gas export (kg/h)45212.846756.03.4 %
Oil export (kg/h)124407.6114061.7-8.3 %
Produced water (kg/h)22851.332498.442.2 %
K-EX, power (kW)2199.02263.72.9 %
K-2, power (kW)376.4326.2-13.3 %
K-3, power (kW)155.0141.3-8.8 %

The water to the produced-water line rises by 9647 kg/h and the oil to export falls by 10346 kg/h ; the export compressor takes 65 kW more for the gas.

Its wells by black oil#

Black oil is the usual model for wells and flowlines. F09's wells, chokes and flowlines into its HP separator are built again here and run twice : with the well fluid's composition, then with the well fluid made a black oil from that composition - the Fluid window, Kind Black oil, way C, its tables at 80 °C. Way C reads it as an oil of 73.3 API, its gas 0.917, a GOR of 267 Sm³/Sm³ and 11.5 % water.

Table 77 F09's wells by composition and by black oil
CompositionBlack oilDifference
W-1, pressure (barg)38.9939.170.5 %
W-2, pressure (barg)36.2836.420.4 %
W-3, pressure (barg)31.1931.250.2 %
FL-1, pressure drop (bar)8.378.440.8 %
FL-1, liquid holdup0.230.23-0.6 %
FL-3, liquid holdup0.210.21-0.4 %
HP, temperature (°C)79.1579.780.8 %
HP gas (kg/h)39654.7240321.241.7 %
HP oil (kg/h)137495.77136541.51-0.7 %
HP water (kg/h)22849.5123137.251.3 %

The wellhead pressures agree within 0.5 %, the flowlines' drops and holdups within 0.8 % : for wells and their lines black oil does well, and it solves in 1.6 s for the composition's 1.6 s. The separator's split differs more - its gas by 2 % : the black oil's tables are those of 80 °C and its gas is of one composition whatever the pressure, where the composition flashes each component at the separator's own conditions.

The plant itself stays a project of compositions. Run as a black oil, its heater, its three stages of separation and its compression ask what tables made at one temperature cannot give : this oil is light - its stock-tank oil near 70 API - and it changes across each stage. Black oil suits the oils of N09 ; for a light oil through a plant, the composition.

F10 An LNG plant with its utilities#

A whole plant, 300 t/h of well fluid : the inlet facility and the condensate stabiliser, the acid gas removal and the dehydration, the NGL recovery by a turboexpander and its demethanizer, the LPG fractionation (deethanizer, depropanizer, debutanizer), then the LNG train - the propane precooler, the main cryogenic exchanger, the end flash drum and the tank. Beside it, its utilities as networks of their own fluids : the cooling water from the tower basin through its pump to three coolers and back, and the propane refrigeration circuit - its compressor, its condenser on the cooling water, its two letdowns to the chiller and the precooler. Five exchangers are the two sides of one across the networks. It was built and solved by parts first, each ended by an outlet at the pressure the next part takes, and the utilities alone with the process's duties given - then all together. The steam of the stabiliser's reboiler is a project of its own under IAPWS-IF97, F02.

F10 An LNG plant with its utilities after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.
Figure 34 F10 An LNG plant with its utilities after its Run : the names, the mass flow (kg/h) on the links, the pressure (barg) at the nodes.

Its streams#

Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.

Table 78 The streams
NameKindPressure (barg)Temperature (°C)Stream flow (kg/h)Std gas flow (MSm³/d)Vapour fraction
FEEDInlet70.5650.003.000E57.0580.8703
FUEL GASOutlet8.000139.81.100E40.2221.0000
CONDENSATEOutlet3.00040.003.965E40.0000
PRODUCED WATEROutlet2.00051.311.421E40.0000
ACID GASOutlet1.500-43.442.290E40.3031.0000
DH WATEROutlet2.00051.30343.30.0000
ETHANEOutlet20.00-64.2498020.0000
PROPANEOutlet14.00-63.901.802E40.0000
BUTANEOutlet5.000-63.351.294E40.0000
GASOLINEOutlet2.000-63.161.603E40.0000
LP FUELOutlet1.000-153.869210.2220.9989
LNG TANKOutlet0.150-160.41.482E50.0525
BASINInlet030.007.345E60.0000
TOWEROutlet034.347.345E60.0000
C3 SUCTIONInlet0.100-38.002.475E53.1851.0000
C3 RETURN AOutlet0.100-35.589.459E41.2171.0000
C3 RETURN BOutlet0.100-35.571.529E51.9671.0000

Its equipment#

The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).

Table 79 The compressors and expanders
NameSpecificationInlet pressure (barg)Outlet pressure (barg)Pressure ratioPower (kW)Outlet temperature (°C)
X-1Ratio69.3630.660.450-1668-70.30
K-RCRatio30.4668.232.2007277126.8
K-C3Pressure set0.09414.6014.1071.114E478.96
Table 80 The exchangers
NameMass flow (kg/h)Inlet temperature (°C)Outlet temperature (°C)Duty (kW)
H-STB5.064E433.48140.05954
E-COND3.965E4123.840.00-2770
E-GGH2.119E549.91-11.30-1.206E4
E-C3H2.119E5-11.30-35.00-5912
E-GGC1.551E5-64.8248.841.206E4
AC-RC1.551E5126.840.00-9887
E-PRE1.551E540.00-35.00-9555
E-MCHE1.551E5-35.00-150.0-2.486E4
AC-RCC3.395E630.0432.419887
E-CONDC5.537E530.0434.082770
C3-CONDC3.396E630.0436.292.637E4
C3-COND2.475E578.9540.00-2.637E4
E-C3C9.459E4-39.64-35.585912
E-PREC1.529E5-39.02-35.569555
Table 81 The valves
NameMass flow (kg/h)Pressure drop (bar)Opening (%)Outlet temperature (°C)Vapour fraction
LV-SC15.064E461.612.5233.530.3750
LV-STB3.965E44.4369.88124.30.1803
LV-SC21.421E468.271.0151.310.0000
LV-AGR2.290E468.553.33-43.011.0000
LV-DH343.368.270.2451.300.0000
LV-CS6.543E438.616.11-53.980.3497
LV-DM5.680E410.618.56-64.250.0000
LV-DE4.699E45.83414.05-63.910.0000
LV-DP2.898E48.9939.08-63.360.0000
LV-DB1.603E42.85913.11-63.170.0000
JT1.551E565.83100.0-152.60.0370
LV-LNG1.482E51.22915.91-159.90.0491
JT-C3A9.459E414.2510.81-39.610.4802
JT-C3B1.529E514.2117.50-38.940.4775
Table 82 The separators
NameTypePressure (barg)Temperature (°C)Gas through (kg/h)Liquids through (kg/h)
SC3 phases70.2949.922.351E56.485E4
STBSplitter8.096139.93.865E41.199E4
AGRSplitter70.2849.922.351E55.594
DHSplitter70.2749.912.114E5837.8
CS2 phases69.36-35.001.465E56.543E4
DMSplitter30.65-64.811.362E57.566E4
DESplitter20.00-64.2405.680E4
DPSplitter14.07-63.9004.699E4
DBSplitter5.035-63.3502.898E4
EFD2 phases1.009-153.769211.482E5
Table 83 The pumps
NameMass flow (kg/h)Pressure rise (bar)Power (kW)Outlet temperature (°C)
P-CW7.345E63.73530.04

What the Run says#

What to retain#