This is the shortest way from an empty sheet to a result. It has no example in it: it says what is pressed, in what order, and what the program answers. The training manual of the mode works through complete systems and explains every window; come back to this page for the order of things.
1 The window#

- The ribbon has the pages Home, Tools, Transient and Reports. File, at its left, holds New, Open, Save and Save As. New starts with the choice of the mode, Liquid or Gas, and opens the sheet.
- The Equipment strip holds everything that is placed on the sheet. Rest the mouse on a square to see its name. The surge protection - relief valve, air valve, accumulator, surge tank - and the controllers are greyed until the Transient mode is on.
- The panel at the right has two pages: Properties, the inputs and results of the element that is selected, and Elements, every element of the model with a box to find one by name.
- The status bar says where the model stands: Missing inputs, Ready to run, Solved, or Solved with warnings or errors. Click it for the list.
A model is links joined at nodes. A link carries flow: a pipe, a pump, a valve, a fixed loss (PD), a tank, a nozzle. A node is where links meet and where a pressure is reported.
2 A steady state in seven steps#
- Units and fluid. On the Home page press Units and choose the unit of each quantity, then Fluid: Constant properties, a fluid from the library at one temperature or its density, viscosity and vapour pressure typed; or Variable properties, the fluid of the library at the temperature of each pipe - the temperature then given where the fluid comes in, and changed by exchangers.
- Draw. Press a square of the Equipment strip. A pipe, a pump, a valve or a fixed loss takes two clicks on the sheet, its start and its end; click on an existing node to join it. A tank takes the node it stands on. A new pipe comes as 4 inch of schedule 40 (the reduced list), the default of the Settings. Press Scrolling, the hand on the strip at the left of the sheet, to stop drawing.
- Fill in each element. Double-click it. A pipe needs its length, its size (a schedule and a nominal diameter, or the bore typed), its roughness and its fittings. A pump needs its curve: points under Enter data, or coefficients. A valve needs its Cv and its opening. A tank needs its elevation, its level and the pressure over the liquid. A fixed loss drawn as an exchanger has a Heat Transfer tab: a fixed duty, or an outlet temperature.
- Give the edges. Double-click each node at an edge of the network. Choose Pressure and type it, or choose Flow and type it, with Sink ticked for a flow that leaves the network. Give every node its elevation, and, with Variable properties, the temperature of what comes in. At least one node, or a tank, must fix a pressure.
- Read the status bar. While it says Missing inputs, click it: the list names what is not yet given, element by element. When it says Ready to run, press Run.
- Read the results. The two Links and the two Nodes selectors above the sheet choose what is written beside every link and node. Select an element to see all of it in the panel at the right. The Links and Nodes tables of the Home page list every element. If the status says warnings or errors, click it and read the list before using a number.
- Keep it. Save writes the project file. The Reports page makes a PDF Report, a Datasheet of the pumps, the control valves and the orifices, an Excel workbook and a Screenshot of the sheet. Project information holds the project's name, reference, revision and company, and the logo, that they carry.
| Tool | What it does |
|---|---|
| Scenario | Runs the model for a list of cases and tabulates chosen results; a case can then be shown on the sheet from the Scenario Case selector of the Home page |
| Adjust | Goal seek: varies one input until one result reaches a target |
| Calculator | Named formulas in the results of the model, recalculated by every run |
| Pipe Sizing | Chooses pipe sizes to meet the limits of a criteria set: velocity, friction loss, ρv² |
| Nozzle Layout | Lays spray nozzles out on a tank and inserts them with their pipework |
| Database | The libraries of pipe schedules, fittings, fluids and nozzles |
Graphs, on the Home page, draws a pump against its system, or any result along a path of links.
Base scenario Scenario, Adjust and Sizing change the model and work on the base case. If the Scenario Case selector shows a case, set it back to Base Scenario first.
3 Before a result is used#
- The run says Solved with no error in its list. Every edge of the network is a pressure or a flow, and one of them is a pressure.
- A pump's NPSH available is above its NPSH required, with a margin; the warnings say where it is not.
- A control valve that ends fully open or nearly shut is not controlling: read its opening.
- With Variable properties, the temperatures are within the fluid's table: a note says when one is not.
Next: the Steady-State Training Manual, nine examples, each with its project file.