1 Introduction#

FlowMax has three modes: Liquid, Transient and Gas & Multiphase. This guide is about the Liquid mode in steady state. FlowMax calculates the flow, the pressure and, when asked, the temperature in a network of pipes that carries a liquid. The network is drawn on a sheet as links joined at nodes: pipes, pumps, valves, tanks, fixed losses and spray nozzles. In steady state the program finds the flows and pressures that balance. The same model can then be run in the Transient mode to follow a surge; that mode has a guide of its own, the Transient User Guide.

This guide is a reference. It goes through the window, the drawing of a model, the settings of a project, every piece of equipment, the results and the tables, every tool, the files and the reports, and the messages a run can give. For each window it says what every field means and what every command does. It works no example: the Steady-State Training Manual does that, with nine complete cases and their project files.

The pictures are the windows of the program itself. A red numbered circle on some of them marks a field the training manual speaks of; here it can be passed over.

Part of a reference model of 890 links: one of the three LNG trains of a cooling water network, its six process areas drawn as ladders of exchangers between a supply and a return sub-header.
Figure 1 Part of a reference model of 890 links: one of the three LNG trains of a cooling water network, its six process areas drawn as ladders of exchangers between a supply and a return sub-header.
Table 1 What the steady state does
SubjectWhat FlowMax offers
NetworksBranched and looped networks of any shape, with several sources and several pumps; up to 4 999 links in one model, 40 with a Liquid Lite licence
Pressure dropDarcy-Weisbach with the roughness of the pipe, or Hazen-Williams with its C factor in the form of NFPA 13 and EN 12845, with the velocity pressure of NFPA 13 and 15 if wanted; fittings from a library or as a K factor; an orifice plate by ISO 5167-2
TemperatureA liquid of variable properties: the temperature of every node and link, from the supplies, the mixing of the flows and the exchangers; the density, the viscosity and the vapour pressure follow it
EquipmentPumps on their curve or given a flow, a pressure or a head; valves at an opening or given a flow, a pressure or a drop; non-return valves, tanks, heat exchangers and other fixed losses, flow meters and orifice plates, spray nozzles
Fire waterSpray nozzles with their K factor and required flow; a tool that lays nozzles out on a tank or a roof and inserts them with their pipework
StudiesScenarios, goal seek (Adjust), formulas in the results (Calculator), pipe sizing against criteria sets, graphs along a path, pump against system
OutputResults on the sheet, in tables and in graphs; a PDF report; an Excel workbook with a summary, an equipment list and a line list; datasheets of the pumps, the control valves and the orifices, in Excel and PDF
ExchangeEPANET files opened as FlowMax projects

1.1 How the guide is written#

2 Installation and licence#

2.1 System requirements#

Table 2 What FlowMax needs
ItemRequirement
Operating systemWindows 10 or Windows 11, 64-bit
ProcessorDual core, 1.8 GHz or faster
Memory4 GB; 8 GB recommended
Disk1 GB free
Screen1280 x 768 or larger
InternetNeeded to activate the licence, unless an offline file is used

2.2 Installing#

  1. Start the Flowmax Setup application.
  2. Read the information of the first page and press Next if you agree.
  3. Choose whether a shortcut is put on the desktop.
  4. Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.

2.3 Activating the licence#

The first time FlowMax starts it shows the licence window.

FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.

What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.

2.4 Help and examples#

The File menu holds them, for the mode the project is in:

The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.

3 The window#

3.1 The start screen#

The start window: the two kinds of new project above the projects opened lately; Open and Examples at the left.
Figure 2 The start window: the two kinds of new project above the projects opened lately; Open and Examples at the left.

A fire water system starts from the same sheet: litres a minute under Units, Hazen-Williams under Setting, Advanced, and Isometric under Setting, Display, Other (section 5.3).

3.2 The main window#

The FlowMax window with a small model solved and a pipe selected. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.
Figure 3 The FlowMax window with a small model solved and a pipe selected. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.
Table 3 The parts of the window
PartWhat it is
Ribbon (1)The pages Home, Tools, Transient and Reports, and File at the left. Each page is in groups, each named under it
Label selectors (2)What is written beside every link and every node: two values each, one above the other (section 7.3)
Equipment strip (3)Everything that is placed on the sheet. Rest the mouse on a square to read its name (section 3.5)
Flowsheet (4)The sheet the model is drawn on. Its tab, Main Flowsheet, names it
Panel at the right (5)Properties: the inputs and, after a run, the results of the element selected. Elements: every element of the model by kind (section 3.7)
Status bar (6)A coloured label says where the model stands: Missing inputs - see why in red, Ready to run in blue, Solved in green with the time of the run and how long it took, Solved with warnings or with errors in amber, Not solved - see why in red. Click it for the list. At the right it counts the links and the nodes
Overview map (7)The whole model, and in a red frame the part of it that is in view. Drag the frame to move the view. The top edge of the map can be dragged to make it taller
Title barSave, Undo and Redo, whatever the page
Tools of the sheetA strip at the left edge of the sheet: Select Area, Select All, Scrolling, Zoom Area, Copy, Paste
ZoomAt the bottom right of the sheet: Zoom Out, a slider from 25 to 200 %, Zoom In, the scale list and Fit
Table 4 The tools of the sheet and the zoom
CommandWhat it does
Select AreaSelects the elements inside a rectangle drawn on the sheet. The menu of the right mouse button then acts on all of them (section 4.4)
Select AllSelects every element, to move, copy or delete them together
ScrollingLeaves the drawing tool: the mouse then moves the sheet and selects
Zoom AreaDraw a rectangle: it fills the window
Copy, PasteCopy the selection and paste it, with all its data
Zoom Out, Zoom In, the sliderA step smaller or larger, or any size from 25 to 200 %. The wheel of the mouse zooms about the point under the mouse
FitBrings the whole model into the window

3.3 The File menu#

Table 5 The commands of the File menu
CommandWhat it does
NewAsks whether to save the changes, then opens FlowMax afresh on its start window and closes this copy
OpenOpens a project, or an EPANET file
Open ExcelReads a model from an Excel workbook
Save, Save AsWrite the project file, under its name or under a new one
SettingThe settings of the project, as Setting on the Home page (section 5.3)
Help File, Show Example, Training ManualThe user guide of the mode, its example projects and its training manual, beside the program or on processtool.net (section 2.4)
About FlowmaxThe version of the program and the licence
ExitCloses the program

Print is on the menu of the right mouse button on an empty part of the sheet (section 4.3).

3.4 The Home page#

The Home page of the ribbon.
Figure 4 The Home page of the ribbon.
Table 6 The Home page
GroupCommands
RunRun solves the steady state. Scenario Case shows on the sheet a case of a scenario that was run (section 9.1)
ProjectFluid, Units and Setting: the fluid, the units and the settings of the project (chapter 5). Reset clears the results
ResultsLinks and Nodes: the tables of every link and every node (chapter 8). Graphs (section 10.2)
SheetGrid: a grid on the sheet. Energy lines, in the Gas & Multiphase mode only: the dashed lines joining the two sides of an exchanger. Setting colors: each element drawn in the colour Setting, Display gives its kind, in the place of one ink
FindSearch finds an element by kind and name; Locate shows it on the sheet, Open opens its window

The Tools page is in chapters 9 and 10, the Reports page in chapter 11. The Transient page belongs to the Transient mode.

3.5 The Equipment strip#

The Equipment strip, in groups with a line between two.
Figure 5 The Equipment strip, in groups with a line between two.
Table 7 The squares of the Equipment strip, from the top
SquareWhat it places
Pipe, PipelineA pipe between two clicks; a line of pipes from a profile of distance and elevation (section 4.6)
Valve, PumpA valve; a pump (sections 6.4, 6.3)
General Pressure Drop, TankA fixed loss such as a filter or a package; a tank (sections 6.6, 6.5)
Spray Nozzle, Non Return ValveA nozzle on a node; a valve that lets flow one way only
Flow meter, ExchangerA pressure drop drawn as a meter; a heat exchanger (sections 6.6, 6.7)
Surge Relief Valve, Air ValveProtection of the Transient mode; greyed in steady state
Accumulator, Surge TankProtection of the Transient mode; greyed in steady state
ControllerControl of the Transient mode; greyed in steady state
Elbow, TeeA fitting on a node (section 6.2)
Reducer, InlineA fitting on a node; a fitting, an orifice or a fixed loss inside a pipe (section 4.7)
Text box, CalloutA note on the sheet; a note that points at an element (section 4.8)
TableA table of results on the sheet (section 4.9)

3.6 The Properties page#

A click on an element shows its inputs and results on the Properties page of the panel at the right, in two blocks, Inputs and Results, each value with its unit. The page follows the element selected; a double click opens its window.

3.7 The Elements page#

The Elements page lists every element of the model by kind: pipes, pumps, valves, pressure drops, tanks, nozzles, the protection of the Transient mode, the connections, and the groups.

3.8 The mouse#

Table 8 The mouse on the sheet
ActionWhat it does
ClickSelects an element; its data show on the Properties page
Double clickOpens the window of the element
Drag an elementMoves it. A node dragged onto another node joins them
Drag the sheetWith Scrolling on, moves the view
WheelZooms in or out about the point under the mouse
Right buttonThe menu of the element, or of the area selected (section 4.4)

4 Drawing a model#

A model is links joined at nodes. A link carries flow and loses or gains pressure: a pipe, a pump, a valve, a fixed loss, a tank, a nozzle. A node is where links meet, and where a pressure is reported.

4.1 Placing and joining#

  1. Place. Press a square of the Equipment strip. A pipe, a pump, a valve or a fixed loss takes two clicks on the sheet, its start and its end. A tank and a nozzle take the node they stand on.
  2. Join. Click on a node that exists to start or end a link there, or drag the end node of one link onto a node of another. To part two links, drag one of them away from the node they share.
  3. Fill in. Double-click an element to open its window, type its data and press Confirm. Chapter 6 goes through each window.
  4. Name. Each new element takes the suffix of its kind and a number (P1, P2, Pump1...). The suffixes are set on the Naming tab of Setting (section 5.3).

Edges A network can be solved when enough is known at its edges. At least one node, or a tank, must fix a pressure. Every other edge is a pressure or a flow. A node left with neither is taken as closed: no flow enters or leaves there.

4.2 Bends, direction and moving#

4.3 The menu of the right mouse button#

Table 9 The menu of the right mouse button
OnCommands
A linkProperties opens its window. Show table puts a table of it on the sheet. Add tag writes its name on the sheet beside it. Copy data and Paste carry the data of one element to another of its kind. Select label opens the Labels window. Change icon chooses its symbol. Ignore takes it out of the calculation, Active puts it back. Delete removes it
A nodeProperties, Show table, Copy data, Paste, Select label, Change icon, Ignore and Active, as for a link
A pipeBesides: Insert node, Reverse direction, Add segment, Delete segments
A pumpBesides: Add Pump-system curve draws the pump against its system (section 10.2)
A selected areaCopy selection, Delete selection, Ignore, Active, Define as group, Add path graph, and under Define parameters: Nodes, Pipes, Nozzles (section 4.4)
The empty sheetPaste, Grid (Hide, Show), Drawing mode (Plot, Isometric), Print, Scale to Fit

Add transient chart and Add to scenario show on these menus in the Transient mode only.

Change icon on a pressure drop element: the symbols it can be drawn with.
Figure 6 Change icon on a pressure drop element: the symbols it can be drawn with.

Change icon shows the symbols of the kind: a pressure drop can be drawn as a resistance, a heat exchanger, a packed vessel, a filter, a basket strainer, a drum or a flow meter. The symbol does not change the calculation.

4.4 Working on an area#

Select Area, on the strip at the left of the sheet, then a rectangle drawn on the sheet, selects every element inside it. The menu of the right mouse button then works on all of them.

Table 10 The commands for a selected area
CommandWhat it does
Copy selection, Delete selectionCopy or delete every element of the area
Ignore, ActiveTake the elements out of the calculation, drawn pale, and put them back
Define as groupNames the elements as a group (section 4.5)
Add path graphDraws a result along the links of the area (section 10.2)
Define parameters: Pipes, Nodes, NozzlesOne value for all the elements of that kind in the area, in the windows below
Pipes, for a selected area: tick what is to be set.
Figure 7 Pipes, for a selected area: tick what is to be set.

Only what is ticked is changed: the length; the inside diameter by schedule and nominal size, or typed; the material and its roughness; the fitting K factor, typed or from Details Fittings.

Nodes, for a selected area.
Figure 8 Nodes, for a selected area.

Node Elevation, Node Temperature, and Node Specification: a pressure or a flow, the same at every node of the area.

Nozzles, for a selected area.
Figure 9 Nozzles, for a selected area.

Number of nozzles, Required flow, and Nozzle type: a nozzle of the library, or a K factor and a minimum pressure typed.

4.5 Groups, Ignore and Active#

A group made with Define as group is listed on the Elements page with a tick. Without its tick the group is ignored: its elements stay on the sheet, drawn pale, and are left out of the calculation until the tick is set again. A group can be an input of a scenario, so that each case switches it on or off (section 9.1).

Ignore and Active do the same for a selection, or for one element from its own menu, without making a group.

4.6 Pipeline#

Pipeline: a line drawn from a profile.
Figure 10 Pipeline: a line drawn from a profile.
Table 11 The fields of Pipeline
FieldMeaning
PrefixThe first letters of the names of the pipes made
Left to RightThe way the line is drawn on the sheet
Distance, ElevationThe profile, one point a row: the distance along the line and the ground or pipe elevation there
Install PipelinePlaces a pipe for each stretch between two points, with its length, and a node at each point with its elevation

4.7 Inline elements#

Inline: the three kinds of element that sit inside a pipe.
Figure 11 Inline: the three kinds of element that sit inside a pipe.

Inline puts an element inside a pipe, where it adds to the loss of the pipe without a node of its own. Choose the kind and press Add, then click the pipe.

Table 12 The three inline elements
KindWindow
Inline fittingType and K factor; Select takes a fitting of the library
OrificeOrifice diameter: the loss follows from the bore of the plate and that of the pipe
Fixed PDPressure drop: a loss that does not change with the flow
The window of an inline fitting. The pipe it sits in is named at the top.
Figure 12 The window of an inline fitting. The pipe it sits in is named at the top.

4.8 Text box and Callout#

Text box: the text, its size, bold, italic, colour and a border.
Figure 13 Text box: the text, its size, bold, italic, colour and a border.

Text box writes a note on the sheet; Callout writes one that points at an element with an arrow. Type the text, choose its size with - and +, Bold, Italic, Color and Border, press Add and click where it goes. A note is moved by dragging it and edited with a double click.

4.9 Tables on the sheet#

Table: what a table on the sheet shows.
Figure 14 Table: what a table on the sheet shows.
Table 13 The fields of a table on the sheet
FieldMeaning
TitleWritten over the table
The list at the rightThe kind of element: Pipe, Pump, Valve, Pressure drop, Tank, Spray Nozzle, Node, Calculator, and the four kinds of protection of the Transient mode
ObjectsThe elements, moved from the list of the model to the table with > and <. Search finds one by name, Add all takes every one, Clear empties the list
VariablesThe rows: the inputs and results to show, chosen the same way
BordersLines round the cells

The table is filled again by every run, and shows the case of a scenario that is on show. Show table on the menu of an element makes a table of that one element. Before a run a result reads (Run); an input not given is blank.

5 Fluid, units and settings#

5.1 Fluid#

The Fluid window.
Figure 15 The Fluid window.
Table 14 The fields of the Fluid window
FieldMeaning
Fluid typeConstant properties: a liquid whose density, viscosity and vapour pressure are the same everywhere. Variable properties: a liquid whose properties follow the temperature the run works out in every node and link (section 5.4). The mode is chosen on the start window: the Fluid window of a liquid offers these two only
Select fluidA fluid of the library at the Temperature typed: its mass density, viscosity and vapour pressure are read from the library
Direct propertiesThe Mass density, the Viscosity and the Vapour pressure as typed: for a fluid the library does not hold
Temperature, Mass density, Viscosity, Vapor pressureThe properties used, with their units. With Select fluid only the temperature is typed
Specific heatShown with Variable properties only: the specific heat of the liquid, one value for every temperature. It comes from the Database when the fluid is chosen (section 10.4) and can be typed over
Bulk modulusShown in the Transient mode only: the stiffness of the liquid, for the speed of a pressure wave
The Fluid window with Variable properties: the Specific heat is added.
Figure 16 The Fluid window with Variable properties: the Specific heat is added.

The library is kept by Database on the Tools page (section 10.4): a fluid can be added there with its properties at several temperatures.

5.2 Units#

The Units window.
Figure 17 The Units window.

Units on the Home page sets the unit of each quantity: flowrate, pressure, pressure drop, length, diameter, temperature, elevation and head, velocity, mass density, viscosity and power. SI, US and Metric set them all at once; User define frees each list. Changing a unit converts every value of the model; nothing has to be typed again.

Gauge and absolute A pressure unit ending in g, as barg or psig, is a gauge pressure: 0 is the atmosphere. The vapour pressure of the fluid is shown in the same unit, so in a gauge project it reads as a negative number for cold water.

5.3 Setting#

Setting on the Home page, or in the File menu, opens a window of six pages, chosen at its left.

Default Values#

Setting, Default Values.
Figure 18 Setting, Default Values.

What a new pipe and a new node start with: the Pipe material and its Roughness (with Hazen-Williams, the C coefficient), the Length, the size and the Node elevation. Schedule, size: the schedule and nominal size of a new pipe - at first 40 (reduced list) and 4 in - or User define and an inside diameter typed. Kept with the project.

Unit System#

The same lists as the Units window of section 5.2, with Area and Volume besides.

Display#

Setting, Display, its first tab: the size of each kind of object on the sheet.
Figure 19 Setting, Display, its first tab: the size of each kind of object on the sheet.
Table 15 The four tabs of the Display page
TabWhat it holds
DisplayThe size each kind is drawn at: the width of a pipe, the size of a node, a pump, a valve, a PD, a tank, a nozzle, a fitting, and the size of text, callouts, tables and labels. A click on the line of colour before a kind chooses its colour. Apply redraws the sheet. Pipe width by its diameter: ticked, a large pipe is drawn wider than a small one; not ticked, every pipe the width of the Pipe row. Not ticked at first
NamingThe suffix each new element is named with: P for a pipe, N for a node, Pump, Valve, PD, Tank, Nz for a nozzle, ARV, ACM, SRV, SRG-T, FT, NRV
Decimal placesHow many figures are shown: General uses, Link Label, Node Label. Large figures, the sheet: a figure of a thousand and more on the labels and the key as a whole number, 137 540, or as a power of ten, 1.3754E5; the first at first, kept with the project
OtherDrawing mode: Plot or Isometric. Pipe arrow: the arrow of the way a pipe is drawn. Plot Map display: the overview map. Set background: a picture under the sheet, chosen with Upload, with its Image scale and Image transparency
Setting, Display, Other: drawing mode, arrows, map and background.
Figure 20 Setting, Display, Other: drawing mode, arrows, map and background.
Setting, Display, Decimal places: Large figures, the sheet.
Figure 21 Setting, Display, Decimal places: Large figures, the sheet.

Icons Shapes#

Setting, Icons Shapes: the symbol of each kind.
Figure 22 Setting, Icons Shapes: the symbol of each kind.

The symbol every element of a kind is drawn with: valve, pressure drop, pump, tank, nozzle; and the mark of a node whose pressure is given, whose flow is given, and of a sink. One element can be given another symbol with Change icon.

Color Rule#

Setting, Color Rule.
Figure 23 Setting, Color Rule.

A box for the pipes and one for the nodes, each with its Variable, five bands and their limits. Auto Range spreads the bands over the results of the run; without it the limits are typed. Apply colours the sheet by the rule, and a key on the sheet gives the bands. By what they carry belongs to the Gas & Multiphase mode.

Advanced#

Setting, Advanced, the Solver tab.
Figure 24 Setting, Advanced, the Solver tab.
Setting, Advanced, the Calculations tab.
Figure 25 Setting, Advanced, the Calculations tab.
Table 16 The two tabs of the Advanced page
SettingMeaning
Solver: Pressure drop modelDarcy-Weisbach, with the roughness of each pipe, or Hazen-Williams, with its C coefficient
Solver: Velocity pressure (NFPA 13, 15)With Hazen-Williams only. Ticked, a nozzle that passes flow on discharges by its normal pressure: the pressure at its node less the velocity pressure of the pipe bringing it the most flow; the last nozzle of a branch by the total pressure. Not ticked, every nozzle by the total pressure, the usual and more conservative way of NFPA 13. Steady state only. The NFPA calculation of the PDF report shows Pv and Pn then (section 11.1)
Solver: ErrorsConsider errors and stop calculation, or Ignore errors and proceed with calculation: whether a run with errors keeps its results
Calculations: Max number of network solver iterationsThe most passes the solver makes, 199 at first
Network solution toleranceWhen the solver stops: the change of the flows between two passes, as a fraction of the flows, 0.01 at first
Minimum Flow, Initial Flow, Min Resistance, Max ResistanceNumerical limits of the solver. Leave them as they are unless a model does not converge
Consider blocked links as ignoredA part of the network that no pressure reaches, cut off by closed elements, is left out of the run instead of stopping it, and the run says which. Whatever this setting, a spray system that reaches the supply only through something shut is taken as dry and left out (section 12.2)

5.4 Variable temperature#

With Variable properties in the Fluid window the run works out a temperature for every node and every link, and gives each link the density, the viscosity and the vapour pressure of the liquid at its own temperature, read from the table of the fluid in the library. The pressures and the flows are then solved again with those properties, until the temperatures no longer change. Nothing else of the model changes: the same elements, the same windows.

Table 17 Where the temperatures come from
WhereTemperature
A node of given pressure, a supply nodeThe liquid that comes into the network there comes in at the Temperature of the node. A (?) beside the field says so: the field is used only where the flow leaves the node into the network
A tankThe liquid leaves the tank at the Temperature of the tank window. A tank that is filled takes the temperature that arrives
A junctionThe flows that meet are mixed by their mass
A pipe, a pump, a valveThe liquid goes through at the temperature it came in with. No heat is lost or gained
An exchangerA Fixed duty heats the liquid when positive and cools it when negative; an Outlet temperature is reached whatever the flow, and the duty is the result (section 6.7)
A sink, a node where the flow goes outThe temperature that arrives, worked out by the run
The Node window: the (?) beside the Temperature.
Figure 26 The Node window: the (?) beside the Temperature.
The Tank window: the Temperature of its liquid, shown with Variable properties only.
Figure 27 The Tank window: the Temperature of its liquid, shown with Variable properties only.

The results show the temperatures: the Temperature of each node, the Temperature of each pipe and pressure drop element, and for an exchanger its Inlet temperature, Outlet temperature and Duty. They are on the Properties page, in the label of a node and in the Exchanger tab of the Links table (section 8.3). A flowrate is the volume that flows at the temperature of its link: where two flows of different temperatures meet, their masses add up, their volumes nearly so.

A liquid heated from 20 to 45 °C by exchanger E1: the temperature of each node on the sheet.
Figure 28 A liquid heated from 20 to 45 °C by exchanger E1: the temperature of each node on the sheet.

6 Equipment#

Every element has a Name, which must be its own, and a window that opens with a double click. Confirm writes the window into the model and clears the results. A field typed in the colour of an input can be changed; a grey one is worked out or not used. The surge relief valve, the air valve, the accumulator, the surge tank and the controller belong to the Transient mode and are in its guide; in steady state they are greyed on the Equipment strip. So is the Transient page of the windows below.

6.1 Pipe#

The Pipe window.
Figure 29 The Pipe window.
Table 18 The fields of a pipe
FieldMeaning
NameIts own name
LengthThe length of the run. It is typed, never measured from the drawing
Schedule, Nominal diameterA size of the schedule library. The inside diameter follows. A new pipe comes as set in Setting, Default Values: 4 in of 40 (reduced list), schedule 40 from 2 in up, first in the list
Inside diameterTyped, when Schedule is left at User define
Material, RoughnessA material of the library gives its roughness; or the roughness is typed. With Hazen-Williams the field is the C Coefficient
Fittings, SpecifyWith Specify ticked, the K factor of the fittings of the run is typed. Without it, Details Fittings opens the list below and the total is worked out
StatusNormal, or Closed: nothing flows through a closed pipe. Short pipe matters only in the Transient mode, where it concerns the time step

A pipe that must carry flow one way only takes a Non Return Valve (section 6.4); in a Hazen-Williams project the pipe window also offers No reverse flow as a status. In the Transient mode the window has a second page, Transient, for the wall of the pipe and the wave speed; the Transient User Guide covers it.

Details Fittings: the fittings of the library with their count; the total K factor is worked out.
Figure 30 Details Fittings: the fittings of the library with their count; the total K factor is worked out.

Pick a fitting of the library, give its count and press Add; Delete takes one off the list; Additional K Factor adds a loss the library does not hold. The total is written into the pipe. In a Hazen-Williams project the fittings are given as an Eq length in metres of pipe instead of a K factor.

The Pipe window of a Hazen-Williams project: C coefficient, equivalent length and the No reverse flow status.
Figure 31 The Pipe window of a Hazen-Williams project: C coefficient, equivalent length and the No reverse flow status.

6.2 Node and fittings on a node#

The Node window, here with a pressure specified.
Figure 32 The Node window, here with a pressure specified.
Table 19 The fields of a node
FieldMeaning
Node IDThe number the program gives it
Name, ElevationIts own name; the height of the point. The static head between two nodes comes from their elevations
TemperatureOf the liquid at the node. With Variable properties it is used only where the flow leaves the node into the network (section 5.4)
Specification: PressureThe pressure there is known and typed. The flow in or out is a result
Specification: FlowThe flow entering there is known and typed. Tick Sink for a flow that leaves; the tables then show it as a negative Flow In
Specification: NoneAn ordinary junction. Nothing enters or leaves; the pressure is a result
A node that carries an elbow: the Node page and the Elbow page.
Figure 33 A node that carries an elbow: the Node page and the Elbow page.

A node where two pipes meet can carry an Elbow or a Reducer, and one where three meet a Tee. Place the fitting from the Equipment strip on the node. Its window keeps the Node page and adds a page for the fitting, with its type, its angle and the pipes it joins; the K factor comes from the library, or is typed with Override ticked. A reducer between two pipes of one size, or the reverse, is an error of the run.

6.3 Pump#

The Pump window on its Inputs page, on its curve (Rating).
Figure 34 The Pump window on its Inputs page, on its curve (Rating).
Table 20 The fields of a pump
FieldMeaning
Name, Pump onIts own name; Yes, or No: a pump that is off passes nothing
Specification: RatingOn its curve at its Relative speed: 1 is the speed of the curve, another value moves the curve by the affinity laws. Flow and head are results
Specification: Flow setIt delivers the Flow typed; the head it needs is the result, the curve is not used
Specification: Pressure setIt holds the pressure typed at its discharge node; the head is the result
Specification: Head setIt gives the Head typed, or the pressure rise, by the unit chosen beside it; the flow is the result
Efficiency (%)Used for the power when the curve gives none
Enter dataThe points of the curve: flow, head and efficiency, with NPSH required and power if known
Order2 or 3: a polynomial H = A + BQ + CQ² + DQ³ fitted through the points. Points: the curve goes through the points themselves, nothing fitted
Specify coefficientsThe coefficients A, B, C and D are typed instead of points
ExtendOpens the curve in a larger window of its own
The same pump given its flow (Flow set): no curve is needed.
Figure 35 The same pump given its flow (Flow set): no curve is needed.

The Optional page holds the design figures of the pump that a datasheet carries: H max and H min, the suction vessel pressure with its maximum and its design value, the maximum suction pressure, the suction design pressure and the estimated shutoff pressure, shown once Calculate max suction pressure is ticked. The Datasheet of the Reports page takes them from this page (section 11.2).

The results of a pump are its flow, head, pressure rise, power, outlet pressure and the NPSH available. A warning is raised when the NPSH available is low, or under the NPSH required of the curve. With Variable properties the NPSH available uses the vapour pressure at the inlet temperature of the pump.

6.4 Valve and non-return valve#

The Valve window.
Figure 36 The Valve window.
Table 21 The fields of a valve
FieldMeaning
Name, Valve onIts own name; Yes, or No: a valve that is off is shut
Specification: RatingAt the Opening (%) typed; its drop is a result
Specification: Flow setHolds a flow through itself, or through another link chosen with Pick...; its opening is the result
Specification: Pressure setHolds the pressure at its downstream node, its upstream node or another node chosen with Pick...
Specification: Drop setHolds the drop across itself
Cv, KvThe capacity of the valve wide open, as Cv or as Kv
Valve typeThe law between opening and capacity: Linear, Eq Percentage, Quick Opening, or a Valve curve of points
ViewDraws the law chosen; for a valve curve, opens its table
A valve curve: Cv in per cent against opening; Generate draws it.
Figure 37 A valve curve: Cv in per cent against opening; Generate draws it.

Non Return Valve on the Equipment strip places a valve that lets flow one way only: it shuts when the flow would turn back. A control valve that cannot reach its target, because it would have to open beyond 100 %, raises a warning; one asked for a flow the line cannot deliver is left fully open, and the run says so.

6.5 Tank#

The Tank window.
Figure 38 The Tank window.

A tank fixes the pressure where it stands. Tank elevation is the height of its bottom, Liquid level the depth of liquid over it and Tank pressure the pressure over the liquid: 0 for a tank open to the atmosphere in a gauge project. The diameter, the height and the initial level of the Transient page matter only when the level moves in a transient. With Variable properties the window adds the Temperature of the liquid (section 5.4).

6.6 General pressure drop and flow meter#

The Pressure drop window.
Figure 39 The Pressure drop window.

A general pressure drop, PD for short, is any equipment known by the pressure it takes at a flow: a filter, a meter, a package. Its loss follows DP = K (Flow)ⁿ. A heat exchanger, or a consumer of a cooling water network, is entered as an Exchanger (section 6.7): the same loss, with a required flow and a heat transfer.

Table 22 The fields of a pressure drop element
FieldMeaning
Calculate KK is worked out from a Reference flow and the Reference PD at that flow, with the exponent n
Specify KK value and n value are typed
Fixed PDThe element takes the pressure drop typed, whatever the flow
PQ CurveThe loss is read from a table of flow against pressure drop; View opens the table
The PQ curve of a PD: pressure drop against flowrate.
Figure 40 The PQ curve of a PD: pressure drop against flowrate.

Flow meter on the Equipment strip places a pressure drop element drawn as a meter. Its window offers Calculate K, Fixed PD and Orifice. Orifice is a plate by ISO 5167-2: the Bore diameter is typed; the Pipe inside diameter is that of the pipe at its inlet, else at its outlet; Pressure taps Flange, Corner or D and D/2. Its loss is the permanent loss of the standard, worked out at the run; after a run the box Orifice plate - ISO 5167-2 gives beta, the discharge coefficient, the expansibility and the pressure loss. A flow meter is also where a controller of the Transient mode measures a flow.

A flow meter given as an orifice plate, after a run.
Figure 41 A flow meter given as an orifice plate, after a run.

6.7 Exchanger#

The Exchanger window, its Inputs page.
Figure 42 The Exchanger window, its Inputs page.

An Exchanger is a pressure drop element drawn as a heat exchanger, named E1, E2 and upward. Its Inputs page is that of a PD, with one field more; its Heat Transfer page says what it does to the temperature.

Table 23 The fields of an exchanger
FieldMeaning
Calculate K, Specify K, Fixed PD, PQ CurveThe pressure drop, as for a PD (section 6.6)
Required flowOptional. The flow the exchanger is designed for. The results then give its Overdesign: by how many per cent the flow it receives is over that need. A negative figure is an exchanger that is short
No heat transferThe liquid goes through at the temperature it came in with
Fixed dutyThe heat given to the liquid, in the power unit of the project: positive heats it, negative cools it
Outlet temperatureThe temperature the liquid leaves at; the duty is a result
The Heat Transfer page, here an outlet temperature.
Figure 43 The Heat Transfer page, here an outlet temperature.

The Heat Transfer page is used only when the fluid has Variable properties (section 5.4). With constant properties an exchanger is a pressure drop with a required flow.

6.8 Spray nozzle#

The Spray Nozzle window.
Figure 44 The Spray Nozzle window.
Table 24 The fields of a spray nozzle
FieldMeaning
Name, Nozzle onIts own name; No shuts the nozzle. A nozzle that is off has no overdesign
Select nozzleA nozzle of the library, with its K factor and minimum pressure; or User define
K FactorFlow = K √pressure, in the flow and pressure units of the project
Required flowThe flow the nozzle must give. The results give its Overdesign in per cent
Minimum PressureA warning is raised when the pressure at the nozzle is under it
Number of nozzlesSeveral equal nozzles at one point, entered as one

A nozzle discharges to the atmosphere. Where no pressure reaches it - it would draw water in - it is shut for the run and the run says it does not spray. Nozzle Layout on the Tools page lays out the nozzles of a whole tank or roof and inserts them with their pipework (section 10.3). With Hazen-Williams and Velocity pressure (NFPA 13, 15) ticked, a nozzle that passes flow on discharges by its normal pressure (section 5.3).

7 Running and reading results#

7.1 Missing inputs#

The status bar says Missing inputs - see why, in red, until every element has what it needs. Click the label: the window lists each element, under Element, with what it still lacks, under Missing input.

7.2 Running#

When the label reads Ready to run, in blue, press Run on the Home page. A model of a few hundred links is solved at once; a town network of 2 200 links takes about half a minute on an ordinary laptop.

After the run the label reads Solved, in green with the time of the run and how long it took, or Solved with warnings or with errors, in amber (chapter 12). A run can also leave a note: a part of the network left out because nothing reaches it, a control that could not be held. Any change of an input clears the results, and the label returns to Ready to run. While a run goes, Save is refused: the program says so.

7.3 Labels on the sheet#

The two Links selectors and the two Nodes selectors, above the sheet at the right, choose what is written beside every link and node: the name, an input, or a result such as flowrate, velocity, friction loss, pressure drop or pressure.

The Labels window, from the small square beside the selectors.
Figure 45 The Labels window, from the small square beside the selectors.
Table 25 The fields of the Labels window
FieldMeaning
Only pipesLabels on pipes only, not on pumps, valves and the rest
First variable, Second variable: DisplayShows or hides each of the two labels
Show unitWrites the unit after the value
LegendA key on the sheet naming the labels

Each label stands beside its element, clear of its symbol. The size of the labels is set on the Display page of Setting (section 5.3).

7.4 Colours#

On the Color Rule page of Setting choose the Variable of the pipes and of the nodes and tick Apply: the links and the nodes are coloured by that result in five bands, and a key on the sheet gives the ranges (section 5.3). Setting colors on the Home page only draws each kind in its own colour.

7.5 Results of one element#

The Properties page lists every input and result of the element selected. Show table on its menu puts the same on the sheet. The tables of chapter 8 give the results of every element of a kind at once. With Variable properties the page adds the temperatures, and for an exchanger its duty.

The Properties page of an exchanger with Variable properties.
Figure 46 The Properties page of an exchanger with Variable properties.

8 The Links and Nodes tables#

Links and Nodes on the Home page open a table with one row for each element.

The tables of pipes, of spray nozzles, of pressure drop elements and of exchangers can be typed in. The pencil opens the table: the cells that can be typed are in the colour of an input. Save checks the names and the numbers and writes the rows into the model; the results are cleared as after any change. A cell that is no number is left as it was, and Save says so.

Table 27 What can be typed
TableCells
PipesName, length, schedule and nominal size or inside diameter, material and roughness, fittings
Spray nozzlesName, nozzle type, K factor, required flow, minimum pressure, number, status
Pressure drop, ExchangerName and Mode always, and the Required flow of an exchanger; then what the mode of the row uses: Calculate K - reference flow, reference PD and power coefficient (K is worked out); Specify K - K and the power coefficient; Fixed PD - the pressure drop; PQ Curve - the curve stays in the window

8.3 The tables of pressure drop elements and exchangers#

Table 28 The columns of the Pressure drop and Exchanger tabs
ColumnMeaning
Name, Upstream node, Downstream nodeThe element and the nodes it joins
ModeCalculate K, Specify K, Fixed PD or PQ Curve; Orifice, for a flow meter only - the table refuses it for a plain pressure drop
Reference flow, Reference PDThe point K is worked out from, in the mode Calculate K
K value, Power coefficientDP = K (Flow)ⁿ
Flowrate, Pressure drop, Upstream pressure, Downstream pressureResults
Required flow, Overdesign (%)Exchanger tab only: the flow the exchanger needs, if given, and by how much the flow received is over it
Heat transfer, Inlet and Outlet temperature, DutyExchanger tab only: the model of its heat transfer and its value, and the results of a run with Variable properties

8.4 The Nodes table#

The Nodes table, with Find.
Figure 49 The Nodes table, with Find.

One row a node: its ID, name, elevation, pressure and flow in, and in the Transient mode the extremes of the run. Nodes the program makes for itself, such as the end node of a spray nozzle, are not listed, nor are ignored ones. The pencil opens the names and the elevations for typing, and Save writes them. Find and a click on a row work as in the Links table.

9 Scenario, Adjust and Calculator#

The Tools page: Database; Scenario, Adjust and Calculator; Pipe Sizing and Nozzle Layout.
Figure 50 The Tools page: Database; Scenario, Adjust and Calculator; Pipe Sizing and Nozzle Layout.

Base scenario Scenario, Adjust and Sizing change the model and work on the base case. If the Scenario Case selector of the Home page shows a case, set it back to Base Scenario first.

9.1 Scenario, type Sets#

The Scenario window, type Sets, with four cases run and one of them selected.
Figure 51 The Scenario window, type Sets, with four cases run and one of them selected.

A scenario runs the model for a list of cases and tabulates chosen results. Add scenario makes a page; Delete scenario removes it; a project can hold several. The type is chosen in Scenario type.

Table 29 A scenario of the type Sets
PartWhat it does
Select variableChooses the inputs that change from case to case: a demand, an elevation, a pipe size or state, a pump speed or state, a valve opening, a tank level, a property of the fluid, a group
Add variableChooses the results to tabulate: of a node, a link, or a formula of the Calculator
The tableThe cases down the side, the inputs and then the results across. The rows Object and Current value name each column and give the value the model has now
Add caseAdds a row that starts from the values the model has now. Type the value of each input in the blue cells
Duplicate, Remove caseAct on the row that is selected
The first columnType over case1 to give a case a name of its own
RunSolves every case and fills the results. A case that cannot be solved reads not solved, and the message says how many cases were solved
Results plotDraws the results against the cases
Enable case selectionKeeps each solved case, so that the Scenario Case selector of the Home page can show any of them on the sheet, in the tables and in the report
Apply to modelWrites the inputs of the selected case into the model, which then is that case. It asks first
Select variable: the kind, the element and its variable, moved into the list with >.
Figure 52 Select variable: the kind, the element and its variable, moved into the list with >.

The window of Select variable and Add variable lists the elements of the kind chosen in Object type, with a box to search by name; the variables of the element chosen show beside them; > and < move a variable into the list of the scenario and out of it; Select variables closes the window.

9.2 Scenario, type Sensitivity#

Scenario, type Sensitivity.
Figure 53 Scenario, type Sensitivity.

One input is varied from a Minimum to a Maximum by a Step size, and the results chosen with Add variable are tabulated at each step. Select variable chooses the input; Object names it. Run and Results plot work as in Sets.

9.3 Adjust#

The Adjust window.
Figure 54 The Adjust window.
Table 30 The fields of Adjust
FieldMeaning
Adjusted variableSelect variable: the input to vary, with an optional Minimum and Maximum
TargetSelect variable: the result to reach, and the Target value
Tolerance, Max. iterationsHow close the result must come, and how many runs are allowed
StartRuns the model again and again until the result is within the tolerance; the iterations are listed
Apply SolutionWrites the value found into the model
Auto AdjustMakes the search again at every run
Add Adjust, Delete AdjustA project can hold several, one a page

9.4 Calculator#

The Calculator.
Figure 55 The Calculator.

The Calculator keeps named formulas in the results of the model, and works them out again at every run.

Table 31 The parts of the Calculator
FieldMeaning
Add variableBrings in, as var1, var2..., a value of an element or of the fluid, or under General a figure of the whole network: the least and the greatest pressure of the nodes, flow of the pipes and velocity, the least overdesign of the nozzles
Formula: Name, the expression, AddA formula of the variables, with a name of its own
What a formula may hold+ - * / ^ and brackets; sqrt, sin, cos, tan, exp, abs; log, the natural logarithm, and log10; min, max and avg, the average, of a list such as max(var1, var2, var3)
?Opens a short guide to formulas
OutputEach formula and its value; Edit and Delete act on the one selected
Add Calculator, Delete CalculatorSeveral calculators, one a page

A formula can be shown in a table on the sheet, tabulated by a scenario and used as the target of Adjust.

10 Sizing, graphs, nozzles and the database#

10.1 Pipe sizing#

Pipe sizing, on its Set up page.
Figure 56 Pipe sizing, on its Set up page.
Table 32 The pages of Pipe sizing
PageWhat it holds
Set upSizing Method: Simple, Genetic Algorithm or Fire Water GA. With Simple: Check the sizes with a Run (ticked at first): the sizes are run on a copy, a pipe that fails goes one size up, up to five runs. Criteria set, with To all pipes, To the pipes selected and Criteria sets.... Pipes set: each pipe with its Phase, Criteria set and Limits now. Diameter set: the sizes allowed, with their cost. The genetic methods keep their Constraints
ResultsA line that sums the sizing up, the Total cost, and for each pipe its phase, size now and sized, inside diameter, velocity, friction loss a 100 length units, ρv², Set by and Meets; a figure past its limit in red. Generate report and Refresh at the foot
ParametersThe genetic methods only, greyed with Simple: Population size, Number of iterations, Mutation rate, and the penalties for a pressure or a velocity out of its limits
Autosize, ApplyRun the search, and write the sizes found into the model
Pipe sizing, its Results page.
Figure 57 Pipe sizing, its Results page.

A criteria set holds a row of limits for each phase - Liquid, Water, Gas, Multiphase: the most velocity, or k/ρⁿ, the least velocity, the most drop a 100 m, the most ρv² and the most Mach. Locked sets come from NORSOK P-001 and API RP 14E; a copy can be changed and kept in the project or in one's library. A pipe takes the row of its phase: in the Liquid mode Water when the fluid is water, else Liquid. A project sized with the old limits keeps them as Limits of this project.

Criteria sets: the limits of each phase.
Figure 58 Criteria sets: the limits of each phase.

10.2 Graphs#

Graphs is on the Home page.

A pump against its system.
Figure 59 A pump against its system.
The links of a path graph, in their order along the line.
Figure 60 The links of a path graph, in their order along the line.

10.3 Nozzle Layout#

Nozzle Layout for a cylindrical tank, after Auto layout.
Figure 61 Nozzle Layout for a cylindrical tank, after Auto layout.
Table 33 The fields of Nozzle Layout
FieldMeaning
Shape typeCylinder: the shell of a tank. Rectangle: a flat area, a roof or a deck
The tank, the surfaceIts size; Duty on the shell area or another surface; the Flow density to apply
The nozzleIts K value; for a cylinder the distance Header to ring; for a rectangle the spray angle and standoff
The rings, the gridHow many rings and nozzles a ring, or columns and rows; Auto layout finds them
Results, GeometryThe number of nozzles, the pressure at a nozzle, the flow of each and in all; the spacings and overlap
Design rulesThe limits the layout is checked against: pressures, distances between rings and between nozzles
Copy image, InsertA picture of the layout; Insert builds it on the sheet
Add Arrangement, Delete ArrangementSeveral layouts, one a page
Design rules: each limit with where it comes from.
Figure 62 Design rules: each limit with where it comes from.
Insert: the geometry proposed, and the preliminary sizing of the pipework.
Figure 63 Insert: the geometry proposed, and the preliminary sizing of the pipework.

Insert asks how to build the layout - for a rectangle a tree or a grid of pipes; whether to size the pipework as it is inserted, from which material and schedule and for which velocity - and a click on the sheet places the nozzles, the rings and the feed pipe as ordinary elements, with a supply node at the pressure the layout needs.

10.4 Database#

Database, its Fluid data page.
Figure 64 Database, its Fluid data page.
Table 34 The pages of Database
PageWhat it keeps
Fluid dataEach fluid with its density, viscosity and vapour pressure at several temperatures, and its Specific heat, one value
Piping materialEach material with its roughness, its C coefficient for Hazen-Williams, and its modulus of elasticity for the Transient mode
Piping scheduleEach schedule with its sizes: nominal, outside and inside diameter
FittingsEach fitting with its K factor
NozzlesEach spray nozzle with its K factor and its minimum pressure
Import db, Export dbRead or write the whole library as a file

Add, Edit and Delete under each list add an entry, change it or remove it. The libraries belong to the installation, so every project sees them.

The Specific heat under the table of the Fluid data page is the one value of the fluid selected. A value typed there is kept with the project and is taken by the Fluid window when that fluid is chosen.

The Fluid data page: the Specific heat of the fluid selected.
Figure 65 The Fluid data page: the Specific heat of the fluid selected.

11 Files and reports#

The Reports page: PDF Report, Datasheet and Excel; Screenshot; Project information.
Figure 66 The Reports page: PDF Report, Datasheet and Excel; Screenshot; Project information.

11.1 PDF Report#

Report generation.
Figure 67 Report generation.

PDF Report opens Report generation. The Project name, Project ref, Revision, Date, Prepared by and Company are those of Project information (section 11.3); changed here, they are kept with the project. Tick the sections - Fluid data, Nodes, Piping details, Pumps, Pumps Curves, Valves, General pressure drop, Tanks, Nozzle Spray, Piping Fittings, the NFPA 13 / 15 calculation with Hazen-Williams, and the Transient charts in the Transient mode. Tick Add under Notes to add the text typed below it. Generate report asks where to write the file.

The PDF has the FlowMax cover, a contents page, the basis of the calculation, a section for each part ticked with the inputs and results of every element, and the messages of the run; the company logo chosen in the Datasheets window stands on its cover and at the head of every page. When a case of a scenario is on show, the report is that of the case.

NFPA 13 / 15 calculation, offered with Hazen-Williams in steady state and ticked then, adds the hydraulic calculation in NFPA's form after the other sections: its basis - the Hazen-Williams formula of NFPA 13 and the method of the nozzles - the nozzles flowing with their K, total pressure Pt and flow, and with the velocity pressure of Setting, Advanced their Pv and normal pressure Pn; the pipes with their flow, bore, C, length, fittings as an equivalent length, friction a unit of length, friction loss Pf and pressure of elevation Pe.

11.2 Datasheet, Excel and Screenshot#

Table 35 The other commands of the Reports page
CommandWhat it does
DatasheetOpens the Datasheets window: the datasheets of the pumps, the control valves and the orifices
ExcelA workbook: Summary, Equipment list, Line list, a sheet for each kind as the tables show it, Equipment data and Notes. On the base case only
ScreenshotThe flowsheet in a drawing frame, as a PDF file
The Datasheets window: what each element holds and the cases of its sheet.
Figure 68 The Datasheets window: what each element holds and the cases of its sheet.

11.3 Project information#

Project information.
Figure 69 Project information.

Project information, the last command of the Reports page, holds the Project name, Project ref, Revision, Date, Prepared by and Company, and the company logo: the PDF report, the datasheets, the workbook and the screenshot carry them.

11.4 Project files and other programs#

12 Messages#

12.1 Warnings and errors of a run#

The list of a run: two pages, Errors and Warnings.
Figure 70 The list of a run: two pages, Errors and Warnings.

Click the label on the status bar after a run. The list has two pages, Errors and Warnings, each line with the name of the element; a click shows the element on the sheet.

Table 36 The messages of a run
MessageKindWhat it means
Pressure below the vapour pressure : the liquid may vaporizeErrorThe pressure at a node is under the vapour pressure of the fluid
Pressure drop across the pumpErrorThe pump is driven beyond the end of its curve and takes pressure instead of giving it
Pressure rise across the valve, Pressure rise across the pressure dropErrorThe flow goes backwards through the element
Inlet and outlet nodes are at different elevationsErrorThe two nodes of a pump, a valve or a fixed loss must stand at one elevation
Fitting type does not match the diameter changeErrorA reducer between two pipes of one size, or the reverse
NPSHa is low (less than 2 m), NPSHa is lower than NPSHrWarningThe suction of a pump is close to cavitation
Required valve opening is greater than 100 %WarningA control valve cannot reach its target
Overdesign is negative (less than the required flow)WarningA nozzle receives less than its required flow
Nozzle pressure is below its minimum pressureWarningA nozzle is under the least pressure it works at
The nozzle does not spray : no pressure reaches itWarningThe pressure at the nozzle is under the atmosphere; it is shut for the run
Flow is in the opposite directionWarningThe flow in a pipe goes against the way it was drawn. The result is right; the sign is negative

12.2 Notes of a run#

Table 37 What a run can tell besides the list
NoteWhat it means
Elements and nodes left with no route to a pressure boundaryWith Consider blocked links as ignored : a part cut off by shut elements is left out of the run
The spray system behind ... is dryA spray system reached only through something shut is left out of the run
... cannot hold its setting - it is left fully openA control valve asked for more than the line delivers
Missing inputsThe model is not complete: see the list (section 7.1)
Unknown bore of its orifice ; The bore of its orifice is not smaller than its pipe ; No pipe at its inlet or its outletA flow meter given as an orifice lacks what ISO 5167-2 needs: the run does not start until it has it (section 6.6)

If a model does not solve Look first for an edge with neither a pressure nor a flow, for a part of the network cut off from every pressure, and for two pressures fixed with nothing but a closed element between them.

12.3 Before a result is used#

Next: the Steady-State Training Manual works nine cases from an empty sheet to a report, and the Transient User Guide takes the same model into a transient.