1 Introduction#

FlowMax's Gas & Multiphase mode calculates networks of gas, of gas and liquid together, and of water and steam, in steady state: the pressure and the temperature at every node, the flow, the phases and the velocity in every link, the duty of every exchanger and the power of every machine. A fluid is a composition worked out by an equation of state, or a black oil worked out from its field figures.

This guide is a reference. It goes through the mode window by window and says what each field means and what each command does. It works no example: the Gas Training Manual does that, with twenty complete networks and facilities and their project files. Drawing a model - the sheet, the pipes, the nodes, the labels - is the same in every mode and is in the Steady State User Guide.

Table 1 What the gas mode does
SubjectWhat FlowMax offers
FluidsCompositions from a library of 27 components and hypothetical ones, by Peng-Robinson, SRK, CPA, GERG-2008, Span-Wagner (CO2) or IAPWS-IF97 (water and steam) ; several fluids a project ; black oils by correlations, PVT tables or a composition
StreamsInlets and outlets, each given its flow or its pressure ; a temperature, a superheat or a quality
PipesGas, two phases by Beggs and Brill or no slip, isothermal, adiabatic or exchanging heat with the ground or the sea ; a profile of the ground ; connectors without loss
EquipmentValves held at a flow, a pressure or a drop ; compressors and expanders on a ratio, a power or their curve ; pumps ; pressure drops, orifices ; exchangers, one side or two
SeparationSeparators of two or three phases with their level valves or pumps and carryover ; splitters by component ; distillation columns of stages
ResultsTables of links and nodes, tables on the sheet, the heat and material balance, property probes (hydrate, dew points, heating values ...), the colour rule

2 Installation and licence#

2.1 System requirements#

Table 2 What FlowMax needs
ItemRequirement
Operating systemWindows 10 or Windows 11, 64-bit
ProcessorDual core, 1.8 GHz or faster
Memory4 GB; 8 GB recommended
Disk1 GB free
Screen1280 x 768 or larger
InternetNeeded to activate the licence, unless an offline file is used

2.2 Installing#

  1. Start the Flowmax Setup application.
  2. Read the information of the first page and press Next if you agree.
  3. Choose whether a shortcut is put on the desktop.
  4. Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.

2.3 Activating the licence#

The first time FlowMax starts it shows the licence window.

FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.

What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.

2.4 Help and examples#

The File menu holds them, for the mode the project is in:

The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.

3 The gas mode#

3.1 A new gas project#

File > New opens the start window. Its two cards choose the mode of the project: Liquid - water, oil, fire water, in steady state and transient - or Gas / multiphase. The gas card opens an empty sheet in the gas mode with methane as its fluid, the flows in kg/h and the pressures in barg; the Fluid window and the Settings change them. A project keeps its mode: a gas project opens as one.

The start window : the mode of a new project.
Figure 1 The start window : the mode of a new project.

3.2 The window in the gas mode#

The main window in the gas mode, N01 solved : its Home page, the Equipment panel, the sheet.
Figure 2 The main window in the gas mode, N01 solved : its Home page, the Equipment panel, the sheet.
Table 3 The Home page in the gas mode
CommandWhat it does
RunSolves the network : chapter 11 for what it gives, chapter 13 for what it says
Scenario CaseThe case the sheet shows, when there are several
CalculationHydraulics + HMB : every pressure loss. HMB only : the pipes taken without their pressure loss - the flows, the separators, the temperatures and the balance as ever, in a second ; the pressures are not those of a full Run. The status bar then says Solved - HMB only
FluidThe Fluid window : chapter 4
Units, SettingThe units and the Settings : chapter 12
Links, Nodes, GraphsThe tables of the links and of the nodes, the charts : chapter 11
Grid, Energy lines, Setting colorsThe sheet's grid ; the dashed line between the two sides of an exchanger ; the colour rule

The Equipment panel holds what a gas network is made of: pipes and their bends, inlet and outlet streams, valves, pumps, compressors, pressure drops and exchangers, the separator, tees and reducers, text, notes and tables. The Transient page is not in the gas mode.

The Reports page : the report, the datasheet, the Property probe and the H&MB.
Figure 3 The Reports page : the report, the datasheet, the Property probe and the H&MB.

3.3 The order of work#

  1. Fluid : the components and the package, then each fluid of the project (chapter 4).
  2. Draw the network. Make the ends Inlet and Outlet streams and give each its flow or its pressure (chapter 5).
  3. Give each pipe its size and how it exchanges heat (chapter 6), each valve and machine its specification (chapters 7 and 8).
  4. Make the separators, their outlets and their level valves (chapter 10).
  5. Run. Read the sheet, the tables, the H&MB and the probes (chapter 11), and what the Run says (chapter 13).

Before a run A missing input is listed beside the status bar, as in the liquid mode. A gas network needs at least one node at a given pressure : an outlet, or an inlet given its pressure.

4 Fluids#

Fluid on the Home page opens the Fluid window. It has two tabs: Components and package, one list of components and one equation of state for the whole project, and Fluids, the fluids of the project made from them.

4.1 Components and package#

Components and package : N07's list of components, by Peng-Robinson.
Figure 4 Components and package : N07's list of components, by Peng-Robinson.
Table 4 The fluid packages
PackageFor
Peng-RobinsonNatural gas, condensate, oil : the usual choice
SRKThe same, the older equation
CPA (water, glycols)Fluids with water, methanol, MEG or TEG : their association is in it
Span-Wagner (pure CO2)CO2 alone, its reference equation ; other fluids of the project by Peng-Robinson
IAPWS-IF97 (water and steam)Water alone, its industrial standard ; other fluids by CPA
GERG-2008 (gas, one phase)Natural gases of one phase, the reference for custody transfer ; where a fluid condenses, Peng-Robinson is the better choice and the Run says so

4.2 Fluids#

The Fluids tab : N07's two fluids, the volatile oil chosen.
Figure 5 The Fluids tab : N07's two fluids, the volatile oil chosen.
Table 5 The Fluids tab
FieldMeaning
Fluids, New, Copy, Rename, RemoveThe fluids of the project. A project keeps one at least. A stream names the fluid it brings
Composition of ..., by Mole / MassIts fractions, mole or mass. Click a cell and type ; a column copied from a sheet pastes with Ctrl+V on its first cell
Normalize, TotalBrings the fractions to a total of 1
Fluid model (at the top)Composition : every fluid of the project a composition. Black oil : every fluid a black oil (section 4.4)
At 15 °C, 1.01325 barIts molar mass, the density of its gas and its phases at standard conditions, worked out as it is typed
GOR and water...A new fluid made from this one at the GOR and the water asked (section 4.3)

Confirm checks every fluid - fractions that add up to 1, a black oil's figures - and offers IAPWS-IF97 or CPA when a fluid mostly of water is given to Peng-Robinson or SRK. A stream whose fluid was renamed follows it; one whose fluid was removed takes the first.

4.3 GOR and water : a fluid made from another#

As a field ages its wells make more water and more gas. GOR and water... makes a new fluid from a fluid of the project at the gas-oil ratio and the water asked: the fluid is flashed at 15 °C and 1.01325 bar, its gas taken as many times as the GOR asks for its oil, its water as the water cut (or the WOR) asks, and flashed again until it reads back what was asked. The fluid must have an oil at standard conditions, and water among its components when water is asked.

GOR and water : the window, its fluid's own figures shown above.
Figure 6 GOR and water : the window, its fluid's own figures shown above.
Table 6 GOR and water
FieldMeaning
From the fluidThe fluid it is made from ; its GOR and water cut at standard conditions shown under it
GORSm³ of gas a Sm³ of oil, at standard conditions
Water cut, WORThe water, % of the liquid by volume, or Sm³ of water a Sm³ of oil
NameThe new fluid's name, made from the figures until it is typed
Make the fluidAdds it to the list, chosen ; Confirm the Fluid window to keep it

4.4 Black oil#

A black oil is a fluid of three pseudo-components - the stock-tank oil, its gas, its water - whose properties come from the field's figures instead of an equation of state: the gas in solution and the bubble point, the oil's volume factor and viscosity, the gas's Z and viscosity, the water's density and viscosity. A project is all compositions or all black oils : Fluid model, at the top of the window. In a black-oil project each fluid has its own figures - in an oil field each well its oil, its GOR and its water cut - and its Kind : Oil, its gas and water, or Gas alone, a fuel gas or a lift gas.

Way A : N09's well B-2, its reservoir's oil by Vasquez-Beggs, its own GOR and water cut.
Figure 7 Way A : N09's well B-2, its reservoir's oil by Vasquez-Beggs, its own GOR and water cut.
Table 7 A black oil
FieldMeaning
Oil gravityAPI
Gas specific gravityAir = 1
Gas-oil ratio, GORSm³/Sm³ : all its gas at standard conditions over its stock-tank oil
Water cut% of the liquid by volume at standard conditions
Water salinityppm by mass ; 0 : fresh water
A : CorrelationsStanding, Vasquez-Beggs or Glaso for the gas in solution, the bubble point and the volume factor ; the viscosity by Beggs-Robinson
B : its PVT tableA row a pressure : bara, the gas in solution Rs (Sm³/Sm³), Bo, the oil's viscosity (cP), Bg (rm³/Sm³), the gas's viscosity (cP), to the bubble point ; At its temperature. Read a PVT file... reads PVTO, PVTG or PVDG, PVTW, DENSITY and RTEMP, METRIC or FIELD
C : from a compositionIts own composition, typed by Composition... on the components of the first tab (Components : for C), At a temperature, Make its tables : the whole fluid's gas and oil at each pressure to its bubble point, over its stock-tank oil ; its GOR and water cut with them
Gas aloneIts gravity alone : A by Hall-Yarborough's Z and Lee-Gonzalez-Eakin's viscosity, or B its table of Bg and viscosity against pressure
Way B : N09's well C-1, its reservoir's PVT table.
Figure 8 Way B : N09's well C-1, its reservoir's PVT table.
Way C : N07 made a black-oil project at 60 °C - its volatile oil from its own composition.
Figure 9 Way C : N07 made a black-oil project at 60 °C - its volatile oil from its own composition.
A gas alone : N07's gas condensate, its gravity.
Figure 10 A gas alone : N07's gas condensate, its gravity.

Changing the fluid model#

5 Streams#

The ends of a network are streams: Inlet and Outlet on the Equipment panel, a tag pointing the way the gas goes. An inlet brings a fluid into the network, an outlet takes it out. Each is given its flow or its pressure ; what is not given is the result. A double-click opens its window ; on a node that is neither, the window shows its name, elevation and results : a junction.

An inlet given its flow : N09's well A-1.
Figure 11 An inlet given its flow : N09's well A-1.
Table 8 The stream window
FieldMeaning
Given : Flow, PressureWhat is given ; the other is the result
Mass flow, Molar flow, Standard volumeAn inlet's flow : kg/h (or the project's unit), kmol/h, or Sm³/h at 15 °C and 1 atm (23.645 m³/kmol)
PressureIts pressure, in the project's unit
Temperature, Superheat, QualityAn inlet's temperature ; or, for a fluid of one component (water, CO2), its superheat in K above its saturation at its own pressure, or its quality, % of vapour by mass
FluidThe fluid it brings ; Fluids... opens the Fluid window
An outlet's flowA mass flow leaving
ResultsAfter a Run : the pressure or the flow not given, its vapour fraction, the fluids of an outlet's mix
An inlet given its pressure : N09's well B-1 at its flowing wellhead pressure ; its rate is the result.
Figure 12 An inlet given its pressure : N09's well B-1 at its flowing wellhead pressure ; its rate is the result.
An outlet given its pressure : N09's GAS.
Figure 13 An outlet given its pressure : N09's GAS.
An outlet given its flow.
Figure 14 An outlet given its flow.

The node label Given (P / F) shows on the sheet which each stream is given : P its pressure, F its flow. Choose it in the node label lists of the Home page, as Name or Pressure.

N09 with the node labels Name and Given (P / F).
Figure 15 N09 with the node labels Name and Given (P / F).

6 Pipes#

The pipe window of the gas mode has the liquid mode's rows - name, length, schedule, size, material, roughness, fittings, status - and four of its own : the route, the temperature along the pipe, the two-phase flow and the connector.

N09's trunkline TL-C : its route by its profile, heat to the ground, Beggs and Brill.
Figure 16 N09's trunkline TL-C : its route by its profile, heat to the ground, Beggs and Brill.
Table 9 The gas pipe
FieldMeaning
Route : Length, ProfileIts length typed, or its profile of distances and elevations on the Profile tab
IsothermalThe temperature stays as it comes in
AdiabaticNo heat exchanged : the gas cools as it expands (Joule-Thomson)
Heat to the surroundingsThe heat it gives to the surroundings at the Ambient temperature, through U, overall on its inside area
Two-phase flow : ModelBeggs & Brill : the liquid holdup and the flow pattern, by the pipe's inclination ; Homogeneous (no slip) : gas and liquid as one fluid
SegmentsThe pipe is marched in this many segments (4 to 200)
Eq. lengthIts fittings as a length of pipe ; a K factor as well, both count
No pressure lossA connector : its two ends at one pressure, drawn dashed ; its length, bore and fittings left out
The Profile tab : the ground, and along it after a Run the pressure, the temperature or the liquid holdup.
Figure 17 The Profile tab : the ground, and along it after a Run the pressure, the temperature or the liquid holdup.

The Profile tab takes distances and elevations, its two ends those of its nodes ; Show draws the elevation, the pressure, the temperature or the liquid holdup along it, and the table under it gives each at the end of each segment.

The U window : typical values worked out for this pipe, or U from its layers.
Figure 18 The U window : typical values worked out for this pipe, or U from its layers.

The ? beside U opens the U window : six typical cases worked out for this pipe's size - bare in air or in sea water, concrete-coated, polypropylene-coated, buried, insulated - and an estimate from its layers, from the steel out, and what surrounds it : air, water or the ground. Use writes the value into the pipe.

7 Valves#

A valve's Specification box says what holds it ; its opening is then the result. In a Run of the liquid mode's steady state the same box is used.

N01's PCV-1 : held at the pressure downstream.
Figure 19 N01's PCV-1 : held at the pressure downstream.
Table 10 A valve's specification
FieldMeaning
Flow setA flow, through itself or another link ; Pick... chooses the link
Pressure setA pressure at a node : its downstream, its upstream or another anywhere in the network ; Pick... chooses the node
Drop setThe pressure drop across it
RatingIts opening, % : its flow is the result
Cv, Kv ; Valve typeIts capacity, and its characteristic : linear, equal percentage, quick opening or a curve of its own
xTThe drop ratio at which a gas chokes through it (IEC 60534) ; 0.72 when not given
No reverse flowA check : it shuts against a flow the other way
N01's FCV-1 : held at the flow of its user.
Figure 20 N01's FCV-1 : held at the flow of its user.
A choke : N09's CK-B1 on its rating.
Figure 21 A choke : N09's CK-B1 on its rating.
A level-control valve : N09's LV-1, the liquid of the separator HPS.
Figure 22 A level-control valve : N09's LV-1, the liquid of the separator HPS.

A valve chosen in a separator's Level control is that separator's level valve : its title says so, its specification is frozen, its flow is the separator's liquid and its opening the result.

8 Compressors, expanders and pumps#

8.1 Compressors and expanders#

A compressor is drawn with its own symbol from the Equipment panel. Its window :

F07's K-1 on its pressure ratio.
Figure 23 F07's K-1 on its pressure ratio.
Table 11 The compressor
FieldMeaning
Flow setIts own flow : the ratio it needs is the result
Pressure setA pressure at a node - its suction, its discharge or another : the ratio it needs is the result
Rating, by Pressure ratioIts ratio, outlet over inlet, absolute. Below 1 it is an expander, which gives power
Rating, by PowerThe power it takes
Rating, by CurveIts curve at rated speed - actual inlet flow, head, efficiency - and its speed, % of rated ; other speeds by the fan laws. Outside its first and last points the Run says : surge, stonewall
EfficiencyPolytropic or Isentropic, % ; on its curve, the curve's
ResultsIts power (an expander's : the power it gives) and its outlet temperature
A compressor on its curve : five points at rated speed, its surge and stonewall marked.
Figure 24 A compressor on its curve : five points at rated speed, its surge and stonewall marked.
F04's turboexpander X-1 : a ratio below 1.
Figure 25 F04's turboexpander X-1 : a ratio below 1.

8.2 Pumps#

F09's oil pump P-OIL on its curve.
Figure 26 F09's oil pump P-OIL on its curve.

9 Pressure drops, orifices and exchangers#

N01's filter FLT, a pressure drop.
Figure 27 N01's filter FLT, a pressure drop.
Table 12 A pressure drop
FieldMeaning
Calculate KFrom a reference flow and its pressure drop : DP = K Flow^n
Specify KK and n typed
Fixed PDOne pressure drop whatever the flow
PQ CurveIts drop against its flow
OrificeOn a flow element : its bore, the pipe at its inlet ; ISO 5167-2 - the pressure taps (flange, corner, D and D/2), β, its discharge coefficient and expansibility, its pressure loss, and whether it is choked or outside the standard
Required flow (optional)A flow the element is to pass, for the check of the Run

9.1 An exchanger#

An exchanger is a pressure drop with a Heat Transfer tab : No heat transfer, Fixed duty (positive heats the fluid, negative cools it) or Outlet temperature.

N01's heater HTR : its outlet temperature.
Figure 28 N01's heater HTR : its outlet temperature.

The two sides of one exchanger : in the gas mode a fourth choice, From another exchanger, joins two exchangers of the network as the hot and the cold side of one. Its specification is one of Duty, Hot outlet, Cold outlet, UA or Approach ; the results give the duty, the LMTD and the smallest end difference, and the Run says when the temperatures cross. Merged draws the two as one circle where their lines cross ; Swap the sides exchanges them.

F07's after-cooler, two sides : the hot side.
Figure 29 F07's after-cooler, two sides : the hot side.
Its Heat transfer tab : the two sides, their specification and results.
Figure 30 Its Heat transfer tab : the two sides, their specification and results.

10 Separators, splitters and columns#

A node becomes a separator with the Separator of the Equipment panel. Its window :

N01's knock-out drum KO : two phases.
Figure 31 N01's knock-out drum KO : two phases.
Table 13 The separator
FieldMeaning
PhasesTwo : gas and liquid. Three : gas, oil and water
Separate byPhases : a flash ; Components - a splitter (section 10.1) ; Stages : a column (section 10.2)
OutletsWhich line takes the gas, the liquid (the oil) and the water ; None : it leaves the network here. Primary : the phase that leaves freely, its flow what is left ; the others are held. Given by the height of their far ends until chosen
Level controlThe valve - or the pump - that holds each liquid's level : it passes that liquid, its opening (or its rise) the result
Carryover% of a phase that leaves with another : liquid in the gas, gas in the liquid, water in the oil, oil in the water
ResultsIts pressure, temperature and each phase out ; a level valve's opening, a pump's rise, what a gas line has to spare, the head a liquid line needs
SymbolBy its phases, vertical, horizontal, knock-out drum, horizontal with a water boot
Not a separatorMakes it a node again
N09's inlet separator HPS : three phases, its oil by LV-1, its water by LV-2.
Figure 32 N09's inlet separator HPS : three phases, its oil by LV-1, its water by LV-2.

10.1 A splitter : separated by components#

In the place of an amine unit, a dryer, a membrane : the % of each component that leaves by the top - and the middle, with three - by moles, the bottom the rest ; the outlets at the inlet's temperature or at their own ; its duty the heat its outlets take. A black oil has no components to split.

F04's demethaniser DM as a splitter.
Figure 33 F04's demethaniser DM as a splitter.

10.2 A column of stages#

Stages : a column makes the separator a distillation column, solved stage by stage by its own method inside the network's Run, the phases of each stage by the project's equation of state. Its window gains two tabs.

F03's NGL column : its Column tab and its schematic.
Figure 34 F03's NGL column : its Column tab and its schematic.
Table 14 The Column tab
FieldMeaning
TypeDistillation : a condenser and a reboiler ; Stripper : a reboiler ; Absorber : neither
Stages, CondenserThe number of stages, the condenser the first and the reboiler the last ; a Total condenser gives the top liquid, a Partial one the top vapour
FeedsUp to six : the line and the stage of each
TargetsTwo for a distillation, one for a stripper, none for an absorber : reflux ratio, boil-up ratio, top or bottom rate, a component in the top or the bottom (mol %), a component's recovery, the bottom's RVP. Without a reflux ratio among them FlowMax finds it
Pressure dropNone, total or a stage's ; the top at the node's pressure
Products and resultsThe top and bottom lines ; the duties of the condenser and the reboiler, the top and bottom temperatures, the reflux and boil-up ratios ; Stage profile...
The Sides tab : side draws and side heaters or coolers.
Figure 35 The Sides tab : side draws and side heaters or coolers.
The stage profile after a Run.
Figure 36 The stage profile after a Run.

Its method The column is solved by bubble points stage by stage. A column of wide-boiling feed with a methane-rich top may not converge ; the Run then refuses it and says why, and its separator by components is the fall-back.

11 Results#

11.1 The tables of the links and the nodes#

Links on the Home page lists the links by kind - Pipe, Pump, Compressor, Valve, Pressure drop, Exchanger - with their inputs and the Run's results : for a pipe its pressures, mass, standard and actual flows, velocity, Mach number, ρv², its pressure drop split into friction and static, its temperatures, vapour fraction, holdup, flow pattern and heat lost ; for a valve its Cv, xT, opening and Cv needed ; for a pump its NPSH available. Nodes lists the nodes, their kind, pressure, temperature, flows, vapour fraction, density, Z, molar mass, viscosity and fluid.

The Nodes table.
Figure 38 The Nodes table.

11.2 The sheet : labels, colours, tables#

The labels of the Home page offer the gas mode's quantities : for the links name, length, nominal diameter, mass, standard and actual flow, velocity, Mach, pressure drop, outlet temperature, vapour fraction, holdup, flow pattern, ρv² ; for the nodes ID, name, elevation, pressure, temperature, stream flow, standard flow, vapour fraction, density, and Given (P / F). The colour rule colours by any of them. Add table places tables of pipes, compressors, pumps, valves, exchangers, pressure drops, separators, streams, nodes, the H&MB, the property probes or the Calculator on the sheet, each of the elements and quantities chosen.

11.3 The heat and material balance#

H&MB : F09's streams side by side.
Figure 39 H&MB : F09's streams side by side.

H&MB on the Reports page sets the streams of the last Run side by side : the conditions, the flows - mass, gas, liquids, molar, standard and actual - the properties, and the composition by mole or mass, of the whole stream, its gas or its liquids. Add nodes..., Add links... and Remove choose the columns ; Copy and Export to Excel take it out. A black oil's column gives its oil, gas and water at standard conditions.

11.4 Property probes#

Property probes on F05's sales gas : its hydrate temperature and its two dew points.
Figure 40 Property probes on F05's sales gas : its hydrate temperature and its two dew points.
Table 15 The properties a probe offers
GroupProperties
PhasesHydrate formation temperature ; hydrate margin ; water dew point ; hydrocarbon dew point ; bubble point pressure ; vapour fraction
FlowsWater cut ; gas-oil ratio ; gas-liquid ratio ; standard gas flow ; actual flow
The fluidDensity, Z, molar mass, viscosity, cp, cp/cv, speed of sound, Joule-Thomson coefficient
Gas quality (ISO 6976)Higher and lower heating values, Wobbe index (MJ/Sm³)
Oil qualityReid vapour pressure ; true vapour pressure at 37.8 °C

Add opens the selector : the nodes by kind, the property, Add probes. Each probe is a variable, Prop1, Prop2 ..., which the Calculator, Adjust and the Scenario Manager can use. Table on the flowsheet places them on the sheet.

12 Settings and sizing#

The Unit System page in the gas mode.
Figure 41 The Unit System page in the gas mode.

In the gas mode the Settings keep what a gas network needs. The Unit System has four rows of its own : Std gas flow (MSm³/d, Sm³/h, MMSCFD), Actual flow (m³/h, m³/s, ft³/h, ft³/min), Gas head (kJ/kg, m, ft) and Heat transfer (W/m²K, Btu/h·ft²·°F) ; the units of the liquid mode alone are greyed. The SI, US and Metric presets set them too. The colours of the Display page name the compressor and the separator.

Sizing offers Criteria sets for the gas mode : by phase - liquid, water, gas, multiphase - a maximum and minimum velocity, a velocity of the form k/ρ^n, a maximum drop, ρv² and Mach number ; NORSOK's and API RP 14E's sets built in, a set of your own copied from them. The phase of each pipe is read from its Run.

13 What a Run says#

The list of a Run's notes : F04, its expander.
Figure 42 The list of a Run's notes : F04, its expander.

A Run that solves says, in the Errors / Warnings / Information list beside the status bar, what it did that you should know. A Run that fails says why in its message.

Table 16 Some of the notes of a gas Run
It saysMeaning
... is choked : its flow is its critical oneThe gas reaches the speed of sound at the end of a pipe, a valve or an orifice
... cannot hold its setting : ... left fully openA valve that cannot reach what it is given
... lets the gas down : it works as an expanderA compressor whose ratio is below 1 : it gives power
... runs left of its surge line / beyond its stonewallA compressor on its curve outside its points
... takes in gas with its liquid ...A pump whose suction is below its liquid's bubble point
... cannot pass the liquid of ...A level valve or line that cannot take the separator's liquid at the pressures there
... meet : blended by their stock-tank volumesBlack oils of different figures that met, and how they were blended
... the temperatures crossTwo sides of one exchanger whose temperatures cross
... is mostly water, and here it is hot ...A fluid of water by Peng-Robinson or SRK where it boils : choose CPA or IAPWS-IF97
the network is over-specifiedTwo pressures given that the network cannot both hold
the gas network did not convergeNewton found no balance ; it stops early when it gains nothing for 20 steps. HMB only, a check of the specifications, or a split of the model, finds why