1 Introduction#
FlowMax has three modes: Liquid, Transient and Gas & Multiphase. This guide is about the Liquid mode in steady state. FlowMax calculates the flow, the pressure and, when asked, the temperature in a network of pipes that carries a liquid. The network is drawn on a sheet as links joined at nodes: pipes, pumps, valves, tanks, fixed losses and spray nozzles. In steady state the program finds the flows and pressures that balance. The same model can then be run in the Transient mode to follow a surge; that mode has a guide of its own, the Transient User Guide.
This guide is a reference. It goes through the window, the drawing of a model, the settings of a project, every piece of equipment, the results and the tables, every tool, the files and the reports, and the messages a run can give. For each window it says what every field means and what every command does. It works no example: the Steady-State Training Manual does that, with nine complete cases and their project files.
The pictures are the windows of the program itself. A red numbered circle on some of them marks a field the training manual speaks of; here it can be passed over.

| Subject | What FlowMax offers |
|---|---|
| Networks | Branched and looped networks of any shape, with several sources and several pumps; up to 4 999 links in one model, 40 with a Liquid Lite licence |
| Pressure drop | Darcy-Weisbach with the roughness of the pipe, or Hazen-Williams with its C factor in the form of NFPA 13 and EN 12845, with the velocity pressure of NFPA 13 and 15 if wanted; fittings from a library or as a K factor; an orifice plate by ISO 5167-2 |
| Temperature | A liquid of variable properties: the temperature of every node and link, from the supplies, the mixing of the flows and the exchangers; the density, the viscosity and the vapour pressure follow it |
| Equipment | Pumps on their curve or given a flow, a pressure or a head; valves at an opening or given a flow, a pressure or a drop; non-return valves, tanks, heat exchangers and other fixed losses, flow meters and orifice plates, spray nozzles |
| Fire water | Spray nozzles with their K factor and required flow; a tool that lays nozzles out on a tank or a roof and inserts them with their pipework |
| Studies | Scenarios, goal seek (Adjust), formulas in the results (Calculator), pipe sizing against criteria sets, graphs along a path, pump against system |
| Output | Results on the sheet, in tables and in graphs; a PDF report; an Excel workbook with a summary, an equipment list and a line list; datasheets of the pumps, the control valves and the orifices, in Excel and PDF |
| Exchange | EPANET files opened as FlowMax projects |
1.1 How the guide is written#
- A command or a field is written in bold, as the window writes it.
- A window is shown as the program draws it, filled with the values of an example; the values do not matter here.
- Units are those of the project. Every number can be typed in any unit and is converted when the unit changes.
- A field that is empty is blank: it has no value yet.
- A (?) beside a title or a field gives a short note when the mouse rests on it; a click shows it at once.
2 Installation and licence#
2.1 System requirements#
| Item | Requirement |
|---|---|
| Operating system | Windows 10 or Windows 11, 64-bit |
| Processor | Dual core, 1.8 GHz or faster |
| Memory | 4 GB; 8 GB recommended |
| Disk | 1 GB free |
| Screen | 1280 x 768 or larger |
| Internet | Needed to activate the licence, unless an offline file is used |
2.2 Installing#
- Start the Flowmax Setup application.
- Read the information of the first page and press Next if you agree.
- Choose whether a shortcut is put on the desktop.
- Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.
2.3 Activating the licence#
The first time FlowMax starts it shows the licence window.
- Activate License asks for the licence key that came with the purchase.
- Without internet, Offline license file writes a request to send to support, and Activate License reads the file that comes back.
FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.
What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.
2.4 Help and examples#
The File menu holds them, for the mode the project is in:
- Help File opens the user guide of the mode, Training Manual its training manual: from the folder docs beside the program, or, when they are not installed, from the tutorials page of processtool.net.
- Show Example opens the example projects of the mode, in the folder examples beside the program. The start window lists them all under Examples.
- About Flowmax gives the version and the licence.
The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.
3 The window#
3.1 The start screen#

- Liquid opens an empty sheet for a liquid, in steady state and transient. It starts with water, flows in m³/h, pressures in bar, Darcy-Weisbach and the Plot drawing mode; Fluid, Units and Setting change them (chapter 5).
- Gas / multiphase opens a sheet of the Gas & Multiphase mode, which has a guide of its own.
- Open... opens a project file. A FlowMax project is one file with the ending .flmx; an EPANET file opens the same way (section 11.4).
- Examples lists the example projects installed beside the program, in the folder examples.
- Recent lists the last projects with their folder and when each was opened. One click opens a project.
A fire water system starts from the same sheet: litres a minute under Units, Hazen-Williams under Setting, Advanced, and Isometric under Setting, Display, Other (section 5.3).
3.2 The main window#

| Part | What it is |
|---|---|
| Ribbon (1) | The pages Home, Tools, Transient and Reports, and File at the left. Each page is in groups, each named under it |
| Label selectors (2) | What is written beside every link and every node: two values each, one above the other (section 7.3) |
| Equipment strip (3) | Everything that is placed on the sheet. Rest the mouse on a square to read its name (section 3.5) |
| Flowsheet (4) | The sheet the model is drawn on. Its tab, Main Flowsheet, names it |
| Panel at the right (5) | Properties: the inputs and, after a run, the results of the element selected. Elements: every element of the model by kind (section 3.7) |
| Status bar (6) | A coloured label says where the model stands: Missing inputs - see why in red, Ready to run in blue, Solved in green with the time of the run and how long it took, Solved with warnings or with errors in amber, Not solved - see why in red. Click it for the list. At the right it counts the links and the nodes |
| Overview map (7) | The whole model, and in a red frame the part of it that is in view. Drag the frame to move the view. The top edge of the map can be dragged to make it taller |
| Title bar | Save, Undo and Redo, whatever the page |
| Tools of the sheet | A strip at the left edge of the sheet: Select Area, Select All, Scrolling, Zoom Area, Copy, Paste |
| Zoom | At the bottom right of the sheet: Zoom Out, a slider from 25 to 200 %, Zoom In, the scale list and Fit |
| Command | What it does |
|---|---|
| Select Area | Selects the elements inside a rectangle drawn on the sheet. The menu of the right mouse button then acts on all of them (section 4.4) |
| Select All | Selects every element, to move, copy or delete them together |
| Scrolling | Leaves the drawing tool: the mouse then moves the sheet and selects |
| Zoom Area | Draw a rectangle: it fills the window |
| Copy, Paste | Copy the selection and paste it, with all its data |
| Zoom Out, Zoom In, the slider | A step smaller or larger, or any size from 25 to 200 %. The wheel of the mouse zooms about the point under the mouse |
| Fit | Brings the whole model into the window |
3.3 The File menu#
| Command | What it does |
|---|---|
| New | Asks whether to save the changes, then opens FlowMax afresh on its start window and closes this copy |
| Open | Opens a project, or an EPANET file |
| Open Excel | Reads a model from an Excel workbook |
| Save, Save As | Write the project file, under its name or under a new one |
| Setting | The settings of the project, as Setting on the Home page (section 5.3) |
| Help File, Show Example, Training Manual | The user guide of the mode, its example projects and its training manual, beside the program or on processtool.net (section 2.4) |
| About Flowmax | The version of the program and the licence |
| Exit | Closes the program |
Print is on the menu of the right mouse button on an empty part of the sheet (section 4.3).
3.4 The Home page#

| Group | Commands |
|---|---|
| Run | Run solves the steady state. Scenario Case shows on the sheet a case of a scenario that was run (section 9.1) |
| Project | Fluid, Units and Setting: the fluid, the units and the settings of the project (chapter 5). Reset clears the results |
| Results | Links and Nodes: the tables of every link and every node (chapter 8). Graphs (section 10.2) |
| Sheet | Grid: a grid on the sheet. Energy lines, in the Gas & Multiphase mode only: the dashed lines joining the two sides of an exchanger. Setting colors: each element drawn in the colour Setting, Display gives its kind, in the place of one ink |
| Find | Search finds an element by kind and name; Locate shows it on the sheet, Open opens its window |
The Tools page is in chapters 9 and 10, the Reports page in chapter 11. The Transient page belongs to the Transient mode.
3.5 The Equipment strip#

| Square | What it places |
|---|---|
| Pipe, Pipeline | A pipe between two clicks; a line of pipes from a profile of distance and elevation (section 4.6) |
| Valve, Pump | A valve; a pump (sections 6.4, 6.3) |
| General Pressure Drop, Tank | A fixed loss such as a filter or a package; a tank (sections 6.6, 6.5) |
| Spray Nozzle, Non Return Valve | A nozzle on a node; a valve that lets flow one way only |
| Flow meter, Exchanger | A pressure drop drawn as a meter; a heat exchanger (sections 6.6, 6.7) |
| Surge Relief Valve, Air Valve | Protection of the Transient mode; greyed in steady state |
| Accumulator, Surge Tank | Protection of the Transient mode; greyed in steady state |
| Controller | Control of the Transient mode; greyed in steady state |
| Elbow, Tee | A fitting on a node (section 6.2) |
| Reducer, Inline | A fitting on a node; a fitting, an orifice or a fixed loss inside a pipe (section 4.7) |
| Text box, Callout | A note on the sheet; a note that points at an element (section 4.8) |
| Table | A table of results on the sheet (section 4.9) |
3.6 The Properties page#
A click on an element shows its inputs and results on the Properties page of the panel at the right, in two blocks, Inputs and Results, each value with its unit. The page follows the element selected; a double click opens its window.
3.7 The Elements page#
The Elements page lists every element of the model by kind: pipes, pumps, valves, pressure drops, tanks, nozzles, the protection of the Transient mode, the connections, and the groups.
- A box at the top finds an element by its name.
- A click on a name points the element out on the sheet; a double click opens its window.
- Each group made with Define as group stands under Active groups with a tick. Without its tick the group is ignored (section 4.5).
3.8 The mouse#
| Action | What it does |
|---|---|
| Click | Selects an element; its data show on the Properties page |
| Double click | Opens the window of the element |
| Drag an element | Moves it. A node dragged onto another node joins them |
| Drag the sheet | With Scrolling on, moves the view |
| Wheel | Zooms in or out about the point under the mouse |
| Right button | The menu of the element, or of the area selected (section 4.4) |
4 Drawing a model#
A model is links joined at nodes. A link carries flow and loses or gains pressure: a pipe, a pump, a valve, a fixed loss, a tank, a nozzle. A node is where links meet, and where a pressure is reported.
4.1 Placing and joining#
- Place. Press a square of the Equipment strip. A pipe, a pump, a valve or a fixed loss takes two clicks on the sheet, its start and its end. A tank and a nozzle take the node they stand on.
- Join. Click on a node that exists to start or end a link there, or drag the end node of one link onto a node of another. To part two links, drag one of them away from the node they share.
- Fill in. Double-click an element to open its window, type its data and press Confirm. Chapter 6 goes through each window.
- Name. Each new element takes the suffix of its kind and a number (P1, P2, Pump1...). The suffixes are set on the Naming tab of Setting (section 5.3).
Edges A network can be solved when enough is known at its edges. At least one node, or a tank, must fix a pressure. Every other edge is a pressure or a flow. A node left with neither is taken as closed: no flow enters or leaves there.
4.2 Bends, direction and moving#
- Add segment on the menu of a pipe gives it a corner where it was clicked; the corner can be dragged. Delete segments makes the pipe straight again.
- The length of a pipe is the length typed in its window, never the length drawn.
- Reverse direction turns a pipe round. A flow against the way a pipe is drawn is a negative number.
- Insert node cuts a pipe in two at the point clicked.
- An element or an area is moved by dragging it. Copy and Paste repeat a part of the network with all its data.
4.3 The menu of the right mouse button#
Add transient chart and Add to scenario show on these menus in the Transient mode only.

Change icon shows the symbols of the kind: a pressure drop can be drawn as a resistance, a heat exchanger, a packed vessel, a filter, a basket strainer, a drum or a flow meter. The symbol does not change the calculation.
4.4 Working on an area#
Select Area, on the strip at the left of the sheet, then a rectangle drawn on the sheet, selects every element inside it. The menu of the right mouse button then works on all of them.
| Command | What it does |
|---|---|
| Copy selection, Delete selection | Copy or delete every element of the area |
| Ignore, Active | Take the elements out of the calculation, drawn pale, and put them back |
| Define as group | Names the elements as a group (section 4.5) |
| Add path graph | Draws a result along the links of the area (section 10.2) |
| Define parameters: Pipes, Nodes, Nozzles | One value for all the elements of that kind in the area, in the windows below |

Only what is ticked is changed: the length; the inside diameter by schedule and nominal size, or typed; the material and its roughness; the fitting K factor, typed or from Details Fittings.

Node Elevation, Node Temperature, and Node Specification: a pressure or a flow, the same at every node of the area.

Number of nozzles, Required flow, and Nozzle type: a nozzle of the library, or a K factor and a minimum pressure typed.
4.5 Groups, Ignore and Active#
A group made with Define as group is listed on the Elements page with a tick. Without its tick the group is ignored: its elements stay on the sheet, drawn pale, and are left out of the calculation until the tick is set again. A group can be an input of a scenario, so that each case switches it on or off (section 9.1).
Ignore and Active do the same for a selection, or for one element from its own menu, without making a group.
4.6 Pipeline#

| Field | Meaning |
|---|---|
| Prefix | The first letters of the names of the pipes made |
| Left to Right | The way the line is drawn on the sheet |
| Distance, Elevation | The profile, one point a row: the distance along the line and the ground or pipe elevation there |
| Install Pipeline | Places a pipe for each stretch between two points, with its length, and a node at each point with its elevation |
4.7 Inline elements#

Inline puts an element inside a pipe, where it adds to the loss of the pipe without a node of its own. Choose the kind and press Add, then click the pipe.
| Kind | Window |
|---|---|
| Inline fitting | Type and K factor; Select takes a fitting of the library |
| Orifice | Orifice diameter: the loss follows from the bore of the plate and that of the pipe |
| Fixed PD | Pressure drop: a loss that does not change with the flow |

4.8 Text box and Callout#

Text box writes a note on the sheet; Callout writes one that points at an element with an arrow. Type the text, choose its size with - and +, Bold, Italic, Color and Border, press Add and click where it goes. A note is moved by dragging it and edited with a double click.
4.9 Tables on the sheet#

| Field | Meaning |
|---|---|
| Title | Written over the table |
| The list at the right | The kind of element: Pipe, Pump, Valve, Pressure drop, Tank, Spray Nozzle, Node, Calculator, and the four kinds of protection of the Transient mode |
| Objects | The elements, moved from the list of the model to the table with > and <. Search finds one by name, Add all takes every one, Clear empties the list |
| Variables | The rows: the inputs and results to show, chosen the same way |
| Borders | Lines round the cells |
The table is filled again by every run, and shows the case of a scenario that is on show. Show table on the menu of an element makes a table of that one element. Before a run a result reads (Run); an input not given is blank.
5 Fluid, units and settings#
5.1 Fluid#

| Field | Meaning |
|---|---|
| Fluid type | Constant properties: a liquid whose density, viscosity and vapour pressure are the same everywhere. Variable properties: a liquid whose properties follow the temperature the run works out in every node and link (section 5.4). The mode is chosen on the start window: the Fluid window of a liquid offers these two only |
| Select fluid | A fluid of the library at the Temperature typed: its mass density, viscosity and vapour pressure are read from the library |
| Direct properties | The Mass density, the Viscosity and the Vapour pressure as typed: for a fluid the library does not hold |
| Temperature, Mass density, Viscosity, Vapor pressure | The properties used, with their units. With Select fluid only the temperature is typed |
| Specific heat | Shown with Variable properties only: the specific heat of the liquid, one value for every temperature. It comes from the Database when the fluid is chosen (section 10.4) and can be typed over |
| Bulk modulus | Shown in the Transient mode only: the stiffness of the liquid, for the speed of a pressure wave |

The library is kept by Database on the Tools page (section 10.4): a fluid can be added there with its properties at several temperatures.
5.2 Units#

Units on the Home page sets the unit of each quantity: flowrate, pressure, pressure drop, length, diameter, temperature, elevation and head, velocity, mass density, viscosity and power. SI, US and Metric set them all at once; User define frees each list. Changing a unit converts every value of the model; nothing has to be typed again.
Gauge and absolute A pressure unit ending in g, as barg or psig, is a gauge pressure: 0 is the atmosphere. The vapour pressure of the fluid is shown in the same unit, so in a gauge project it reads as a negative number for cold water.
5.3 Setting#
Setting on the Home page, or in the File menu, opens a window of six pages, chosen at its left.
Default Values#

What a new pipe and a new node start with: the Pipe material and its Roughness (with Hazen-Williams, the C coefficient), the Length, the size and the Node elevation. Schedule, size: the schedule and nominal size of a new pipe - at first 40 (reduced list) and 4 in - or User define and an inside diameter typed. Kept with the project.
Unit System#
The same lists as the Units window of section 5.2, with Area and Volume besides.
Display#

| Tab | What it holds |
|---|---|
| Display | The size each kind is drawn at: the width of a pipe, the size of a node, a pump, a valve, a PD, a tank, a nozzle, a fitting, and the size of text, callouts, tables and labels. A click on the line of colour before a kind chooses its colour. Apply redraws the sheet. Pipe width by its diameter: ticked, a large pipe is drawn wider than a small one; not ticked, every pipe the width of the Pipe row. Not ticked at first |
| Naming | The suffix each new element is named with: P for a pipe, N for a node, Pump, Valve, PD, Tank, Nz for a nozzle, ARV, ACM, SRV, SRG-T, FT, NRV |
| Decimal places | How many figures are shown: General uses, Link Label, Node Label. Large figures, the sheet: a figure of a thousand and more on the labels and the key as a whole number, 137 540, or as a power of ten, 1.3754E5; the first at first, kept with the project |
| Other | Drawing mode: Plot or Isometric. Pipe arrow: the arrow of the way a pipe is drawn. Plot Map display: the overview map. Set background: a picture under the sheet, chosen with Upload, with its Image scale and Image transparency |


Icons Shapes#

The symbol every element of a kind is drawn with: valve, pressure drop, pump, tank, nozzle; and the mark of a node whose pressure is given, whose flow is given, and of a sink. One element can be given another symbol with Change icon.
Color Rule#

A box for the pipes and one for the nodes, each with its Variable, five bands and their limits. Auto Range spreads the bands over the results of the run; without it the limits are typed. Apply colours the sheet by the rule, and a key on the sheet gives the bands. By what they carry belongs to the Gas & Multiphase mode.
Advanced#


| Setting | Meaning |
|---|---|
| Solver: Pressure drop model | Darcy-Weisbach, with the roughness of each pipe, or Hazen-Williams, with its C coefficient |
| Solver: Velocity pressure (NFPA 13, 15) | With Hazen-Williams only. Ticked, a nozzle that passes flow on discharges by its normal pressure: the pressure at its node less the velocity pressure of the pipe bringing it the most flow; the last nozzle of a branch by the total pressure. Not ticked, every nozzle by the total pressure, the usual and more conservative way of NFPA 13. Steady state only. The NFPA calculation of the PDF report shows Pv and Pn then (section 11.1) |
| Solver: Errors | Consider errors and stop calculation, or Ignore errors and proceed with calculation: whether a run with errors keeps its results |
| Calculations: Max number of network solver iterations | The most passes the solver makes, 199 at first |
| Network solution tolerance | When the solver stops: the change of the flows between two passes, as a fraction of the flows, 0.01 at first |
| Minimum Flow, Initial Flow, Min Resistance, Max Resistance | Numerical limits of the solver. Leave them as they are unless a model does not converge |
| Consider blocked links as ignored | A part of the network that no pressure reaches, cut off by closed elements, is left out of the run instead of stopping it, and the run says which. Whatever this setting, a spray system that reaches the supply only through something shut is taken as dry and left out (section 12.2) |
5.4 Variable temperature#
With Variable properties in the Fluid window the run works out a temperature for every node and every link, and gives each link the density, the viscosity and the vapour pressure of the liquid at its own temperature, read from the table of the fluid in the library. The pressures and the flows are then solved again with those properties, until the temperatures no longer change. Nothing else of the model changes: the same elements, the same windows.
| Where | Temperature |
|---|---|
| A node of given pressure, a supply node | The liquid that comes into the network there comes in at the Temperature of the node. A (?) beside the field says so: the field is used only where the flow leaves the node into the network |
| A tank | The liquid leaves the tank at the Temperature of the tank window. A tank that is filled takes the temperature that arrives |
| A junction | The flows that meet are mixed by their mass |
| A pipe, a pump, a valve | The liquid goes through at the temperature it came in with. No heat is lost or gained |
| An exchanger | A Fixed duty heats the liquid when positive and cools it when negative; an Outlet temperature is reached whatever the flow, and the duty is the result (section 6.7) |
| A sink, a node where the flow goes out | The temperature that arrives, worked out by the run |


The results show the temperatures: the Temperature of each node, the Temperature of each pipe and pressure drop element, and for an exchanger its Inlet temperature, Outlet temperature and Duty. They are on the Properties page, in the label of a node and in the Exchanger tab of the Links table (section 8.3). A flowrate is the volume that flows at the temperature of its link: where two flows of different temperatures meet, their masses add up, their volumes nearly so.

- The NPSH available of a pump is worked out with the vapour pressure of the liquid at the inlet temperature of the pump.
- The Transient mode works with constant properties only. Going to the Transient mode sets a fluid of variable properties to constant properties, at the temperature of the Fluid window, and says so.
6 Equipment#
Every element has a Name, which must be its own, and a window that opens with a double click. Confirm writes the window into the model and clears the results. A field typed in the colour of an input can be changed; a grey one is worked out or not used. The surge relief valve, the air valve, the accumulator, the surge tank and the controller belong to the Transient mode and are in its guide; in steady state they are greyed on the Equipment strip. So is the Transient page of the windows below.
6.1 Pipe#

| Field | Meaning |
|---|---|
| Name | Its own name |
| Length | The length of the run. It is typed, never measured from the drawing |
| Schedule, Nominal diameter | A size of the schedule library. The inside diameter follows. A new pipe comes as set in Setting, Default Values: 4 in of 40 (reduced list), schedule 40 from 2 in up, first in the list |
| Inside diameter | Typed, when Schedule is left at User define |
| Material, Roughness | A material of the library gives its roughness; or the roughness is typed. With Hazen-Williams the field is the C Coefficient |
| Fittings, Specify | With Specify ticked, the K factor of the fittings of the run is typed. Without it, Details Fittings opens the list below and the total is worked out |
| Status | Normal, or Closed: nothing flows through a closed pipe. Short pipe matters only in the Transient mode, where it concerns the time step |
A pipe that must carry flow one way only takes a Non Return Valve (section 6.4); in a Hazen-Williams project the pipe window also offers No reverse flow as a status. In the Transient mode the window has a second page, Transient, for the wall of the pipe and the wave speed; the Transient User Guide covers it.

Pick a fitting of the library, give its count and press Add; Delete takes one off the list; Additional K Factor adds a loss the library does not hold. The total is written into the pipe. In a Hazen-Williams project the fittings are given as an Eq length in metres of pipe instead of a K factor.

6.2 Node and fittings on a node#

| Field | Meaning |
|---|---|
| Node ID | The number the program gives it |
| Name, Elevation | Its own name; the height of the point. The static head between two nodes comes from their elevations |
| Temperature | Of the liquid at the node. With Variable properties it is used only where the flow leaves the node into the network (section 5.4) |
| Specification: Pressure | The pressure there is known and typed. The flow in or out is a result |
| Specification: Flow | The flow entering there is known and typed. Tick Sink for a flow that leaves; the tables then show it as a negative Flow In |
| Specification: None | An ordinary junction. Nothing enters or leaves; the pressure is a result |

A node where two pipes meet can carry an Elbow or a Reducer, and one where three meet a Tee. Place the fitting from the Equipment strip on the node. Its window keeps the Node page and adds a page for the fitting, with its type, its angle and the pipes it joins; the K factor comes from the library, or is typed with Override ticked. A reducer between two pipes of one size, or the reverse, is an error of the run.
6.3 Pump#

| Field | Meaning |
|---|---|
| Name, Pump on | Its own name; Yes, or No: a pump that is off passes nothing |
| Specification: Rating | On its curve at its Relative speed: 1 is the speed of the curve, another value moves the curve by the affinity laws. Flow and head are results |
| Specification: Flow set | It delivers the Flow typed; the head it needs is the result, the curve is not used |
| Specification: Pressure set | It holds the pressure typed at its discharge node; the head is the result |
| Specification: Head set | It gives the Head typed, or the pressure rise, by the unit chosen beside it; the flow is the result |
| Efficiency (%) | Used for the power when the curve gives none |
| Enter data | The points of the curve: flow, head and efficiency, with NPSH required and power if known |
| Order | 2 or 3: a polynomial H = A + BQ + CQ² + DQ³ fitted through the points. Points: the curve goes through the points themselves, nothing fitted |
| Specify coefficients | The coefficients A, B, C and D are typed instead of points |
| Extend | Opens the curve in a larger window of its own |

The Optional page holds the design figures of the pump that a datasheet carries: H max and H min, the suction vessel pressure with its maximum and its design value, the maximum suction pressure, the suction design pressure and the estimated shutoff pressure, shown once Calculate max suction pressure is ticked. The Datasheet of the Reports page takes them from this page (section 11.2).
The results of a pump are its flow, head, pressure rise, power, outlet pressure and the NPSH available. A warning is raised when the NPSH available is low, or under the NPSH required of the curve. With Variable properties the NPSH available uses the vapour pressure at the inlet temperature of the pump.
6.4 Valve and non-return valve#

| Field | Meaning |
|---|---|
| Name, Valve on | Its own name; Yes, or No: a valve that is off is shut |
| Specification: Rating | At the Opening (%) typed; its drop is a result |
| Specification: Flow set | Holds a flow through itself, or through another link chosen with Pick...; its opening is the result |
| Specification: Pressure set | Holds the pressure at its downstream node, its upstream node or another node chosen with Pick... |
| Specification: Drop set | Holds the drop across itself |
| Cv, Kv | The capacity of the valve wide open, as Cv or as Kv |
| Valve type | The law between opening and capacity: Linear, Eq Percentage, Quick Opening, or a Valve curve of points |
| View | Draws the law chosen; for a valve curve, opens its table |

Non Return Valve on the Equipment strip places a valve that lets flow one way only: it shuts when the flow would turn back. A control valve that cannot reach its target, because it would have to open beyond 100 %, raises a warning; one asked for a flow the line cannot deliver is left fully open, and the run says so.
6.5 Tank#

A tank fixes the pressure where it stands. Tank elevation is the height of its bottom, Liquid level the depth of liquid over it and Tank pressure the pressure over the liquid: 0 for a tank open to the atmosphere in a gauge project. The diameter, the height and the initial level of the Transient page matter only when the level moves in a transient. With Variable properties the window adds the Temperature of the liquid (section 5.4).
6.6 General pressure drop and flow meter#

A general pressure drop, PD for short, is any equipment known by the pressure it takes at a flow: a filter, a meter, a package. Its loss follows DP = K (Flow)ⁿ. A heat exchanger, or a consumer of a cooling water network, is entered as an Exchanger (section 6.7): the same loss, with a required flow and a heat transfer.
| Field | Meaning |
|---|---|
| Calculate K | K is worked out from a Reference flow and the Reference PD at that flow, with the exponent n |
| Specify K | K value and n value are typed |
| Fixed PD | The element takes the pressure drop typed, whatever the flow |
| PQ Curve | The loss is read from a table of flow against pressure drop; View opens the table |

Flow meter on the Equipment strip places a pressure drop element drawn as a meter. Its window offers Calculate K, Fixed PD and Orifice. Orifice is a plate by ISO 5167-2: the Bore diameter is typed; the Pipe inside diameter is that of the pipe at its inlet, else at its outlet; Pressure taps Flange, Corner or D and D/2. Its loss is the permanent loss of the standard, worked out at the run; after a run the box Orifice plate - ISO 5167-2 gives beta, the discharge coefficient, the expansibility and the pressure loss. A flow meter is also where a controller of the Transient mode measures a flow.

6.7 Exchanger#

An Exchanger is a pressure drop element drawn as a heat exchanger, named E1, E2 and upward. Its Inputs page is that of a PD, with one field more; its Heat Transfer page says what it does to the temperature.
| Field | Meaning |
|---|---|
| Calculate K, Specify K, Fixed PD, PQ Curve | The pressure drop, as for a PD (section 6.6) |
| Required flow | Optional. The flow the exchanger is designed for. The results then give its Overdesign: by how many per cent the flow it receives is over that need. A negative figure is an exchanger that is short |
| No heat transfer | The liquid goes through at the temperature it came in with |
| Fixed duty | The heat given to the liquid, in the power unit of the project: positive heats it, negative cools it |
| Outlet temperature | The temperature the liquid leaves at; the duty is a result |

The Heat Transfer page is used only when the fluid has Variable properties (section 5.4). With constant properties an exchanger is a pressure drop with a required flow.
6.8 Spray nozzle#

| Field | Meaning |
|---|---|
| Name, Nozzle on | Its own name; No shuts the nozzle. A nozzle that is off has no overdesign |
| Select nozzle | A nozzle of the library, with its K factor and minimum pressure; or User define |
| K Factor | Flow = K √pressure, in the flow and pressure units of the project |
| Required flow | The flow the nozzle must give. The results give its Overdesign in per cent |
| Minimum Pressure | A warning is raised when the pressure at the nozzle is under it |
| Number of nozzles | Several equal nozzles at one point, entered as one |
A nozzle discharges to the atmosphere. Where no pressure reaches it - it would draw water in - it is shut for the run and the run says it does not spray. Nozzle Layout on the Tools page lays out the nozzles of a whole tank or roof and inserts them with their pipework (section 10.3). With Hazen-Williams and Velocity pressure (NFPA 13, 15) ticked, a nozzle that passes flow on discharges by its normal pressure (section 5.3).
7 Running and reading results#
7.1 Missing inputs#
The status bar says Missing inputs - see why, in red, until every element has what it needs. Click the label: the window lists each element, under Element, with what it still lacks, under Missing input.
7.2 Running#
When the label reads Ready to run, in blue, press Run on the Home page. A model of a few hundred links is solved at once; a town network of 2 200 links takes about half a minute on an ordinary laptop.
After the run the label reads Solved, in green with the time of the run and how long it took, or Solved with warnings or with errors, in amber (chapter 12). A run can also leave a note: a part of the network left out because nothing reaches it, a control that could not be held. Any change of an input clears the results, and the label returns to Ready to run. While a run goes, Save is refused: the program says so.
7.3 Labels on the sheet#
The two Links selectors and the two Nodes selectors, above the sheet at the right, choose what is written beside every link and node: the name, an input, or a result such as flowrate, velocity, friction loss, pressure drop or pressure.

| Field | Meaning |
|---|---|
| Only pipes | Labels on pipes only, not on pumps, valves and the rest |
| First variable, Second variable: Display | Shows or hides each of the two labels |
| Show unit | Writes the unit after the value |
| Legend | A key on the sheet naming the labels |
Each label stands beside its element, clear of its symbol. The size of the labels is set on the Display page of Setting (section 5.3).
7.4 Colours#
On the Color Rule page of Setting choose the Variable of the pipes and of the nodes and tick Apply: the links and the nodes are coloured by that result in five bands, and a key on the sheet gives the ranges (section 5.3). Setting colors on the Home page only draws each kind in its own colour.
7.5 Results of one element#
The Properties page lists every input and result of the element selected. Show table on its menu puts the same on the sheet. The tables of chapter 8 give the results of every element of a kind at once. With Variable properties the page adds the temperatures, and for an exchanger its duty.

8 The Links and Nodes tables#
Links and Nodes on the Home page open a table with one row for each element.
8.1 The Links table#

| Command | What it does |
|---|---|
| The first list | The kind of element: Pipe, Pump, Valve, Pressure drop, Exchanger, Tank, Spray Nozzle, and the four kinds of protection of the Transient mode |
| All, Inputs, Results | For pipes and nozzles: every column, the inputs only, or the results only |
| Pencil, Save | Open the table for typing, and write it into the model (section 8.2) |
| Round arrows | Fill the table again |
| Find | Shows only the rows whose name holds the letters typed, on every kind |
| Total | How many elements of the kind |
| The arrow at the right | Writes the table to an Excel workbook |
- A click on a row finds the element on the sheet: it is drawn in the colour of a search and brought into the middle of the window when it was not in view. The mark goes when the table is closed.
- A click on a heading sorts the rows.
- Rows can be copied to a spreadsheet, and in the edit mode pasted from one.
- In the edit mode a key typed in a cell replaces what is there, as in a spreadsheet; Enter goes to the next cell.
8.2 Typing in the tables#
The tables of pipes, of spray nozzles, of pressure drop elements and of exchangers can be typed in. The pencil opens the table: the cells that can be typed are in the colour of an input. Save checks the names and the numbers and writes the rows into the model; the results are cleared as after any change. A cell that is no number is left as it was, and Save says so.
| Table | Cells |
|---|---|
| Pipes | Name, length, schedule and nominal size or inside diameter, material and roughness, fittings |
| Spray nozzles | Name, nozzle type, K factor, required flow, minimum pressure, number, status |
| Pressure drop, Exchanger | Name and Mode always, and the Required flow of an exchanger; then what the mode of the row uses: Calculate K - reference flow, reference PD and power coefficient (K is worked out); Specify K - K and the power coefficient; Fixed PD - the pressure drop; PQ Curve - the curve stays in the window |

8.3 The tables of pressure drop elements and exchangers#
| Column | Meaning |
|---|---|
| Name, Upstream node, Downstream node | The element and the nodes it joins |
| Mode | Calculate K, Specify K, Fixed PD or PQ Curve; Orifice, for a flow meter only - the table refuses it for a plain pressure drop |
| Reference flow, Reference PD | The point K is worked out from, in the mode Calculate K |
| K value, Power coefficient | DP = K (Flow)ⁿ |
| Flowrate, Pressure drop, Upstream pressure, Downstream pressure | Results |
| Required flow, Overdesign (%) | Exchanger tab only: the flow the exchanger needs, if given, and by how much the flow received is over it |
| Heat transfer, Inlet and Outlet temperature, Duty | Exchanger tab only: the model of its heat transfer and its value, and the results of a run with Variable properties |
8.4 The Nodes table#

One row a node: its ID, name, elevation, pressure and flow in, and in the Transient mode the extremes of the run. Nodes the program makes for itself, such as the end node of a spray nozzle, are not listed, nor are ignored ones. The pencil opens the names and the elevations for typing, and Save writes them. Find and a click on a row work as in the Links table.
9 Scenario, Adjust and Calculator#

Base scenario Scenario, Adjust and Sizing change the model and work on the base case. If the Scenario Case selector of the Home page shows a case, set it back to Base Scenario first.
9.1 Scenario, type Sets#

A scenario runs the model for a list of cases and tabulates chosen results. Add scenario makes a page; Delete scenario removes it; a project can hold several. The type is chosen in Scenario type.
| Part | What it does |
|---|---|
| Select variable | Chooses the inputs that change from case to case: a demand, an elevation, a pipe size or state, a pump speed or state, a valve opening, a tank level, a property of the fluid, a group |
| Add variable | Chooses the results to tabulate: of a node, a link, or a formula of the Calculator |
| The table | The cases down the side, the inputs and then the results across. The rows Object and Current value name each column and give the value the model has now |
| Add case | Adds a row that starts from the values the model has now. Type the value of each input in the blue cells |
| Duplicate, Remove case | Act on the row that is selected |
| The first column | Type over case1 to give a case a name of its own |
| Run | Solves every case and fills the results. A case that cannot be solved reads not solved, and the message says how many cases were solved |
| Results plot | Draws the results against the cases |
| Enable case selection | Keeps each solved case, so that the Scenario Case selector of the Home page can show any of them on the sheet, in the tables and in the report |
| Apply to model | Writes the inputs of the selected case into the model, which then is that case. It asks first |

The window of Select variable and Add variable lists the elements of the kind chosen in Object type, with a box to search by name; the variables of the element chosen show beside them; > and < move a variable into the list of the scenario and out of it; Select variables closes the window.
9.2 Scenario, type Sensitivity#

One input is varied from a Minimum to a Maximum by a Step size, and the results chosen with Add variable are tabulated at each step. Select variable chooses the input; Object names it. Run and Results plot work as in Sets.
9.3 Adjust#

| Field | Meaning |
|---|---|
| Adjusted variable | Select variable: the input to vary, with an optional Minimum and Maximum |
| Target | Select variable: the result to reach, and the Target value |
| Tolerance, Max. iterations | How close the result must come, and how many runs are allowed |
| Start | Runs the model again and again until the result is within the tolerance; the iterations are listed |
| Apply Solution | Writes the value found into the model |
| Auto Adjust | Makes the search again at every run |
| Add Adjust, Delete Adjust | A project can hold several, one a page |
9.4 Calculator#

The Calculator keeps named formulas in the results of the model, and works them out again at every run.
| Field | Meaning |
|---|---|
| Add variable | Brings in, as var1, var2..., a value of an element or of the fluid, or under General a figure of the whole network: the least and the greatest pressure of the nodes, flow of the pipes and velocity, the least overdesign of the nozzles |
| Formula: Name, the expression, Add | A formula of the variables, with a name of its own |
| What a formula may hold | + - * / ^ and brackets; sqrt, sin, cos, tan, exp, abs; log, the natural logarithm, and log10; min, max and avg, the average, of a list such as max(var1, var2, var3) |
| ? | Opens a short guide to formulas |
| Output | Each formula and its value; Edit and Delete act on the one selected |
| Add Calculator, Delete Calculator | Several calculators, one a page |
A formula can be shown in a table on the sheet, tabulated by a scenario and used as the target of Adjust.
10 Sizing, graphs, nozzles and the database#
10.1 Pipe sizing#

| Page | What it holds |
|---|---|
| Set up | Sizing Method: Simple, Genetic Algorithm or Fire Water GA. With Simple: Check the sizes with a Run (ticked at first): the sizes are run on a copy, a pipe that fails goes one size up, up to five runs. Criteria set, with To all pipes, To the pipes selected and Criteria sets.... Pipes set: each pipe with its Phase, Criteria set and Limits now. Diameter set: the sizes allowed, with their cost. The genetic methods keep their Constraints |
| Results | A line that sums the sizing up, the Total cost, and for each pipe its phase, size now and sized, inside diameter, velocity, friction loss a 100 length units, ρv², Set by and Meets; a figure past its limit in red. Generate report and Refresh at the foot |
| Parameters | The genetic methods only, greyed with Simple: Population size, Number of iterations, Mutation rate, and the penalties for a pressure or a velocity out of its limits |
| Autosize, Apply | Run the search, and write the sizes found into the model |

A criteria set holds a row of limits for each phase - Liquid, Water, Gas, Multiphase: the most velocity, or k/ρⁿ, the least velocity, the most drop a 100 m, the most ρv² and the most Mach. Locked sets come from NORSOK P-001 and API RP 14E; a copy can be changed and kept in the project or in one's library. A pipe takes the row of its phase: in the Liquid mode Water when the fluid is water, else Liquid. A project sized with the old limits keeps them as Limits of this project.

10.2 Graphs#
Graphs is on the Home page.

- Pump-system curve draws the curve of a pump, the curve of the system it works into and the point where they meet. It is also on the menu of a pump.
- Path draws results along a run of links chosen in order. Select x axis var chooses what runs across, such as the length along the line; Add y axis var what is drawn, such as the pressure, the elevation or the head: the hydraulic profile of a line. Add path graph on the menu of a selected area makes one from it.
- Generate draws the graph; Extend opens it in a window of its own. The right mouse button on a graph offers Print and Copy as image; in the window of Extend, also View data and Edit chart title.
- Add Graph and Delete Graph: a project can hold several graphs, one a page.

10.3 Nozzle Layout#

| Field | Meaning |
|---|---|
| Shape type | Cylinder: the shell of a tank. Rectangle: a flat area, a roof or a deck |
| The tank, the surface | Its size; Duty on the shell area or another surface; the Flow density to apply |
| The nozzle | Its K value; for a cylinder the distance Header to ring; for a rectangle the spray angle and standoff |
| The rings, the grid | How many rings and nozzles a ring, or columns and rows; Auto layout finds them |
| Results, Geometry | The number of nozzles, the pressure at a nozzle, the flow of each and in all; the spacings and overlap |
| Design rules | The limits the layout is checked against: pressures, distances between rings and between nozzles |
| Copy image, Insert | A picture of the layout; Insert builds it on the sheet |
| Add Arrangement, Delete Arrangement | Several layouts, one a page |


Insert asks how to build the layout - for a rectangle a tree or a grid of pipes; whether to size the pipework as it is inserted, from which material and schedule and for which velocity - and a click on the sheet places the nozzles, the rings and the feed pipe as ordinary elements, with a supply node at the pressure the layout needs.
10.4 Database#

| Page | What it keeps |
|---|---|
| Fluid data | Each fluid with its density, viscosity and vapour pressure at several temperatures, and its Specific heat, one value |
| Piping material | Each material with its roughness, its C coefficient for Hazen-Williams, and its modulus of elasticity for the Transient mode |
| Piping schedule | Each schedule with its sizes: nominal, outside and inside diameter |
| Fittings | Each fitting with its K factor |
| Nozzles | Each spray nozzle with its K factor and its minimum pressure |
| Import db, Export db | Read or write the whole library as a file |
Add, Edit and Delete under each list add an entry, change it or remove it. The libraries belong to the installation, so every project sees them.
The Specific heat under the table of the Fluid data page is the one value of the fluid selected. A value typed there is kept with the project and is taken by the Fluid window when that fluid is chosen.

11 Files and reports#

11.1 PDF Report#

PDF Report opens Report generation. The Project name, Project ref, Revision, Date, Prepared by and Company are those of Project information (section 11.3); changed here, they are kept with the project. Tick the sections - Fluid data, Nodes, Piping details, Pumps, Pumps Curves, Valves, General pressure drop, Tanks, Nozzle Spray, Piping Fittings, the NFPA 13 / 15 calculation with Hazen-Williams, and the Transient charts in the Transient mode. Tick Add under Notes to add the text typed below it. Generate report asks where to write the file.
The PDF has the FlowMax cover, a contents page, the basis of the calculation, a section for each part ticked with the inputs and results of every element, and the messages of the run; the company logo chosen in the Datasheets window stands on its cover and at the head of every page. When a case of a scenario is on show, the report is that of the case.
NFPA 13 / 15 calculation, offered with Hazen-Williams in steady state and ticked then, adds the hydraulic calculation in NFPA's form after the other sections: its basis - the Hazen-Williams formula of NFPA 13 and the method of the nozzles - the nozzles flowing with their K, total pressure Pt and flow, and with the velocity pressure of Setting, Advanced their Pv and normal pressure Pn; the pipes with their flow, bore, C, length, fittings as an equivalent length, friction a unit of length, friction loss Pf and pressure of elevation Pe.
11.2 Datasheet, Excel and Screenshot#
| Command | What it does |
|---|---|
| Datasheet | Opens the Datasheets window: the datasheets of the pumps, the control valves and the orifices |
| Excel | A workbook: Summary, Equipment list, Line list, a sheet for each kind as the tables show it, Equipment data and Notes. On the base case only |
| Screenshot | The flowsheet in a drawing frame, as a PDF file |

- The window lists the pumps, the control valves and the orifices, what each holds and the cases its sheet will have, a tick each.
- Work out the other cases gives a valve Max and Min cases, 110 % and 30 % at first, and a pump a Rated case, 110 %. The network is solved again with every flow it is given at that share, and the model is put back after. An element on its curve, at an opening or given its bore has one case, Rating.
- Design pressure and temperature, estimated: the highest operating pressure plus 10 %, at least 1 bar, and the highest operating temperature plus 25 °C, rounded up.
- Company logo: Choose... a picture, Remove it. It stands on the datasheets and on the PDF report.
- Generate asks where to save and writes the datasheets in Excel and in PDF, with Stop while it works. Former pump sheet... opens the pump datasheet window of before.
11.3 Project information#

Project information, the last command of the Reports page, holds the Project name, Project ref, Revision, Date, Prepared by and Company, and the company logo: the PDF report, the datasheets, the workbook and the screenshot carry them.
11.4 Project files and other programs#
- A project is one .flmx file: the model, its settings, its scenarios, adjusts, calculators, graphs, tables and notes, the criteria sets of the pipe sizing, the datasheet cases and margins, the company logo, and in the Transient mode the controllers, charts and forces.
- Open reads an EPANET file (.inp) and makes a FlowMax project of it.
- Open Excel reads a model from an Excel workbook.
- Save the project under a new name with Save As before a change that cannot be undone.
12 Messages#
12.1 Warnings and errors of a run#

Click the label on the status bar after a run. The list has two pages, Errors and Warnings, each line with the name of the element; a click shows the element on the sheet.
| Message | Kind | What it means |
|---|---|---|
| Pressure below the vapour pressure : the liquid may vaporize | Error | The pressure at a node is under the vapour pressure of the fluid |
| Pressure drop across the pump | Error | The pump is driven beyond the end of its curve and takes pressure instead of giving it |
| Pressure rise across the valve, Pressure rise across the pressure drop | Error | The flow goes backwards through the element |
| Inlet and outlet nodes are at different elevations | Error | The two nodes of a pump, a valve or a fixed loss must stand at one elevation |
| Fitting type does not match the diameter change | Error | A reducer between two pipes of one size, or the reverse |
| NPSHa is low (less than 2 m), NPSHa is lower than NPSHr | Warning | The suction of a pump is close to cavitation |
| Required valve opening is greater than 100 % | Warning | A control valve cannot reach its target |
| Overdesign is negative (less than the required flow) | Warning | A nozzle receives less than its required flow |
| Nozzle pressure is below its minimum pressure | Warning | A nozzle is under the least pressure it works at |
| The nozzle does not spray : no pressure reaches it | Warning | The pressure at the nozzle is under the atmosphere; it is shut for the run |
| Flow is in the opposite direction | Warning | The flow in a pipe goes against the way it was drawn. The result is right; the sign is negative |
12.2 Notes of a run#
| Note | What it means |
|---|---|
| Elements and nodes left with no route to a pressure boundary | With Consider blocked links as ignored : a part cut off by shut elements is left out of the run |
| The spray system behind ... is dry | A spray system reached only through something shut is left out of the run |
| ... cannot hold its setting - it is left fully open | A control valve asked for more than the line delivers |
| Missing inputs | The model is not complete: see the list (section 7.1) |
| Unknown bore of its orifice ; The bore of its orifice is not smaller than its pipe ; No pipe at its inlet or its outlet | A flow meter given as an orifice lacks what ISO 5167-2 needs: the run does not start until it has it (section 6.6) |
If a model does not solve Look first for an edge with neither a pressure nor a flow, for a part of the network cut off from every pressure, and for two pressures fixed with nothing but a closed element between them.
12.3 Before a result is used#
- The status bar reads Solved, and the list of errors is empty.
- Every edge of the network is a pressure or a flow, and the sum of the flows that leave is what was meant.
- The elevations are those of the plant: a pump, a valve and a fixed loss have both nodes at one elevation.
- No pressure is under the vapour pressure of the fluid, and every pump has the NPSH it requires.
- The velocities are those the project allows; the colours show at a glance where they are not.
Next: the Steady-State Training Manual works nine cases from an empty sheet to a report, and the Transient User Guide takes the same model into a transient.
