1 Introduction#
FlowMax's Gas & Multiphase mode calculates networks of gas, of gas and liquid together, and of water and steam, in steady state: the pressure and the temperature at every node, the flow, the phases and the velocity in every link, the duty of every exchanger and the power of every machine. A fluid is a composition worked out by an equation of state, or a black oil worked out from its field figures.
This guide is a reference. It goes through the mode window by window and says what each field means and what each command does. It works no example: the Gas Training Manual does that, with twenty complete networks and facilities and their project files. Drawing a model - the sheet, the pipes, the nodes, the labels - is the same in every mode and is in the Steady State User Guide.
| Subject | What FlowMax offers |
|---|---|
| Fluids | Compositions from a library of 27 components and hypothetical ones, by Peng-Robinson, SRK, CPA, GERG-2008, Span-Wagner (CO2) or IAPWS-IF97 (water and steam) ; several fluids a project ; black oils by correlations, PVT tables or a composition |
| Streams | Inlets and outlets, each given its flow or its pressure ; a temperature, a superheat or a quality |
| Pipes | Gas, two phases by Beggs and Brill or no slip, isothermal, adiabatic or exchanging heat with the ground or the sea ; a profile of the ground ; connectors without loss |
| Equipment | Valves held at a flow, a pressure or a drop ; compressors and expanders on a ratio, a power or their curve ; pumps ; pressure drops, orifices ; exchangers, one side or two |
| Separation | Separators of two or three phases with their level valves or pumps and carryover ; splitters by component ; distillation columns of stages |
| Results | Tables of links and nodes, tables on the sheet, the heat and material balance, property probes (hydrate, dew points, heating values ...), the colour rule |
2 Installation and licence#
2.1 System requirements#
| Item | Requirement |
|---|---|
| Operating system | Windows 10 or Windows 11, 64-bit |
| Processor | Dual core, 1.8 GHz or faster |
| Memory | 4 GB; 8 GB recommended |
| Disk | 1 GB free |
| Screen | 1280 x 768 or larger |
| Internet | Needed to activate the licence, unless an offline file is used |
2.2 Installing#
- Start the Flowmax Setup application.
- Read the information of the first page and press Next if you agree.
- Choose whether a shortcut is put on the desktop.
- Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.
2.3 Activating the licence#
The first time FlowMax starts it shows the licence window.
- Activate License asks for the licence key that came with the purchase.
- Without internet, Offline license file writes a request to send to support, and Activate License reads the file that comes back.
FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.
What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.
2.4 Help and examples#
The File menu holds them, for the mode the project is in:
- Help File opens the user guide of the mode, Training Manual its training manual: from the folder docs beside the program, or, when they are not installed, from the tutorials page of processtool.net.
- Show Example opens the example projects of the mode, in the folder examples beside the program. The start window lists them all under Examples.
- About Flowmax gives the version and the licence.
The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.
3 The gas mode#
3.1 A new gas project#
File > New opens the start window. Its two cards choose the mode of the project: Liquid - water, oil, fire water, in steady state and transient - or Gas / multiphase. The gas card opens an empty sheet in the gas mode with methane as its fluid, the flows in kg/h and the pressures in barg; the Fluid window and the Settings change them. A project keeps its mode: a gas project opens as one.

3.2 The window in the gas mode#

| Command | What it does |
|---|---|
| Run | Solves the network : chapter 11 for what it gives, chapter 13 for what it says |
| Scenario Case | The case the sheet shows, when there are several |
| Calculation | Hydraulics + HMB : every pressure loss. HMB only : the pipes taken without their pressure loss - the flows, the separators, the temperatures and the balance as ever, in a second ; the pressures are not those of a full Run. The status bar then says Solved - HMB only |
| Fluid | The Fluid window : chapter 4 |
| Units, Setting | The units and the Settings : chapter 12 |
| Links, Nodes, Graphs | The tables of the links and of the nodes, the charts : chapter 11 |
| Grid, Energy lines, Setting colors | The sheet's grid ; the dashed line between the two sides of an exchanger ; the colour rule |
The Equipment panel holds what a gas network is made of: pipes and their bends, inlet and outlet streams, valves, pumps, compressors, pressure drops and exchangers, the separator, tees and reducers, text, notes and tables. The Transient page is not in the gas mode.

3.3 The order of work#
- Fluid : the components and the package, then each fluid of the project (chapter 4).
- Draw the network. Make the ends Inlet and Outlet streams and give each its flow or its pressure (chapter 5).
- Give each pipe its size and how it exchanges heat (chapter 6), each valve and machine its specification (chapters 7 and 8).
- Make the separators, their outlets and their level valves (chapter 10).
- Run. Read the sheet, the tables, the H&MB and the probes (chapter 11), and what the Run says (chapter 13).
Before a run A missing input is listed beside the status bar, as in the liquid mode. A gas network needs at least one node at a given pressure : an outlet, or an inlet given its pressure.
4 Fluids#
Fluid on the Home page opens the Fluid window. It has two tabs: Components and package, one list of components and one equation of state for the whole project, and Fluids, the fluids of the project made from them.
4.1 Components and package#

| Package | For |
|---|---|
| Peng-Robinson | Natural gas, condensate, oil : the usual choice |
| SRK | The same, the older equation |
| CPA (water, glycols) | Fluids with water, methanol, MEG or TEG : their association is in it |
| Span-Wagner (pure CO2) | CO2 alone, its reference equation ; other fluids of the project by Peng-Robinson |
| IAPWS-IF97 (water and steam) | Water alone, its industrial standard ; other fluids by CPA |
| GERG-2008 (gas, one phase) | Natural gases of one phase, the reference for custody transfer ; where a fluid condenses, Peng-Robinson is the better choice and the Run says so |
- Library : search, then Add to the list (or a double-click). Nitrogen, CO2, H2S, water, hydrogen, oxygen, argon, helium, methane to n-decane, benzene, toluene, methanol, MEG, TEG, ethylene, propylene.
- Hypothetical : a component of your own - its name, molar mass and density at 15 °C, and what you know of its boiling point, critical point and acentric factor ; what is left blank is estimated. Its row can be typed in the table ; a double-click on its name opens all its data.
- Remove takes a component out of every fluid.
4.2 Fluids#

| Field | Meaning |
|---|---|
| Fluids, New, Copy, Rename, Remove | The fluids of the project. A project keeps one at least. A stream names the fluid it brings |
| Composition of ..., by Mole / Mass | Its fractions, mole or mass. Click a cell and type ; a column copied from a sheet pastes with Ctrl+V on its first cell |
| Normalize, Total | Brings the fractions to a total of 1 |
| Fluid model (at the top) | Composition : every fluid of the project a composition. Black oil : every fluid a black oil (section 4.4) |
| At 15 °C, 1.01325 bar | Its molar mass, the density of its gas and its phases at standard conditions, worked out as it is typed |
| GOR and water... | A new fluid made from this one at the GOR and the water asked (section 4.3) |
Confirm checks every fluid - fractions that add up to 1, a black oil's figures - and offers IAPWS-IF97 or CPA when a fluid mostly of water is given to Peng-Robinson or SRK. A stream whose fluid was renamed follows it; one whose fluid was removed takes the first.
4.3 GOR and water : a fluid made from another#
As a field ages its wells make more water and more gas. GOR and water... makes a new fluid from a fluid of the project at the gas-oil ratio and the water asked: the fluid is flashed at 15 °C and 1.01325 bar, its gas taken as many times as the GOR asks for its oil, its water as the water cut (or the WOR) asks, and flashed again until it reads back what was asked. The fluid must have an oil at standard conditions, and water among its components when water is asked.

| Field | Meaning |
|---|---|
| From the fluid | The fluid it is made from ; its GOR and water cut at standard conditions shown under it |
| GOR | Sm³ of gas a Sm³ of oil, at standard conditions |
| Water cut, WOR | The water, % of the liquid by volume, or Sm³ of water a Sm³ of oil |
| Name | The new fluid's name, made from the figures until it is typed |
| Make the fluid | Adds it to the list, chosen ; Confirm the Fluid window to keep it |
4.4 Black oil#
A black oil is a fluid of three pseudo-components - the stock-tank oil, its gas, its water - whose properties come from the field's figures instead of an equation of state: the gas in solution and the bubble point, the oil's volume factor and viscosity, the gas's Z and viscosity, the water's density and viscosity. A project is all compositions or all black oils : Fluid model, at the top of the window. In a black-oil project each fluid has its own figures - in an oil field each well its oil, its GOR and its water cut - and its Kind : Oil, its gas and water, or Gas alone, a fuel gas or a lift gas.

| Field | Meaning |
|---|---|
| Oil gravity | API |
| Gas specific gravity | Air = 1 |
| Gas-oil ratio, GOR | Sm³/Sm³ : all its gas at standard conditions over its stock-tank oil |
| Water cut | % of the liquid by volume at standard conditions |
| Water salinity | ppm by mass ; 0 : fresh water |
| A : Correlations | Standing, Vasquez-Beggs or Glaso for the gas in solution, the bubble point and the volume factor ; the viscosity by Beggs-Robinson |
| B : its PVT table | A row a pressure : bara, the gas in solution Rs (Sm³/Sm³), Bo, the oil's viscosity (cP), Bg (rm³/Sm³), the gas's viscosity (cP), to the bubble point ; At its temperature. Read a PVT file... reads PVTO, PVTG or PVDG, PVTW, DENSITY and RTEMP, METRIC or FIELD |
| C : from a composition | Its own composition, typed by Composition... on the components of the first tab (Components : for C), At a temperature, Make its tables : the whole fluid's gas and oil at each pressure to its bubble point, over its stock-tank oil ; its GOR and water cut with them |
| Gas alone | Its gravity alone : A by Hall-Yarborough's Z and Lee-Gonzalez-Eakin's viscosity, or B its table of Bg and viscosity against pressure |



Changing the fluid model#
- Composition to Black oil : the window asks a temperature ; each fluid is made a black oil from its own composition at it (way C), a gas a gas alone of its gravity, water a black oil all water. Each keeps the composition it was made from.
- Black oil to Composition : a fluid made from a composition gets it back ; one typed by its figures or its table has none, and the window names it, to be typed. Its black oil stays in the window until it is closed : back to Black oil, it is there.
- Where lines of different black oils meet they are blended by their stock-tank volumes : the oil's gravity by its volume, the gas's by its standard volume, the salinity by the water's salt, the GOR and the water cut by the volumes. Correlations that differ : those of the larger oil. A table among them : every oil brought to tables at the tables' temperature and the tables blended. The Run says, as information, which fluids met and how.
- Above its bubble point the oil follows Vasquez-Beggs's compressibility and viscosity. Its gas's Z is Hall-Yarborough's on Sutton's pseudo-critical point ; its water is IAPWS's, its salt by McCain's ratios.
- Columns, splitters and composition probes are not for black oils : a black-oil project has no components to separate.
- Its limits. A table holds at its own temperature ; correlations follow the temperature. A light oil heated, cooled and let down through several stages is better worked out by its composition : the training manual's F09 shows both. A table of way C can show an oil volume factor below 1 at its lowest pressures : at the tables' temperature the lightest part of the stock-tank oil, propane to hexane, is still a gas and is counted with the gas - right by mass, as its composition has it.
5 Streams#
The ends of a network are streams: Inlet and Outlet on the Equipment panel, a tag pointing the way the gas goes. An inlet brings a fluid into the network, an outlet takes it out. Each is given its flow or its pressure ; what is not given is the result. A double-click opens its window ; on a node that is neither, the window shows its name, elevation and results : a junction.

| Field | Meaning |
|---|---|
| Given : Flow, Pressure | What is given ; the other is the result |
| Mass flow, Molar flow, Standard volume | An inlet's flow : kg/h (or the project's unit), kmol/h, or Sm³/h at 15 °C and 1 atm (23.645 m³/kmol) |
| Pressure | Its pressure, in the project's unit |
| Temperature, Superheat, Quality | An inlet's temperature ; or, for a fluid of one component (water, CO2), its superheat in K above its saturation at its own pressure, or its quality, % of vapour by mass |
| Fluid | The fluid it brings ; Fluids... opens the Fluid window |
| An outlet's flow | A mass flow leaving |
| Results | After a Run : the pressure or the flow not given, its vapour fraction, the fluids of an outlet's mix |



The node label Given (P / F) shows on the sheet which each stream is given : P its pressure, F its flow. Choose it in the node label lists of the Home page, as Name or Pressure.

6 Pipes#
The pipe window of the gas mode has the liquid mode's rows - name, length, schedule, size, material, roughness, fittings, status - and four of its own : the route, the temperature along the pipe, the two-phase flow and the connector.

| Field | Meaning |
|---|---|
| Route : Length, Profile | Its length typed, or its profile of distances and elevations on the Profile tab |
| Isothermal | The temperature stays as it comes in |
| Adiabatic | No heat exchanged : the gas cools as it expands (Joule-Thomson) |
| Heat to the surroundings | The heat it gives to the surroundings at the Ambient temperature, through U, overall on its inside area |
| Two-phase flow : Model | Beggs & Brill : the liquid holdup and the flow pattern, by the pipe's inclination ; Homogeneous (no slip) : gas and liquid as one fluid |
| Segments | The pipe is marched in this many segments (4 to 200) |
| Eq. length | Its fittings as a length of pipe ; a K factor as well, both count |
| No pressure loss | A connector : its two ends at one pressure, drawn dashed ; its length, bore and fittings left out |

The Profile tab takes distances and elevations, its two ends those of its nodes ; Show draws the elevation, the pressure, the temperature or the liquid holdup along it, and the table under it gives each at the end of each segment.

The ? beside U opens the U window : six typical cases worked out for this pipe's size - bare in air or in sea water, concrete-coated, polypropylene-coated, buried, insulated - and an estimate from its layers, from the steel out, and what surrounds it : air, water or the ground. Use writes the value into the pipe.
7 Valves#
A valve's Specification box says what holds it ; its opening is then the result. In a Run of the liquid mode's steady state the same box is used.

| Field | Meaning |
|---|---|
| Flow set | A flow, through itself or another link ; Pick... chooses the link |
| Pressure set | A pressure at a node : its downstream, its upstream or another anywhere in the network ; Pick... chooses the node |
| Drop set | The pressure drop across it |
| Rating | Its opening, % : its flow is the result |
| Cv, Kv ; Valve type | Its capacity, and its characteristic : linear, equal percentage, quick opening or a curve of its own |
| xT | The drop ratio at which a gas chokes through it (IEC 60534) ; 0.72 when not given |
| No reverse flow | A check : it shuts against a flow the other way |



A valve chosen in a separator's Level control is that separator's level valve : its title says so, its specification is frozen, its flow is the separator's liquid and its opening the result.
8 Compressors, expanders and pumps#
8.1 Compressors and expanders#
A compressor is drawn with its own symbol from the Equipment panel. Its window :

| Field | Meaning |
|---|---|
| Flow set | Its own flow : the ratio it needs is the result |
| Pressure set | A pressure at a node - its suction, its discharge or another : the ratio it needs is the result |
| Rating, by Pressure ratio | Its ratio, outlet over inlet, absolute. Below 1 it is an expander, which gives power |
| Rating, by Power | The power it takes |
| Rating, by Curve | Its curve at rated speed - actual inlet flow, head, efficiency - and its speed, % of rated ; other speeds by the fan laws. Outside its first and last points the Run says : surge, stonewall |
| Efficiency | Polytropic or Isentropic, % ; on its curve, the curve's |
| Results | Its power (an expander's : the power it gives) and its outlet temperature |


8.2 Pumps#

- Flow set : its flow ; the head it needs is the result, its curve not used.
- Pressure set : a pressure at a node - its discharge or another.
- Head set : its head, or the pressure it adds ; the flow is the result.
- Rating : on its curve at its relative speed. In the gas mode the curve's flow is the actual flow at its suction.
- Its NPSH available is a result, in the Links table : the margin of its suction over its liquid's bubble point. A pump that takes in gas with its liquid is said by the Run.
9 Pressure drops, orifices and exchangers#

| Field | Meaning |
|---|---|
| Calculate K | From a reference flow and its pressure drop : DP = K Flow^n |
| Specify K | K and n typed |
| Fixed PD | One pressure drop whatever the flow |
| PQ Curve | Its drop against its flow |
| Orifice | On a flow element : its bore, the pipe at its inlet ; ISO 5167-2 - the pressure taps (flange, corner, D and D/2), β, its discharge coefficient and expansibility, its pressure loss, and whether it is choked or outside the standard |
| Required flow (optional) | A flow the element is to pass, for the check of the Run |
9.1 An exchanger#
An exchanger is a pressure drop with a Heat Transfer tab : No heat transfer, Fixed duty (positive heats the fluid, negative cools it) or Outlet temperature.

The two sides of one exchanger : in the gas mode a fourth choice, From another exchanger, joins two exchangers of the network as the hot and the cold side of one. Its specification is one of Duty, Hot outlet, Cold outlet, UA or Approach ; the results give the duty, the LMTD and the smallest end difference, and the Run says when the temperatures cross. Merged draws the two as one circle where their lines cross ; Swap the sides exchanges them.


10 Separators, splitters and columns#
A node becomes a separator with the Separator of the Equipment panel. Its window :

| Field | Meaning |
|---|---|
| Phases | Two : gas and liquid. Three : gas, oil and water |
| Separate by | Phases : a flash ; Components - a splitter (section 10.1) ; Stages : a column (section 10.2) |
| Outlets | Which line takes the gas, the liquid (the oil) and the water ; None : it leaves the network here. Primary : the phase that leaves freely, its flow what is left ; the others are held. Given by the height of their far ends until chosen |
| Level control | The valve - or the pump - that holds each liquid's level : it passes that liquid, its opening (or its rise) the result |
| Carryover | % of a phase that leaves with another : liquid in the gas, gas in the liquid, water in the oil, oil in the water |
| Results | Its pressure, temperature and each phase out ; a level valve's opening, a pump's rise, what a gas line has to spare, the head a liquid line needs |
| Symbol | By its phases, vertical, horizontal, knock-out drum, horizontal with a water boot |
| Not a separator | Makes it a node again |

10.1 A splitter : separated by components#
In the place of an amine unit, a dryer, a membrane : the % of each component that leaves by the top - and the middle, with three - by moles, the bottom the rest ; the outlets at the inlet's temperature or at their own ; its duty the heat its outlets take. A black oil has no components to split.

10.2 A column of stages#
Stages : a column makes the separator a distillation column, solved stage by stage by its own method inside the network's Run, the phases of each stage by the project's equation of state. Its window gains two tabs.

| Field | Meaning |
|---|---|
| Type | Distillation : a condenser and a reboiler ; Stripper : a reboiler ; Absorber : neither |
| Stages, Condenser | The number of stages, the condenser the first and the reboiler the last ; a Total condenser gives the top liquid, a Partial one the top vapour |
| Feeds | Up to six : the line and the stage of each |
| Targets | Two for a distillation, one for a stripper, none for an absorber : reflux ratio, boil-up ratio, top or bottom rate, a component in the top or the bottom (mol %), a component's recovery, the bottom's RVP. Without a reflux ratio among them FlowMax finds it |
| Pressure drop | None, total or a stage's ; the top at the node's pressure |
| Products and results | The top and bottom lines ; the duties of the condenser and the reboiler, the top and bottom temperatures, the reflux and boil-up ratios ; Stage profile... |


Its method The column is solved by bubble points stage by stage. A column of wide-boiling feed with a methane-rich top may not converge ; the Run then refuses it and says why, and its separator by components is the fall-back.
11 Results#
11.1 The tables of the links and the nodes#

Links on the Home page lists the links by kind - Pipe, Pump, Compressor, Valve, Pressure drop, Exchanger - with their inputs and the Run's results : for a pipe its pressures, mass, standard and actual flows, velocity, Mach number, ρv², its pressure drop split into friction and static, its temperatures, vapour fraction, holdup, flow pattern and heat lost ; for a valve its Cv, xT, opening and Cv needed ; for a pump its NPSH available. Nodes lists the nodes, their kind, pressure, temperature, flows, vapour fraction, density, Z, molar mass, viscosity and fluid.

11.2 The sheet : labels, colours, tables#
The labels of the Home page offer the gas mode's quantities : for the links name, length, nominal diameter, mass, standard and actual flow, velocity, Mach, pressure drop, outlet temperature, vapour fraction, holdup, flow pattern, ρv² ; for the nodes ID, name, elevation, pressure, temperature, stream flow, standard flow, vapour fraction, density, and Given (P / F). The colour rule colours by any of them. Add table places tables of pipes, compressors, pumps, valves, exchangers, pressure drops, separators, streams, nodes, the H&MB, the property probes or the Calculator on the sheet, each of the elements and quantities chosen.
11.3 The heat and material balance#

H&MB on the Reports page sets the streams of the last Run side by side : the conditions, the flows - mass, gas, liquids, molar, standard and actual - the properties, and the composition by mole or mass, of the whole stream, its gas or its liquids. Add nodes..., Add links... and Remove choose the columns ; Copy and Export to Excel take it out. A black oil's column gives its oil, gas and water at standard conditions.
11.4 Property probes#

| Group | Properties |
|---|---|
| Phases | Hydrate formation temperature ; hydrate margin ; water dew point ; hydrocarbon dew point ; bubble point pressure ; vapour fraction |
| Flows | Water cut ; gas-oil ratio ; gas-liquid ratio ; standard gas flow ; actual flow |
| The fluid | Density, Z, molar mass, viscosity, cp, cp/cv, speed of sound, Joule-Thomson coefficient |
| Gas quality (ISO 6976) | Higher and lower heating values, Wobbe index (MJ/Sm³) |
| Oil quality | Reid vapour pressure ; true vapour pressure at 37.8 °C |
Add opens the selector : the nodes by kind, the property, Add probes. Each probe is a variable, Prop1, Prop2 ..., which the Calculator, Adjust and the Scenario Manager can use. Table on the flowsheet places them on the sheet.
12 Settings and sizing#

In the gas mode the Settings keep what a gas network needs. The Unit System has four rows of its own : Std gas flow (MSm³/d, Sm³/h, MMSCFD), Actual flow (m³/h, m³/s, ft³/h, ft³/min), Gas head (kJ/kg, m, ft) and Heat transfer (W/m²K, Btu/h·ft²·°F) ; the units of the liquid mode alone are greyed. The SI, US and Metric presets set them too. The colours of the Display page name the compressor and the separator.
Sizing offers Criteria sets for the gas mode : by phase - liquid, water, gas, multiphase - a maximum and minimum velocity, a velocity of the form k/ρ^n, a maximum drop, ρv² and Mach number ; NORSOK's and API RP 14E's sets built in, a set of your own copied from them. The phase of each pipe is read from its Run.
13 What a Run says#

A Run that solves says, in the Errors / Warnings / Information list beside the status bar, what it did that you should know. A Run that fails says why in its message.
| It says | Meaning |
|---|---|
| ... is choked : its flow is its critical one | The gas reaches the speed of sound at the end of a pipe, a valve or an orifice |
| ... cannot hold its setting : ... left fully open | A valve that cannot reach what it is given |
| ... lets the gas down : it works as an expander | A compressor whose ratio is below 1 : it gives power |
| ... runs left of its surge line / beyond its stonewall | A compressor on its curve outside its points |
| ... takes in gas with its liquid ... | A pump whose suction is below its liquid's bubble point |
| ... cannot pass the liquid of ... | A level valve or line that cannot take the separator's liquid at the pressures there |
| ... meet : blended by their stock-tank volumes | Black oils of different figures that met, and how they were blended |
| ... the temperatures cross | Two sides of one exchanger whose temperatures cross |
| ... is mostly water, and here it is hot ... | A fluid of water by Peng-Robinson or SRK where it boils : choose CPA or IAPWS-IF97 |
| the network is over-specified | Two pressures given that the network cannot both hold |
| the gas network did not converge | Newton found no balance ; it stops early when it gains nothing for 20 steps. HMB only, a check of the specifications, or a split of the model, finds why |