Skip to the text
Flowmax · Liquid

Quick Start

Liquid · October 2026

This is the shortest way from an empty sheet to a result. It has no example in it: it says what is pressed, in what order, and what the program answers. The training manual of the mode works through complete systems and explains every window; come back to this page for the order of things.

1 The window#

The FlowMax window. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.
Figure 1 The FlowMax window. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.

A model is links joined at nodes. A link carries flow: a pipe, a pump, a valve, a fixed loss (PD), a tank, a nozzle. A node is where links meet and where a pressure is reported.

2 A steady state in seven steps#

  1. Units and fluid. On the Home page press Units and choose the unit of each quantity, then Fluid: Constant properties, a fluid from the library at one temperature or its density, viscosity and vapour pressure typed; or Variable properties, the fluid of the library at the temperature of each pipe - the temperature then given where the fluid comes in, and changed by exchangers.
  2. Draw. Press a square of the Equipment strip. A pipe, a pump, a valve or a fixed loss takes two clicks on the sheet, its start and its end; click on an existing node to join it. A tank takes the node it stands on. A new pipe comes as 4 inch of schedule 40 (the reduced list), the default of the Settings. Press Scrolling, the hand on the strip at the left of the sheet, to stop drawing.
  3. Fill in each element. Double-click it. A pipe needs its length, its size (a schedule and a nominal diameter, or the bore typed), its roughness and its fittings. A pump needs its curve: points under Enter data, or coefficients. A valve needs its Cv and its opening. A tank needs its elevation, its level and the pressure over the liquid. A fixed loss drawn as an exchanger has a Heat Transfer tab: a fixed duty, or an outlet temperature.
  4. Give the edges. Double-click each node at an edge of the network. Choose Pressure and type it, or choose Flow and type it, with Sink ticked for a flow that leaves the network. Give every node its elevation, and, with Variable properties, the temperature of what comes in. At least one node, or a tank, must fix a pressure.
  5. Read the status bar. While it says Missing inputs, click it: the list names what is not yet given, element by element. When it says Ready to run, press Run.
  6. Read the results. The two Links and the two Nodes selectors above the sheet choose what is written beside every link and node. Select an element to see all of it in the panel at the right. The Links and Nodes tables of the Home page list every element. If the status says warnings or errors, click it and read the list before using a number.
  7. Keep it. Save writes the project file. The Reports page makes a PDF Report, a Datasheet of the pumps, the control valves and the orifices, an Excel workbook and a Screenshot of the sheet. Project information holds the project's name, reference, revision and company, and the logo, that they carry.
Table 1 The tools of the Tools page
ToolWhat it does
ScenarioRuns the model for a list of cases and tabulates chosen results; a case can then be shown on the sheet from the Scenario Case selector of the Home page
AdjustGoal seek: varies one input until one result reaches a target
CalculatorNamed formulas in the results of the model, recalculated by every run
Pipe SizingChooses pipe sizes to meet the limits of a criteria set: velocity, friction loss, ρv²
Nozzle LayoutLays spray nozzles out on a tank and inserts them with their pipework
DatabaseThe libraries of pipe schedules, fittings, fluids and nozzles

Graphs, on the Home page, draws a pump against its system, or any result along a path of links.

Base scenario Scenario, Adjust and Sizing change the model and work on the base case. If the Scenario Case selector shows a case, set it back to Base Scenario first.

3 Before a result is used#

Next: the Steady-State Training Manual, nine examples, each with its project file.