About this manual#
The gas mode of FlowMax solves networks of gas, of gas and liquid, and of water and steam, in steady state: the pressure and the temperature at every node, the flow and the phases in every link, the duty of every exchanger and the power of every machine. This manual teaches it through twenty examples - ten networks and ten facilities, each group from the smallest to the biggest: from a fuel gas system to a flare network of fifteen relief valves and a town's grid of 760 pipes, and from a boil-off gas compressor to an oil production facility and a whole LNG plant with its utilities.
The first, the fuel gas system, is built step by step. The others are opened and run as their project files stand, and read: the sheet after the Run, the streams, the equipment, what the Run says, and what to retain.
Most of them are worked out from compositions, by an equation of state. N09, an oil field of twelve wells, is worked out by black oil, each well an oil of its own ; F09 makes a fluid from its well fluid by its GOR and its water cut, and runs its wells both ways, by composition and by black oil.
The examples are illustrative. Their numbers are chosen for teaching and are typical of the industry; they come from no plant. Every number in the text, the tables and the figures is the program's own, read from the run that made the page.
The twenty examples#
| Example | What it is | Links |
|---|---|---|
| N01 | Fuel gas system | 25 |
| N02 | Subsea flowline and riser | 4 |
| N03 | CO2 injection wells | 10 |
| N04 | Compressor station and export line | 19 |
| N05 | City gate station | 21 |
| N06 | Plant air and nitrogen | 33 |
| N07 | Wells to a central processing facility | 33 |
| N08 | Flare network, three areas | 42 |
| N09 | Oil field gathering, black oil | 48 |
| N10 | City gas grid | 760 |
| F01 | LNG boil-off gas | 9 |
| F02 | Steam system of an LNG plant | 10 |
| F03 | NGL column, five feeds and side draws | 19 |
| F04 | NGL recovery, gas subcooled process (GSP) | 45 |
| F05 | Dew point plant | 22 |
| F06 | Gas processing train | 22 |
| F07 | Compression and cooling water | 26 |
| F08 | Water and steam loop | 32 |
| F09 | Oil production facility | 50 |
| F10 | LNG plant with its utilities | 105 |
Units#
The examples use the units of a metric oil and gas project: kg/h, barg for pressures, bar for pressure drops, °C, m, mm for diameters, kW, MSm³/d for standard gas flows and m³/h for actual flows. The page Unit System of the Settings changes them; the gas mode has its own rows there for the standard and the actual flow.
The project files#
Each example is a project file named after its chapter, N01 to N10 and F01 to F10. It opens with File > Open and runs as it is.
Their sheets are drawn with 90° lines (the tick in the ribbon's Sheet group): each line with square bends, out of a vessel's nozzle the way it points. Whatever feeds a network is an Inlet stream - given its flow, or, where the source is a header, a well or a supply held at a pressure, given its Pressure, its flow then the result. What leaves is an Outlet stream, given its pressure or its flow. Each sheet is shown whole, after its Run; a wide one on an A3 page of its own, across.
N01 A fuel gas system#
A plant burns part of its own gas: in its gas turbines, which drive generators and compressors, in its fired heaters, and in the pilots that keep its flare alight. The fuel gas system takes that gas from a high-pressure header and delivers it to each user at the pressure the user needs, clean, dry and warm enough. The pressure is let down in steps, and a gas let down cools - the Joule-Thomson effect - so the gas is heated before the first let-down; a knock-out drum after it catches any liquid.
This example builds such a system, small enough to set up in a quarter of an hour: one header, one filter, one heater, two pressure-control valves, a knock-out drum, and six users on flow control. It teaches the inlet stream given its pressure, the exchanger, the specifications of a valve, the separator, and how to read the temperature a let-down gives.

The fluid#
| Component | Mole % |
|---|---|
| Methane | 86.5 |
| Ethane | 6.0 |
| Propane | 2.5 |
| i-Butane | 0.5 |
| n-Butane | 0.7 |
| i-Pentane | 0.2 |
| n-Pentane | 0.2 |
| n-Hexane | 0.4 |
| n-Heptane | 0.2 |
| Nitrogen | 1.3 |
| CO2 | 1.5 |
A gas from a plant, mostly methane, with a little of the heavier hydrocarbons up to heptane. Those few tenths of a per cent of hexane and heptane decide its dew point: the temperature at which, at a given pressure, its first drop of liquid condenses. The method of properties is Peng-Robinson, the one FlowMax advises for natural gas.
- On the New project page choose Gas.
- Open the Fluid window from the ribbon, add the components and their mole fractions, keep Peng-Robinson, and press Confirm.

The network#
| Element | What it is | Data | What it does |
|---|---|---|---|
| HDR | Inlet stream, given its pressure | 70 barg, 30 °C | The plant's fuel gas header : it gives what the network takes |
| FLT | Pressure drop | 0.3 bar at 20 000 kg/h | The filter |
| HTR | Exchanger | 0.5 bar at 20 000 kg/h ; outlet 60 °C | The fuel gas heater |
| PCV-1 | Valve, Pressure set | Cv 30 ; 25 barg at V2 | The first let-down |
| KO | Separator, two phases | Its liquid by LV-1 | The knock-out drum |
| LV-1 | Valve | Cv 0.5 | Its level valve, to DRAIN at 1 barg |
| FCV-1, FCV-2 | Valves, Flow set | Cv 50 ; 9 000 kg/h each | The gas turbines GT-1 and GT-2, at 18 barg |
| PCV-2 | Valve, Pressure set | Cv 10 ; 6 barg at LPH | The second let-down |
| FCV-A, B, C | Valves, Flow set | Cv 12 ; 720 kg/h each | Three fired heaters, at 0.5 barg |
| FCV-P | Valve, Flow set | Cv 1.2 ; 72 kg/h | The flare pilots, at 0.5 barg |
| Pipes | Length | Inside diameter |
|---|---|---|
| P-1, P-2, P-3 : header to PCV-1 | 50, 10, 10 m | 154 mm (6 in) |
| P-4, P-5 : PCV-1 to the HP header HPH | 20, 30 m | 203 mm (8 in) |
| P-6, P-7 : the drum's liquid | 5, 30 m | 26.6 mm (1 in) |
| P-8, P-9 : to the turbines | 200, 220 m | 154 mm (6 in) |
| P-10 : to PCV-2 | 150 m | 102 mm (4 in) |
| P-11, P-12, P-13 : to the heaters | 120, 140, 160 m | 78 mm (3 in) |
| P-14 : to the pilots | 300 m | 26.6 mm (1 in) |
The header#
The header is an Inlet stream given its Pressure: a node that holds a pressure. Whatever the network asks of it, it gives; its flow is the result, what the users burn. The temperature it is given is that of the gas that comes in.
- Draw the pipes with the Pipe tool, as on the sheet.
- Press Inlet on the Equipment panel and click the first node : it becomes HDR. Open it, choose Given : Pressure, give 70 barg and 30 °C.

The filter and the heater#
A filter is a pressure drop: its drop at one flow is given, and FlowMax scales it with the square of the flow. The heater is the same, with a temperature to give the gas on its Heat Transfer tab; its duty is a result.
- Press PD and click between F1 and F2 : the filter. Give 20 000 kg/h and 0.3 bar.
- Press Exchanger and click between H1 and H2 : the heater. The same reference flow and 0.5 bar ; on Heat Transfer, the outlet temperature, 60 °C.


The valves#
A valve is given its Cv and a Specification. Pressure set holds a pressure at a node - its own outlet unless another is chosen - and works out the opening that does it. Flow set passes the flow given and works out its opening too. Rating leaves the opening as it is typed and works out the flow. The opening is the share of the Cv the valve needs: a sized valve runs between about 20 and 80 %.
- Press Valve and click between V1 and V2 : PCV-1. Cv 30, Pressure set, the node V2, 25 barg.
- The same for PCV-2 : Cv 10, 6 barg at LPH.
- The users' valves FCV-1, FCV-2, FCV-A, FCV-B, FCV-C, FCV-P : Flow set, with their flows.
- The users GT-1 ... PILOTS : Outlet streams at the pressure each burns at.


The knock-out drum#
A node becomes a separator with the Separ. button. Its window lists its outlets by the height of their far ends - the highest takes the gas, the lowest the liquid - and the valve that holds its level. The gas, the primary phase, leaves freely; the liquid leaves by its level valve, which passes what the flash at the drum condenses.

The Run and its results#
Run solves the network at once: the pressures, the flows, the temperatures, the phases. The users burn 20 232 kg/h, which the header gives. The filter takes 0.31 bar, the heater warms the gas from 30 to 60 °C with 447 kW. PCV-1 lets it down to 25 barg and it cools to 40.2 °C; the turbines receive it at 36.6 °C. PCV-2 lets it down again, to 29.9 °C, and the burners get it at 26.7 °C. No liquid forms anywhere: the drum stays dry and LV-1 is shut.
| Valve | Flow (kg/h) | Drop (bar) | Outlet (°C) | Opening (%) |
|---|---|---|---|---|
| PCV-1 | 20232 | 44.13 | 40.2 | 69.4 |
| PCV-2 | 2232 | 18.94 | 29.9 | 63.9 |
| FCV-1 | 9000 | 6.89 | 36.6 | 63.7 |
| FCV-2 | 9000 | 6.88 | 36.6 | 63.8 |
| FCV-A | 720 | 5.45 | 26.7 | 65.7 |
| FCV-B | 720 | 5.45 | 26.7 | 65.8 |
| FCV-C | 720 | 5.44 | 26.7 | 65.9 |
| FCV-P | 72 | 5.16 | 26.8 | 68.7 |
Each valve runs between 64 and 69 % open: sized right, with room to move. The gas cools by a few degrees in each user's valve too. The pipes are well below the velocities that would be noisy: 8.5 m/s in the HP header, 7.6 m/s to the heaters. The pressure the turbines' valves see is 24.89 barg, the heaters' 5.95 barg.


Variant : the heater off#
The heater keeps the gas warm through two let-downs. Take its outlet temperature away - on its Heat Transfer tab, no heat - and run again.
| Where | Heater on | Heater off |
|---|---|---|
| KO, after PCV-1 (°C) | 40.2 | 7.6 |
| Gas turbines (°C) | 36.6 | 3.2 |
| LP header, after PCV-2 (°C) | 29.9 | -5.3 |
| Burners of the heaters (°C) | 26.7 | -9.3 |
| Vapour fraction in KO | 1.0000 | 0.9940 |
| Liquid out of KO (kg/h) | 0 | 442 |
| LV-1 opening (%) | 0 | 26.8 |
Let down from 70 to 25 barg at 30 °C, the gas falls to 7.6 °C: below its dew point at that pressure. 442 kg/h of hexane, heptane and the like condense, and the drum catches them; LV-1 opens to 26.8 % to pass them. The gas that leaves the drum is at its dew point, and the burners receive it at -9.3 °C. A gas at its dew point condenses again on the first cold wall, and liquid in the fuel of a gas turbine damages it; below 0 °C any water would freeze or form hydrates. That is what the heater is for.

Variant : the turbines at peak load#
Each turbine now burns 11 000 kg/h. The header gives 24 232 kg/h; the heater needs 538 kW, PCV-1 opens to 83.6 % and the turbines' valves to 78.3 %, their inlet at 24.83 barg. PCV-1 still holds 25 barg with room to spare. Were a flow asked that a valve cannot pass even fully open, the Run would say so - "cannot hold its setting" - and leave it fully open: the network then shows what the valve can do.
What to retain#
- A node that holds a pressure - an Outlet stream - feeds the network as well as it drains it : its flow is a result.
- An exchanger is a pressure drop with a temperature to give ; its duty is a result.
- Pressure set, Flow set and Rating say what a valve is asked ; its opening is the result, and a sized valve runs between about 20 and 80 %.
- A gas let down cools. Read the temperatures after every let-down, against the dew point and against 0 °C.
- A separator's liquid leaves by its level valve, which passes what the flash condenses.
N02 A subsea flowline and its riser#
A gas condensate from a subsea manifold : 8 km on the seabed, 300 m below the sea, then a 320 m riser to the platform, the sea at 4 °C around it ; on the platform the choke into the separator. Beggs and Brill along the line gives the holdup and the flow pattern, and the liquid that gathers at the riser's foot.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| MF | Inlet | 44.52 | 70.00 | 6.000E4 | 46.12 | 0.9701 |
| SEP | Outlet | 30.00 | 5.174 | 6.000E4 | 46.12 | 0.8224 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| HV | 6.000E4 | 4.522 | 100.0 | 5.184 | 0.8224 |
What the Run says#
- Solved in 2.4 s.
What to retain#
- In a riser the hydrostatic head of the liquid dominates : the holdup matters more than the friction.
- A cold sea cools the fluid fast ; condensate drops out along the line.
- Read the flow pattern along the line : where it changes, the line may slug.
N03 CO2 injection wells#
Dense CO2 from the arrival header through 3 km to the well pad, then three wells, each its wellhead piping, its choke and a tubing 2 000 m down to the reservoir, warmed by the rock. The weight of the dense column adds to the pressure going down.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| ARR | Inlet | 98.59 | 12.00 | 3.420E5 | 0.0000 | |
| BH-1 | Outlet | 230.0 | 26.00 | 1.203E5 | 0.0000 | |
| BH-2 | Outlet | 235.0 | 26.16 | 1.141E5 | 0.0000 | |
| BH-3 | Outlet | 240.0 | 26.33 | 1.076E5 | 0.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| CK-1 | 1.203E5 | 13.31 | 100.0 | 11.30 | 0.0000 |
| CK-2 | 1.141E5 | 11.98 | 100.0 | 11.37 | 0.0000 |
| CK-3 | 1.076E5 | 10.65 | 100.0 | 11.43 | 0.0000 |
What the Run says#
- Solved in 9.7 s.
What to retain#
- Dense CO2 behaves like a liquid : the column down a well adds pressure.
- Its density changes strongly with temperature : the rock's warmth matters.
- The chokes share the CO2 between the wells, against their reservoir pressures.
N04 A compressor station and its export line#
A pipeline's gas arrives at 45 barg : the suction scrubber, two compressors in parallel on their curve, the aftercooler, an anti-surge valve back to the suction, and 40 km to the city gate held at 55 barg. Machines in parallel on one curve share the flow ; tripping one moves the other along its curve.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| SUC | Inlet | 25.00 | 25.00 | 2.527E5 | 290.2 | 1.0000 |
| GATE | Outlet | 18.00 | 20.91 | 2.527E5 | 290.2 | 1.0000 |
| DRAIN | Outlet | 5.000 | 25.00 | 0 | 0 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-1 | Curve | 24.77 | 32.21 | 1.288 | 1510 | 46.71 |
| K-2 | Curve | 24.77 | 32.21 | 1.288 | 1510 | 46.71 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| AC | 2.527E5 | 46.69 | 45.00 | -254.5 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| ASV | 0 | 7.020 | 0 | 0 | 1.0000 |
| LV-1 | 0 | 19.80 | 0.00 | 0 | 1.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| SCR | 2 phases | 24.80 | 24.91 | 2.527E5 | 0 |
What the Run says#
- Solved in 1.3 s.
What to retain#
- Compressors in parallel on the same curve share the flow equally ; their operating point is where the line meets the curve.
- An anti-surge valve recycles cooled gas to the suction : the machine sees more flow than the pipeline.
- Trip one machine and the other runs further out on its curve, at a lower head.
N05 A city gate station#
Natural gas from the transmission line at 60 barg in winter : two filters, the heater - the gas cools about half a degree a bar through the regulators - then two regulator runs, each a monitor and an active regulator, run B the standby, and 1 km to the city.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| HP | Inlet | 60.00 | 8.000 | 6.000E4 | 68.91 | 1.0000 |
| CITY | Outlet | 15.12 | 10.000 | 6.000E4 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E-1 | 6.000E4 | 7.905 | 30.00 | 960.4 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| PCV-MA | 6.000E4 | 1.689 | 100.00 | 29.31 | 1.0000 |
| PCV-AA | 6.000E4 | 41.77 | 29.13 | 10.000 | 1.0000 |
| PCV-MB | 0.078 | 21.74 | 0.00 | 20.61 | 1.0000 |
| PCV-AB | 0.078 | 21.74 | 0.00 | 9.991 | 1.0000 |
What the Run says#
- Solved in 13.4 s.
- PCV-MB is shut : the pressure it holds is above its setting.
- PCV-AB is shut : the pressure it holds is above its setting.
What to retain#
- A regulator holds the pressure after it ; the monitor stays wide open while the active one works.
- The heater upstream keeps the gas above its hydrate and dew point after the letdown.
- A standby run set lower stays shut while the duty run holds its pressure.
N06 Plant air and nitrogen#
Plant air and a nitrogen package on one site : the air compressed and dried, a membrane - a component splitter - taking nitrogen from it, and the two distributions to their users.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| AIR | Inlet | 0 | 30.00 | 4820 | 3.375 | 1.0000 |
| IA-1 | Outlet | 7.328 | 40.00 | 1500 | 1.0000 | |
| IA-2 | Outlet | 7.432 | 40.00 | 1000 | 1.0000 | |
| DRAIN-1 | Outlet | 0 | 25.00 | 0 | 0 | 1.0000 |
| DRAIN-2 | Outlet | 0 | 40.15 | 50.14 | 0.0001 | |
| PURGE | Outlet | 0 | 19.42 | 737.3 | 0.522 | 0.9675 |
| N2-1 | Outlet | 7.582 | 40.00 | 800.0 | 1.0000 | |
| PERMEATE | Outlet | 0 | 38.34 | 733.1 | 0.495 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-1 | Ratio | -7.628E-4 | 2.024 | 3.000 | 197.2 | 173.3 |
| K-2 | Ratio | 1.956 | 7.895 | 3.000 | 203.7 | 187.5 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E-1 | 4820 | 173.3 | 40.00 | -184.3 |
| E-2 | 4820 | 187.5 | 40.00 | -238.2 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-1 | 0 | 1.957 | 0.00 | 0 | 0.9812 |
| LV-2 | 50.14 | 7.826 | 1.04 | 40.15 | 0.0001 |
| PV-1 | 737.3 | 7.784 | 25.54 | 19.42 | 0.9673 |
| PV-2 | 733.1 | 7.768 | 25.11 | 38.34 | 1.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| KO-1 | 2 phases | 1.957 | 40.00 | 4820 | 0 |
| KO-2 | 2 phases | 7.826 | 40.00 | 4770 | 50.14 |
| DRY | Splitter | 7.823 | 40.00 | 4770 | 0 |
| MEM | Splitter | 7.797 | 40.00 | 1533 | 0 |
What the Run says#
- Solved in 3.2 s.
What to retain#
- A membrane is modelled as a splitter : each component's share to the top.
- Air and nitrogen are gases of one phase : the Run is quick, the pressures are what matter.
- Each user's flow is given ; the supply pressure is what the farthest needs.
N07 Wells to a central processing facility#
Six wells - three of gas condensate, three of light oil - each through its choke and its flowline to a manifold, the two manifolds by a 15 km trunkline to the central processing facility : the HP separator, its gas to the compression, its liquid let down to the LP separator, the oil pumped to export. Several fluids meet in one network ; the flowlines carry two phases.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| W-1 | Inlet | 140.0 | 80.00 | 1.478E4 | 0.338 | 0.9791 |
| W-2 | Inlet | 125.0 | 75.00 | 1.753E4 | 0.401 | 0.9541 |
| W-3 | Inlet | 110.0 | 70.00 | 1.905E4 | 0.435 | 0.9381 |
| W-4 | Inlet | 60.00 | 65.00 | 3.312E4 | 0.416 | 0.5788 |
| W-5 | Inlet | 52.00 | 62.00 | 3.106E4 | 0.390 | 0.5958 |
| W-6 | Inlet | 45.00 | 60.00 | 2.611E4 | 0.328 | 0.6122 |
| HP GAS | Outlet | 25.00 | 31.24 | 6.459E4 | 1.788 | 1.0000 |
| LP GAS | Outlet | 2.000 | 21.14 | 5533 | 0.105 | 1.0000 |
| OIL | Outlet | 15.00 | 23.53 | 7.153E4 | 0.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| CK-1 | 1.478E4 | 104.7 | 100.0 | 49.59 | 0.9404 |
| CK-2 | 1.753E4 | 87.52 | 100.0 | 48.49 | 0.9366 |
| CK-3 | 1.905E4 | 70.48 | 100.0 | 47.66 | 0.9334 |
| CK-4 | 3.312E4 | 23.33 | 100.0 | 59.98 | 0.6364 |
| CK-5 | 3.106E4 | 14.21 | 100.0 | 58.75 | 0.6313 |
| CK-6 | 2.611E4 | 7.547 | 100.0 | 58.15 | 0.6313 |
| LV-1 | 7.706E4 | 22.43 | 47.23 | 22.26 | 0.1900 |
| LV-2 | 7.153E4 | 19.25 | 45.95 | 23.52 | 0.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| HPS | 2 phases | 25.05 | 31.26 | 6.462E4 | 7.703E4 |
| LPS | 2 phases | 2.059 | 21.16 | 5533 | 7.153E4 |
| Name | Mass flow (kg/h) | Pressure rise (bar) | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|
| P-OIL | 7.153E4 | 31.71 | 22.56 |
What the Run says#
- Solved in 3.6 s.
What to retain#
- Each well its own fluid ; where streams meet, the fluid is their mixture by mass.
- Each well is an inlet given its wellhead pressure : its flow is what its choke and the trunkline let through.
- Two-phase lines : read the flow pattern and the holdup, not only the pressure drop.
- The separators' level valves pass their liquid ; the plant is solved at once, its mass balance closed.
N08 A flare network#
A general power failure : fifteen relief valves open at once, five in each of three process areas. Each discharges through its tail pipe - 6 in for the large ones, 4 in below 25 000 kg/h - into its area's sub-header, the three sub-headers into the main header, which grows from 20 to 30 in as the areas join it, 300 m to the knock-out drum, its liquid by a level valve to the drain, then the stack, 80 m up, and the tip. The flows and the temperatures are given at the relief valves ; the tip and the drain are at the atmosphere ; every pressure up the network - the back pressure at each relief valve above all - follows from the flow.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| RV-A1 | Inlet | 5.356 | 40.00 | 6.000E4 | 51.67 | 1.0000 |
| RV-A2 | Inlet | 3.390 | 130.0 | 2.500E4 | 21.53 | 1.0000 |
| RV-A3 | Inlet | 4.318 | 180.0 | 1.200E4 | 10.33 | 1.0000 |
| RV-A4 | Inlet | 4.403 | 25.00 | 4.000E4 | 34.45 | 1.0000 |
| RV-A5 | Inlet | 3.404 | 60.00 | 8000 | 6.889 | 1.0000 |
| RV-B1 | Inlet | 3.105 | 80.00 | 3.000E4 | 25.84 | 1.0000 |
| RV-B2 | Inlet | 4.211 | 35.00 | 4.500E4 | 38.75 | 1.0000 |
| RV-B3 | Inlet | 4.792 | 150.0 | 1.500E4 | 12.92 | 1.0000 |
| RV-B4 | Inlet | 2.528 | 45.00 | 5000 | 4.306 | 1.0000 |
| RV-B5 | Inlet | 6.588 | 90.00 | 2.000E4 | 17.22 | 1.0000 |
| RV-C1 | Inlet | 6.071 | 30.00 | 7.000E4 | 60.28 | 1.0000 |
| RV-C2 | Inlet | 3.085 | 120.0 | 1.000E4 | 8.612 | 1.0000 |
| RV-C3 | Inlet | 4.987 | 60.00 | 1.800E4 | 15.50 | 1.0000 |
| RV-C4 | Inlet | 2.682 | 200.0 | 6000 | 5.167 | 1.0000 |
| RV-C5 | Inlet | 3.900 | 40.00 | 3.500E4 | 30.14 | 1.0000 |
| TIP | Outlet | 0 | 59.90 | 3.990E5 | 343.6 | 1.0000 |
| DRAIN | Outlet | 0 | 25.00 | 0 | 0 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-1 | 0 | 0.373 | 0.00 | 0 | 1.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| KO | 2 phases | 0.373 | 60.50 | 3.990E5 | 0 |
What the Run says#
- Solved in 2.8 s.
What to retain#
- In a flare network the flows are given and the pressures found : the back pressure at each relief valve is the result that matters, against what its type of valve allows.
- Read the Mach number along the tail pipes and the header : a tail pipe near 1 is close to choking, and a choked pipe passes only its critical flow, said by the Run.
- The governing case sets the header : run the areas alone and together, and size for the worst.
- The knock-out drum and its level valve are part of the network : their liquid leaves by its own line.
N09 An oil field gathered, by black oil#
An oil field of twelve wells in three reservoirs, gathered to its central processing facility and worked out by black oil. Each well is a fluid of its own : its reservoir's oil - 32 API by Standing's correlations for reservoir A, 40 API by Vasquez-Beggs's for B, 27 API by its PVT table at 85 °C for C - with its own gas-oil ratio and water cut, from its last well test. The A and C wells are given their test rates ; the B wells their flowing wellhead pressures, their rates the results of their chokes and lines. Each well's choke and flowline of 6 in run to its cluster's manifold, three trunklines to the CPF - TL-C over a ridge 30 m high - and the inlet separator HPS, three phases, its gas held at 14 barg, its oil and its water each by its level valve.

Its oils#
Each fluid is a black oil with its own figures, in the Fluid window : Kind Black oil, then its oil's gravity, its gas's, its GOR, its water cut and its water's salinity, by correlations (A) or by its PVT table (B). Where lines of different oils meet, FlowMax blends them by their stock-tank volumes, and the Run says so.
| Fluid | Way | Oil (API) | Gas (air = 1) | GOR (Sm³/Sm³) | Water cut (%) | Salinity (ppm) |
|---|---|---|---|---|---|---|
| A-1 | A, Standing | 32.0 | 0.760 | 90.0 | 5.0 | 80 000 |
| A-2 | A, Standing | 32.0 | 0.760 | 110.0 | 20.0 | 80 000 |
| A-3 | A, Standing | 32.0 | 0.760 | 85.0 | 35.0 | 80 000 |
| A-4 | A, Standing | 32.0 | 0.760 | 130.0 | 10.0 | 80 000 |
| A-5 | A, Standing | 32.0 | 0.760 | 100.0 | 50.0 | 80 000 |
| B-1 | A, Vasquez-Beggs | 40.0 | 0.820 | 180.0 | 0.0 | 40 000 |
| B-2 | A, Vasquez-Beggs | 40.0 | 0.820 | 220.0 | 8.0 | 40 000 |
| B-3 | A, Vasquez-Beggs | 40.0 | 0.820 | 250.0 | 15.0 | 40 000 |
| B-4 | A, Vasquez-Beggs | 40.0 | 0.820 | 200.0 | 25.0 | 40 000 |
| C-1 | B, its table at 85 °C | 27.0 | 0.720 | 50.0 | 30.0 | 120 000 |
| C-2 | B, its table at 85 °C | 27.0 | 0.720 | 60.0 | 45.0 | 120 000 |
| C-3 | B, its table at 85 °C | 27.0 | 0.720 | 45.0 | 60.0 | 120 000 |
Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| A-1 | Inlet | 27.49 | 80.00 | 4.200E4 | 0.3131 | |
| A-2 | Inlet | 25.39 | 80.00 | 3.500E4 | 0.1828 | |
| A-3 | Inlet | 24.72 | 80.00 | 2.800E4 | 0.0814 | |
| A-4 | Inlet | 28.25 | 80.00 | 5.000E4 | 0.3177 | |
| A-5 | Inlet | 24.57 | 80.00 | 3.000E4 | 0.0571 | |
| B-1 | Inlet | 42.00 | 90.00 | 4.299E4 | 0.297 | 0.5425 |
| B-2 | Inlet | 38.00 | 90.00 | 3.621E4 | 0.4467 | |
| B-3 | Inlet | 45.00 | 90.00 | 5.396E4 | 0.3767 | |
| B-4 | Inlet | 36.00 | 90.00 | 3.951E4 | 0.2382 | |
| C-1 | Inlet | 19.46 | 70.00 | 2.500E4 | 0.0585 | |
| C-2 | Inlet | 20.08 | 70.00 | 3.000E4 | 0.0406 | |
| C-3 | Inlet | 19.31 | 70.00 | 2.000E4 | 0.0168 | |
| GAS | Outlet | 14.00 | 67.34 | 4.614E4 | 1.135 | 1.0000 |
| OIL | Outlet | 4.000 | 67.98 | 2.890E5 | 0.0440 | |
| PW | Outlet | 2.000 | 67.68 | 9.753E4 | 0.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| CK-A1 | 4.200E4 | 0.719 | 100.0 | 80.02 | 0.3147 |
| CK-A2 | 3.500E4 | 0.538 | 100.0 | 80.01 | 0.1833 |
| CK-A3 | 2.800E4 | 0.245 | 100.0 | 80.01 | 0.0815 |
| CK-A4 | 5.000E4 | 1.262 | 100.0 | 80.01 | 0.3196 |
| CK-A5 | 3.000E4 | 0.261 | 100.0 | 80.01 | 0.0572 |
| CK-B1 | 4.299E4 | 12.60 | 100.0 | 89.79 | 0.5700 |
| CK-B2 | 3.621E4 | 7.080 | 100.0 | 89.84 | 0.4567 |
| CK-B3 | 5.396E4 | 13.77 | 100.0 | 89.67 | 0.3915 |
| CK-B4 | 3.951E4 | 6.989 | 100.0 | 89.96 | 0.2439 |
| CK-C1 | 2.500E4 | 0.163 | 100.0 | 70.01 | 0.0586 |
| CK-C2 | 3.000E4 | 0.219 | 100.0 | 70.01 | 0.0406 |
| CK-C3 | 2.000E4 | 0.069 | 100.0 | 70.00 | 0.0168 |
| LV-1 | 2.890E5 | 9.299 | 61.39 | 67.94 | 0.0406 |
| LV-2 | 9.753E4 | 12.04 | 31.84 | 67.68 | 0.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| HPS | 3 phases | 14.16 | 67.40 | 4.616E4 | 3.865E5 |
What the Run says#
- Solved in 2.5 s.
- A-1, A-2, A-3 and 9 more meet : blended by their stock-tank volumes : the oil 34.7 API, the gas 0.796 ; their tables blended at 85.0 C.
What to retain#
- In a black-oil project each fluid is an oil of its own : its gravity, its gas's, its GOR and its water cut. Where lines meet, the oils are blended by their stock-tank volumes, and the Run says how.
- A well is given its rate, or its wellhead pressure : the node label Given (P / F) shows which on the sheet.
- A trunkline over a ridge carries its liquid uphill : read its profile and its holdup on its Profile tab.
- A PVT table (way B) holds at its own temperature ; correlations (way A) follow the temperature along the lines.
Each well its own oil#
The Fluid window, Fluids tab : each of the twelve wells is a fluid of its own, its Kind Black oil. B-2 takes its reservoir's oil - 40 API, its gas 0.82, by Vasquez-Beggs - and its own GOR, 220 Sm³/Sm³, and water cut, 8 %. A new well of the same reservoir starts as a Copy of one of them, its GOR and its water cut then typed. C-1 to C-3 take way B : their reservoir's PVT table, typed or read from a PVT file.

B-1 is given its flowing wellhead pressure : in its window, Given Pressure, 42 barg and its temperature. Its rate is the result - 42986 kg/h through its choke and its line. A and C wells are given their test rates instead, Given Flow, their wellhead pressures the results.

The node labels Name and Given (P / F) on the sheet : P where a stream is given its pressure, F where it is given its flow.

N10 A city gas grid of 760 pipes#
A looped distribution grid of 400 nodes and 760 pipes, fed at one corner with 72 000 kg/h of methane and held at its far corner : the size of a town's network. It shows that the gas mode solves a large looped network as quickly as a small one, and how to read it - the pressure falling across the grid, the flows sharing themselves between the loops.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| G0-0 | Inlet | 41.19 | 20.00 | 7.200E4 | 90.11 | 1.0000 |
| G19-19 | Outlet | 39.00 | 20.00 | 7.200E4 | 90.11 | 1.0000 |
What the Run says#
- Solved in 3.0 s.
What to retain#
- A looped network shares its flow between the loops : no pipe carries what a tree would make it carry.
- The run time grows with the network, not with the loops : 760 pipes solve in a few seconds.
- Colour the sheet by pressure to see the grid's drop at a glance ; a table of the sheet picks out the pipes that matter.
F01 LNG boil-off gas#
The boil-off of an LNG tank at -155 °C through an insulated line to the two-stage BOG compressor, each stage with its cooler, to the fuel gas header. Very cold gas warms in the line ; the tank's pressure follows from the compression.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| TANK | Inlet | 0.283 | -155.0 | 1.200E4 | 13.98 | 1.0000 |
| FUEL | Outlet | 8.000 | 35.00 | 1.200E4 | 13.98 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-1 | Ratio | 0.222 | 2.693 | 3.000 | 314.3 | -100.8 |
| K-2 | Ratio | 2.469 | 8.736 | 2.800 | 762.0 | 140.4 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E-1 | 1.200E4 | -100.8 | 35.00 | 897.7 |
| E-2 | 1.200E4 | 140.4 | 35.00 | -780.7 |
What the Run says#
- Solved in 1.3 s.
What to retain#
- A cold gas warms in its line even insulated : the compressor's suction is warmer than the tank.
- Two stages with a cooler between need less power than one.
- The tank's pressure is a result : the compressors set it.
F02 The steam system of an LNG plant#
The steam that heats the reboiler of the LNG plant's condensate stabiliser (F10), as a project of its own under IAPWS-IF97 : the boilers raising steam to the high-pressure header, the pressure-reducing station to the low-pressure header, the flow control valve of the reboiler, the reboiler condensing the steam, and the condensate back through its trap. The reboiler's duty is the one the plant's Run gives.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| BOILERS | Inlet | 40.00 | 400.0 | 8182 | 9.119 | 1.0000 |
| CONDENSATE RETURN | Outlet | 0.500 | 111.6 | 8182 | 0.0560 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| R-STB | 8182 | 371.5 | 140.8 | -5954 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| PRV-LP | 8182 | 35.47 | 11.21 | 371.9 | 1.0000 |
| FV-RB | 8182 | 0.444 | 85.88 | 371.5 | 1.0000 |
| TRAP | 8182 | 3.500 | 10.51 | 111.6 | 0.0560 |
What the Run says#
- Solved in 1.1 s.
What to retain#
- Water and steam : IAPWS-IF97, made for them ; a cubic method is not.
- A utility is its own project when its fluid is its own : the duty passes from one to the other.
- A trap passes liquid only : the condensate line after it carries what flashes at its lower pressure.
F03 An NGL column#
A distillation column of 30 stages separating an NGL : five feeds at their own stages, a liquid side draw and a vapour side draw on their lines, three side duties - two coolers and a heater - a total condenser and a reboiler. The column is a separator whose Separate-by is Column : its stages are solved by their own method, the bubble points stage by stage, inside the network's Run ; the bottoms leave by their level valve, the liquid draw by its flow valve.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| SLUG CATCHER | Inlet | 13.62 | 40.00 | 8000 | 0.0000 | |
| SCRUBBERS | Inlet | 13.65 | 30.00 | 5000 | 0.0000 | |
| LPG RECYCLE | Inlet | 13.69 | 35.00 | 4000 | 0.0000 | |
| STABILISER | Inlet | 13.73 | 55.00 | 3000 | 0.0000 | |
| DEETHANISER | Inlet | 13.79 | 70.00 | 6000 | 0.0000 | |
| C3 PRODUCT | Outlet | 13.50 | 36.05 | 5790 | 0.0025 | |
| C5+ PRODUCT | Outlet | 8.000 | 110.4 | 1.721E4 | 0.3637 | |
| SIDE LPG | Outlet | 8.000 | 40.69 | 2000 | 0.2692 | |
| SIDE VAPOUR | Outlet | 12.50 | 104.8 | 1000 | 0.334 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-101 | 1.721E4 | 5.366 | 32.04 | 110.4 | 0.2397 |
| FV-101 | 2000 | 5.339 | 30.65 | 40.69 | 0.1817 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| C-101 | Column | 13.51 | 46.34 | 0 | 2.600E4 |
What the Run says#
- Solved in 1.9 s.
What to retain#
- A column is a node of the network : what comes in by its feed lines is what its stages separate ; what goes out by its lines is what they give.
- Its two targets fix it : here the reflux ratio and the boil-up ratio ; a product rate or a component in a product are other choices.
- Read the profile on its Column tab : the temperature and the flows stage by stage, the condenser's and the reboiler's duty.
- A side draw takes from its stage what its rate asks ; a draw that asks more than the stage has is said.
F04 NGL recovery, the gas subcooled process (GSP)#
The gas subcooled process of NGL recovery. 100 000 kg/h of rich gas at 75 barg and 25 °C is chilled to -4 °C in E5, then to -30 °C in a three-sided exchanger against the cold residue gas and the column's side reboiler, into the cold separator SEP-1. Its gas is split : 52 000 kg/h through the turboexpander K1, from 70 to 26 barg and down to -70 °C, into the demethanizer at stage 3 ; 10 000 kg/h condensed and subcooled to -79 °C in E1 against the column's overhead and let down by Valve3 onto its top tray at -94 °C - the subcooled reflux that gives the process its name. The separator's liquid is let down by Valve2 to stage 15. The demethanizer SEP-2 is a column of 30 stages at 25 barg with its reboiler, its bottoms held to 1 % methane ; its side reboiler draws 20 000 kg/h of liquid at stage 20 through E7 and returns it to stage 21. The residue gas warms in E1 and the exchanger, is recompressed by K2 and K3 to 70 barg and cooled to 35 °C in E4 ; the NGL, 33 000 kg/h, leaves by its level valve at 20 barg.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| N8 | Outlet | 20.00 | 33.05 | 3.302E4 | 0.1121 | |
| N23 | Outlet | 70.00 | 34.82 | 6.698E4 | 80.57 | 1.0000 |
| N24 | Inlet | 75.08 | 25.00 | 1.000E5 | 96.48 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K1 | Pressure set | 70.00 | 25.72 | 0.376 | -702.5 | -70.45 |
| K2 | Pressure set | 21.19 | 31.08 | 1.445 | 1183 | 24.61 |
| K3 | Pressure set | 30.00 | 71.57 | 2.341 | 3318 | 108.2 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E1 | 10000 | -31.53 | -78.99 | -844.3 |
| E2 | 6.698E4 | -79.99 | -63.72 | 844.3 |
| E3 | 6.698E4 | -64.60 | -6.916 | 2590 |
| E4 | 6.698E4 | 108.1 | 35.00 | -3656 |
| E5 | 1.000E5 | 24.66 | -4.000 | -2917 |
| E6 | 1.000E5 | -4.310 | -30.00 | -3532 |
| E7 | 2.000E4 | -48.31 | -5.000 | 941.6 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| Valve1 | 3.302E4 | 4.861 | 50.15 | 33.05 | 0.1121 |
| Valve2 | 3.802E4 | 44.88 | 49.90 | -56.63 | 0.4637 |
| Valve3 | 10000 | 41.83 | 50.20 | -92.22 | 0.1936 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| SEP-1 | 2 phases | 72.16 | -30.24 | 6.198E4 | 3.802E4 |
| SEP-2 | Column | 25.00 | -61.94 | 6.187E4 | 5.813E4 |
What the Run says#
- Solved in 47.6 s.
- Recycle loops : 1, each worked out from its tears found by themselves - P21 into SEP-2.
- K1 lets the gas down : it works as an expander (ratio 0.376), it gives 702.5 kW - drawn as an expander.
- P19 has 0.01 bar (0.3 m of its liquid) to spare passing draw 1 of SEP-2 : a resistance to add on its line (a valve, an orifice) - else its level falls.
What to retain#
- A turboexpander cools the gas far more than a valve : it takes work from it - the Run says what it gives and draws it as an expander.
- The subcooled reflux : part of the cold gas condensed against the overhead and flashed onto the top tray washes the ethane back down ; the column needs no condenser.
- A side reboiler is a draw and a feed of the column joined through an exchanger : its liquid runs down to it by its own head. The column's Geometry puts the draw at its tray, 8.4 m up here ; at the node's elevation the Run would say the line cannot pass it.
- One exchanger of three sides : the feed cooled, the residue gas and the side reboiler's liquid warmed at once.
F05 A dew point plant#
A wet rich gas under CPA : the inlet separator and its free water, the glycol unit as a splitter, the gas-gas exchanger, the chiller, the low temperature separator and its NGL, the cold gas back to the sales line. Two probes at the sales gas give its water and hydrocarbon dew points.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| FEED | Inlet | 67.09 | 40.00 | 1.000E5 | 96.28 | 0.9836 |
| SALES | Outlet | 66.00 | 31.59 | 8.460E4 | 87.46 | 1.0000 |
| DRAIN | Outlet | 5.000 | 41.12 | 1418 | 0.0011 | |
| TEG WATER | Outlet | 2.000 | 41.33 | 113.9 | 0.0000 | |
| NGL | Outlet | 20.00 | -22.36 | 1.387E4 | 0.3352 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E-1H | 9.847E4 | 39.97 | 11.94 | -2433 |
| E-2 | 9.847E4 | 11.94 | -5.054 | -1734 |
| E-1C | 8.460E4 | -5.063 | 31.63 | 2433 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-1 | 1418 | 62.06 | 4.18 | 41.12 | 0.0011 |
| LV-2 | 113.9 | 65.04 | 0.82 | 41.33 | 0.0000 |
| LV-3 | 1.387E4 | 45.82 | 16.86 | -22.06 | 0.3319 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| IS | 2 phases | 67.06 | 39.98 | 9.858E4 | 1418 |
| TEG | Splitter | 67.04 | 39.98 | 9.858E4 | 0 |
| LTS | 2 phases | 66.33 | -5.056 | 8.460E4 | 1.387E4 |
What the Run says#
- Solved in 11.0 s.
What to retain#
- For water with hydrocarbons, CPA ; it puts the water where it belongs.
- Probes give the water and hydrocarbon dew points of a stream after each Run.
- Chill colder to bring the hydrocarbon dew point down ; the glycol unit takes the water first.
F06 A gas processing train#
A gas processing train in its main steps : separation, treating and recovery modelled by separators and component splitters, with the compression and the exchangers between them. Each splitter is given each component's share to its top ; the rest goes to its bottom.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MMSCFD) | Vapour fraction |
|---|---|---|---|---|---|---|
| FEED | Inlet | 46.67 | 45.00 | 1.500E5 | 144.6 | 0.9622 |
| ACID | Outlet | 1.500 | -7.790 | 1.829E4 | 8.671 | 1.0000 |
| EXPORT | Outlet | 90.00 | 31.54 | 1.265E5 | 130.2 | 1.0000 |
| TEG WATER | Outlet | 2.000 | 45.92 | 291.8 | 0.0000 | |
| COND | Outlet | 10.00 | 25.00 | 0 | 0 | 0.9629 |
| PW | Outlet | 2.000 | 45.70 | 4913 | 0.0013 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-1 | Ratio | 46.39 | 93.80 | 2.000 | 4271 | 107.4 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| AC | 1.265E5 | 107.4 | 45.00 | -6058 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-3 | 1.829E4 | 44.60 | 15.30 | -7.790 | 1.0000 |
| LV-4 | 291.8 | 44.42 | 2.54 | 45.92 | 0.0000 |
| LV-1 | 0 | 36.54 | 0.00 | 0 | 0.9592 |
| LV-2 | 4913 | 44.52 | 8.56 | 45.70 | 0.0013 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| IS | 3 phases | 46.54 | 45.00 | 1.451E5 | 4913 |
| AGR | Splitter | 46.47 | 45.00 | 1.451E5 | 0 |
| TEG | Splitter | 46.42 | 45.00 | 1.268E5 | 0 |
What the Run says#
- Solved in 1.9 s.
What to retain#
- A component splitter models a unit by its recoveries - an amine unit, a dehydration, a column - without its internals.
- The plant's mass balance closes across every unit.
- Read the H&MB at every stream : what each unit takes out.
F07 Compression and its cooling water#
A lean gas compressed in two stages, its intercooler and aftercooler exchanger pairs with the cooling water - the same fluid package for both - and the cooling water circuit itself : the tower basin, the pump, the supply and return headers at their heights, up to the tower's distributor.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| SUCTION | Inlet | 19.28 | 35.00 | 8.000E4 | 2.505 | 1.0000 |
| EXPORT | Outlet | 95.00 | 52.55 | 8.000E4 | 2.505 | 1.0000 |
| DRAIN | Outlet | 2.000 | 25.00 | 0 | 0 | 1.0000 |
| BASIN | Inlet | 0 | 30.00 | 9.818E5 | 0.0000 | |
| TOWER | Outlet | 0 | 36.10 | 9.818E5 | 0.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-1 | Ratio | 19.25 | 43.56 | 2.200 | 3295 | 106.7 |
| K-2 | Ratio | 42.99 | 95.80 | 2.200 | 3334 | 123.1 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| E-1H | 8.000E4 | 106.7 | 48.83 | -3157 |
| E-2H | 8.000E4 | 123.0 | 52.57 | -4267 |
| E-1C | 4.924E5 | 30.02 | 35.17 | 3157 |
| E-2C | 4.894E5 | 30.02 | 37.02 | 4267 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-1 | 0 | 41.01 | 0.00 | 0 | 1.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| KO | 2 phases | 43.01 | 48.82 | 8.000E4 | 0 |
| Name | Mass flow (kg/h) | Pressure rise (bar) | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|
| P-CW | 9.818E5 | 2.406 | 30.02 |
What the Run says#
- Solved in 2.1 s.
What to retain#
- An exchanger pair links two circuits : the gas's heat goes to the cooling water.
- The cooling water circuit has its own heights : the pump lifts it to the tower.
- One fluid package for gas and water is fine where the water stays cool.
F08 A water and steam loop#
A whole steam and water loop under IAPWS-IF97 : the deaerator, two feed pumps on their curves (one standby), the boiler raising superheated steam at 40 barg and 400 °C, a turbine valve, two letdown stations with a desuperheater to the medium and low pressure headers, an insulated main that loses heat and its drip pot, a heater condensing its steam, and the condensate back through its traps to the condensate tank. It teaches the method of properties for water, the letdown of superheated steam, mixing water into steam, and condensation where heat is lost.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| DA | Inlet | 1.500 | 127.0 | 2.702E4 | 0.0000 | |
| TURB | Outlet | 30.00 | 386.0 | 1.200E4 | 0.378 | 1.0000 |
| MP-2 | Outlet | 8.000 | 243.4 | 4000 | 0.126 | 1.0000 |
| LP-1 | Outlet | 3.000 | 234.4 | 3000 | 0.094 | 1.0000 |
| LP-2 | Outlet | 3.375 | 147.1 | 2000 | 1.0000 | |
| DRAIN | Outlet | 0 | 99.93 | 23.44 | 0.0889 | |
| CT | Outlet | 0.200 | 105.1 | 6000 | 0.0142 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| BLR | 2.552E4 | 127.8 | 400.0 | 1.884E4 |
| E-M1 | 6000 | 233.4 | 112.6 | -4100 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| FCV-T | 1.200E4 | 18.29 | 20.09 | 386.0 | 1.0000 |
| PRV-1 | 1.352E4 | 38.03 | 50.91 | 369.5 | 1.0000 |
| FCV-M1 | 6000 | 7.464 | 45.62 | 233.4 | 1.0000 |
| FCV-M2 | 4000 | 1.596 | 72.74 | 243.4 | 1.0000 |
| FCV-DSH | 1500 | 39.58 | 9.48 | 128.5 | 0.0000 |
| PRV-2 | 5023 | 6.386 | 58.06 | 235.3 | 1.0000 |
| FCV-L1 | 3000 | 0.467 | 81.03 | 234.4 | 1.0000 |
| TR-1 | 23.44 | 3.383 | 1.54 | 99.93 | 0.0889 |
| TR-2 | 6000 | 2.028 | 100.0 | 105.1 | 0.0142 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| DP-1 | 2 phases | 3.383 | 147.1 | 2000 | 23.44 |
| Name | Mass flow (kg/h) | Pressure rise (bar) | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|
| FP-1 | 2.702E4 | 47.02 | 127.8 |
What the Run says#
- Solved in 6.5 s.
- S2 : only links set aside (blocked or ignored) reach it - left out, no flow.
- D2 : only links set aside (blocked or ignored) reach it - left out, no flow.
What to retain#
- For water and steam alone, IAPWS-IF97 ; a cubic method makes steam at 1 bar and 100 °C a liquid.
- A letdown station cools superheated steam little ; a desuperheater's water brings it towards saturation.
- An insulated line still loses heat : the steam arrives wetter, and a drip pot takes its condensate.
- A gas line beyond a drip pot needs its own flow : a pressure there draws whatever the network gives.
F09 An oil production facility#
Three wells - 90 000, 70 000 and 40 000 kg/h of well fluid at 80 °C, oil, gas and water - each on its choke and its flowline over the ground to the manifold ; the three-phase HP separator, its water to the produced water, its oil heated and let down to the MP and LP separators ; the oil pumped 2 km to export ; the LP and MP gas recompressed in two stages into the HP gas ; and that gas compressed again for export and sent 20 km. The wells' pressures follow from their chokes, the flowlines and the plant ; the separators' pressures from the gas export and the compressors' ratios.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| W-1 | Inlet | 39.04 | 80.00 | 9.000E4 | 0.3419 | |
| W-2 | Inlet | 36.34 | 80.00 | 7.000E4 | 0.3494 | |
| W-3 | Inlet | 31.25 | 80.00 | 4.000E4 | 0.3641 | |
| GAS EXPORT | Outlet | 75.00 | 45.00 | 4.521E4 | 1.062 | 0.9376 |
| PW | Outlet | 0.500 | 79.62 | 2.285E4 | 0.0000 | |
| DRAIN | Outlet | 0.500 | 1.913 | 7528 | 0.3867 | |
| OIL | Outlet | 15.00 | 79.39 | 1.244E5 | 0.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| K-EX | Ratio | 24.97 | 76.93 | 3.000 | 2199 | 164.7 |
| K-3 | Ratio | 1.149 | 6.337 | 3.400 | 155.0 | 129.4 |
| K-2 | Ratio | 6.224 | 25.04 | 3.600 | 376.4 | 132.1 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| AC-EX | 4.521E4 | 164.7 | 45.00 | -4486 |
| H-1 | 1.375E5 | 75.30 | 85.00 | 1008 |
| AC-3 | 5883 | 129.4 | 40.00 | -669.8 |
| AC-2 | 1.037E4 | 132.1 | 40.00 | -1022 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| CH-1 | 9.000E4 | 4.725 | 100.0 | 78.92 | 0.3558 |
| CH-2 | 7.000E4 | 3.061 | 100.0 | 79.26 | 0.3585 |
| CH-3 | 4.000E4 | 1.161 | 100.0 | 79.67 | 0.3677 |
| LV-1 | 1.375E5 | 17.95 | 31.75 | 75.30 | 0.1220 |
| LV-4 | 2.285E4 | 24.49 | 18.34 | 79.62 | 0.0000 |
| LV-2 | 1.303E5 | 4.183 | 61.76 | 81.15 | 0.0629 |
| LV-5 | 2762 | 5.287 | 17.68 | 43.28 | 0.1317 |
| LV-6 | 4766 | 24.05 | 15.55 | -6.587 | 0.4033 |
| LV-3 | 1.244E5 | 2.014 | 83.52 | 79.34 | 0.0000 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| HP | 3 phases | 25.13 | 79.15 | 3.961E4 | 1.604E5 |
| MP | 2 phases | 6.253 | 84.63 | 7247 | 1.303E5 |
| LP | 2 phases | 1.150 | 78.42 | 5883 | 1.244E5 |
| S2 | 2 phases | 6.227 | 57.34 | 1.037E4 | 2762 |
| S1 | 2 phases | 25.00 | 40.00 | 5602 | 4766 |
| Name | Mass flow (kg/h) | Pressure rise (bar) | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|
| P-OIL | 1.244E5 | 16.56 | 79.26 |
What the Run says#
- Solved in 5.5 s.
What to retain#
- A whole facility is one network : the wells, the flowlines, the separation and the compression are solved at once, and the wellhead pressures are results.
- Flowlines carry two phases over the ground : their pressure drop is the elevation and the holdup as much as the friction.
- Each separator holds its level by its valve ; three phases, its oil and its water by two.
- The export gas is rich : at its pressure and the cooler's temperature it may carry liquid - read its vapour fraction.
Late in its life : a fluid by its GOR and its water cut#
As a field ages its wells make more water and, below their bubble point in the reservoir, more gas. The well fluid of F09 has a GOR of 270 Sm³/Sm³ and a water cut of 11.7 %, read at 15 °C and 1.01325 bar. W-3 is now tested at a GOR of 410 and 40 % water. In the Fluid window, Fluids tab, GOR and water... makes that fluid from the well fluid : its gas taken as many times as the GOR asks for its oil, its water as the water cut asks, flashed again until it reads back what was asked.

The new fluid, Well fluid, late life, reads back a GOR of 410.0 and 40.0 % water. Given to W-3 - its stream's fluid - the plant is run again ; W-3 still makes 40000 kg/h, but more of it is water and gas :
| As it is | W-3 late in life | Difference | |
|---|---|---|---|
| W-1, pressure (barg) | 39.0 | 39.1 | 0.1 % |
| W-2, pressure (barg) | 36.3 | 36.4 | 0.1 % |
| W-3, pressure (barg) | 31.3 | 30.9 | -1.3 % |
| HP, pressure (barg) | 25.1 | 25.2 | 0.1 % |
| MP, pressure (barg) | 6.3 | 6.2 | -0.1 % |
| LP, pressure (barg) | 1.1 | 1.1 | -0.6 % |
| Gas export (kg/h) | 45212.8 | 46756.0 | 3.4 % |
| Oil export (kg/h) | 124407.6 | 114061.7 | -8.3 % |
| Produced water (kg/h) | 22851.3 | 32498.4 | 42.2 % |
| K-EX, power (kW) | 2199.0 | 2263.7 | 2.9 % |
| K-2, power (kW) | 376.4 | 326.2 | -13.3 % |
| K-3, power (kW) | 155.0 | 141.3 | -8.8 % |
The water to the produced-water line rises by 9647 kg/h and the oil to export falls by 10346 kg/h ; the export compressor takes 65 kW more for the gas.
Its wells by black oil#
Black oil is the usual model for wells and flowlines. F09's wells, chokes and flowlines into its HP separator are built again here and run twice : with the well fluid's composition, then with the well fluid made a black oil from that composition - the Fluid window, Kind Black oil, way C, its tables at 80 °C. Way C reads it as an oil of 73.3 API, its gas 0.917, a GOR of 267 Sm³/Sm³ and 11.5 % water.
| Composition | Black oil | Difference | |
|---|---|---|---|
| W-1, pressure (barg) | 38.99 | 39.17 | 0.5 % |
| W-2, pressure (barg) | 36.28 | 36.42 | 0.4 % |
| W-3, pressure (barg) | 31.19 | 31.25 | 0.2 % |
| FL-1, pressure drop (bar) | 8.37 | 8.44 | 0.8 % |
| FL-1, liquid holdup | 0.23 | 0.23 | -0.6 % |
| FL-3, liquid holdup | 0.21 | 0.21 | -0.4 % |
| HP, temperature (°C) | 79.15 | 79.78 | 0.8 % |
| HP gas (kg/h) | 39654.72 | 40321.24 | 1.7 % |
| HP oil (kg/h) | 137495.77 | 136541.51 | -0.7 % |
| HP water (kg/h) | 22849.51 | 23137.25 | 1.3 % |
The wellhead pressures agree within 0.5 %, the flowlines' drops and holdups within 0.8 % : for wells and their lines black oil does well, and it solves in 1.6 s for the composition's 1.6 s. The separator's split differs more - its gas by 2 % : the black oil's tables are those of 80 °C and its gas is of one composition whatever the pressure, where the composition flashes each component at the separator's own conditions.
The plant itself stays a project of compositions. Run as a black oil, its heater, its three stages of separation and its compression ask what tables made at one temperature cannot give : this oil is light - its stock-tank oil near 70 API - and it changes across each stage. Black oil suits the oils of N09 ; for a light oil through a plant, the composition.
F10 An LNG plant with its utilities#
A whole plant, 300 t/h of well fluid : the inlet facility and the condensate stabiliser, the acid gas removal and the dehydration, the NGL recovery by a turboexpander and its demethanizer, the LPG fractionation (deethanizer, depropanizer, debutanizer), then the LNG train - the propane precooler, the main cryogenic exchanger, the end flash drum and the tank. Beside it, its utilities as networks of their own fluids : the cooling water from the tower basin through its pump to three coolers and back, and the propane refrigeration circuit - its compressor, its condenser on the cooling water, its two letdowns to the chiller and the precooler. Five exchangers are the two sides of one across the networks. It was built and solved by parts first, each ended by an outlet at the pressure the next part takes, and the utilities alone with the process's duties given - then all together. The steam of the stabiliser's reboiler is a project of its own under IAPWS-IF97, F02.

Its streams#
Each inlet and outlet stream as the Run leaves it. An inlet is given its flow or its pressure, an outlet its pressure or its flow ; what is not given is the result. The node label Given (P / F) shows on the sheet which each one is.
| Name | Kind | Pressure (barg) | Temperature (°C) | Stream flow (kg/h) | Std gas flow (MSm³/d) | Vapour fraction |
|---|---|---|---|---|---|---|
| FEED | Inlet | 70.56 | 50.00 | 3.000E5 | 7.058 | 0.8703 |
| FUEL GAS | Outlet | 8.000 | 139.8 | 1.100E4 | 0.222 | 1.0000 |
| CONDENSATE | Outlet | 3.000 | 40.00 | 3.965E4 | 0.0000 | |
| PRODUCED WATER | Outlet | 2.000 | 51.31 | 1.421E4 | 0.0000 | |
| ACID GAS | Outlet | 1.500 | -43.44 | 2.290E4 | 0.303 | 1.0000 |
| DH WATER | Outlet | 2.000 | 51.30 | 343.3 | 0.0000 | |
| ETHANE | Outlet | 20.00 | -64.24 | 9802 | 0.0000 | |
| PROPANE | Outlet | 14.00 | -63.90 | 1.802E4 | 0.0000 | |
| BUTANE | Outlet | 5.000 | -63.35 | 1.294E4 | 0.0000 | |
| GASOLINE | Outlet | 2.000 | -63.16 | 1.603E4 | 0.0000 | |
| LP FUEL | Outlet | 1.000 | -153.8 | 6921 | 0.222 | 0.9989 |
| LNG TANK | Outlet | 0.150 | -160.4 | 1.482E5 | 0.0525 | |
| BASIN | Inlet | 0 | 30.00 | 7.345E6 | 0.0000 | |
| TOWER | Outlet | 0 | 34.34 | 7.345E6 | 0.0000 | |
| C3 SUCTION | Inlet | 0.100 | -38.00 | 2.475E5 | 3.185 | 1.0000 |
| C3 RETURN A | Outlet | 0.100 | -35.58 | 9.459E4 | 1.217 | 1.0000 |
| C3 RETURN B | Outlet | 0.100 | -35.57 | 1.529E5 | 1.967 | 1.0000 |
Its equipment#
The machines, exchangers, valves and separators, read from the same Run - as a table of the sheet shows them (Add table, the gas mode's kinds).
| Name | Specification | Inlet pressure (barg) | Outlet pressure (barg) | Pressure ratio | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|---|---|
| X-1 | Ratio | 69.36 | 30.66 | 0.450 | -1668 | -70.30 |
| K-RC | Ratio | 30.46 | 68.23 | 2.200 | 7277 | 126.8 |
| K-C3 | Pressure set | 0.094 | 14.60 | 14.107 | 1.114E4 | 78.96 |
| Name | Mass flow (kg/h) | Inlet temperature (°C) | Outlet temperature (°C) | Duty (kW) |
|---|---|---|---|---|
| H-STB | 5.064E4 | 33.48 | 140.0 | 5954 |
| E-COND | 3.965E4 | 123.8 | 40.00 | -2770 |
| E-GGH | 2.119E5 | 49.91 | -11.30 | -1.206E4 |
| E-C3H | 2.119E5 | -11.30 | -35.00 | -5912 |
| E-GGC | 1.551E5 | -64.82 | 48.84 | 1.206E4 |
| AC-RC | 1.551E5 | 126.8 | 40.00 | -9887 |
| E-PRE | 1.551E5 | 40.00 | -35.00 | -9555 |
| E-MCHE | 1.551E5 | -35.00 | -150.0 | -2.486E4 |
| AC-RCC | 3.395E6 | 30.04 | 32.41 | 9887 |
| E-CONDC | 5.537E5 | 30.04 | 34.08 | 2770 |
| C3-CONDC | 3.396E6 | 30.04 | 36.29 | 2.637E4 |
| C3-COND | 2.475E5 | 78.95 | 40.00 | -2.637E4 |
| E-C3C | 9.459E4 | -39.64 | -35.58 | 5912 |
| E-PREC | 1.529E5 | -39.02 | -35.56 | 9555 |
| Name | Mass flow (kg/h) | Pressure drop (bar) | Opening (%) | Outlet temperature (°C) | Vapour fraction |
|---|---|---|---|---|---|
| LV-SC1 | 5.064E4 | 61.61 | 2.52 | 33.53 | 0.3750 |
| LV-STB | 3.965E4 | 4.436 | 9.88 | 124.3 | 0.1803 |
| LV-SC2 | 1.421E4 | 68.27 | 1.01 | 51.31 | 0.0000 |
| LV-AGR | 2.290E4 | 68.55 | 3.33 | -43.01 | 1.0000 |
| LV-DH | 343.3 | 68.27 | 0.24 | 51.30 | 0.0000 |
| LV-CS | 6.543E4 | 38.61 | 6.11 | -53.98 | 0.3497 |
| LV-DM | 5.680E4 | 10.61 | 8.56 | -64.25 | 0.0000 |
| LV-DE | 4.699E4 | 5.834 | 14.05 | -63.91 | 0.0000 |
| LV-DP | 2.898E4 | 8.993 | 9.08 | -63.36 | 0.0000 |
| LV-DB | 1.603E4 | 2.859 | 13.11 | -63.17 | 0.0000 |
| JT | 1.551E5 | 65.83 | 100.0 | -152.6 | 0.0370 |
| LV-LNG | 1.482E5 | 1.229 | 15.91 | -159.9 | 0.0491 |
| JT-C3A | 9.459E4 | 14.25 | 10.81 | -39.61 | 0.4802 |
| JT-C3B | 1.529E5 | 14.21 | 17.50 | -38.94 | 0.4775 |
| Name | Type | Pressure (barg) | Temperature (°C) | Gas through (kg/h) | Liquids through (kg/h) |
|---|---|---|---|---|---|
| SC | 3 phases | 70.29 | 49.92 | 2.351E5 | 6.485E4 |
| STB | Splitter | 8.096 | 139.9 | 3.865E4 | 1.199E4 |
| AGR | Splitter | 70.28 | 49.92 | 2.351E5 | 5.594 |
| DH | Splitter | 70.27 | 49.91 | 2.114E5 | 837.8 |
| CS | 2 phases | 69.36 | -35.00 | 1.465E5 | 6.543E4 |
| DM | Splitter | 30.65 | -64.81 | 1.362E5 | 7.566E4 |
| DE | Splitter | 20.00 | -64.24 | 0 | 5.680E4 |
| DP | Splitter | 14.07 | -63.90 | 0 | 4.699E4 |
| DB | Splitter | 5.035 | -63.35 | 0 | 2.898E4 |
| EFD | 2 phases | 1.009 | -153.7 | 6921 | 1.482E5 |
| Name | Mass flow (kg/h) | Pressure rise (bar) | Power (kW) | Outlet temperature (°C) |
|---|---|---|---|---|
| P-CW | 7.345E6 | 3.735 | 30.04 |
What the Run says#
- Solved in 23.9 s.
- X-1 lets the gas down : it works as an expander (ratio 0.450), it gives 1667.9 kW - drawn as an expander.
What to retain#
- Build a plant by parts : solve each alone, its end an outlet at the pressure the next part takes ; then join them.
- A utility is a network of its own fluid ; an exchanger pair carries the heat across, and each network keeps its own balance.
- Size a letdown and its rundown for the flash : the liquid that leaves a drum at its bubble point becomes mostly vapour by volume after the valve.
- A pure refrigerant boils at one temperature : give a saturated stream a few hundredths of a degree outside it.