Skip to the text
Flowmax · Transient

Quick Start

Transient ยท October 2026

This is the shortest way from an empty sheet to a result. It has no example in it: it says what is pressed, in what order, and what the program answers. The training manual of the mode works through complete systems and explains every window; come back to this page for the order of things.

1 The window#

The FlowMax window. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.
Figure 1 The FlowMax window. (1) the ribbon, (2) the Links and Nodes label selectors, (3) the Equipment strip, (4) the flowsheet, (5) the panel at the right, (6) the status bar, (7) the overview map.

A model is links joined at nodes. A link carries flow: a pipe, a pump, a valve, a fixed loss (PD), a tank, a nozzle. A node is where links meet and where a pressure is reported.

2 A transient in seven steps#

The Transient mode starts from the steady state of the same model and follows what happens when something changes: a valve moves, a pump stops. Build the model and solve its steady state first (the Liquid quick start).

The Transient page of the ribbon in the Transient mode: the switch, Save, Run, Integrator, Charts, Setting, Controller, Forces and Scenarios.
Figure 2 The Transient page of the ribbon in the Transient mode: the switch, Save, Run, Integrator, Charts, Setting, Controller, Forces and Scenarios.
  1. Switch to the Transient mode. On the Transient page move Transient Mode to on and confirm. A window lists what the mode needs of the model. The commands of the page then show, and all of them open one window, Transient, at one of its six tabs. A node of flow is enough for the run's edges: a pressure is no longer required.
  2. Give what a transient needs. Each property window now has a Transient page. A pipe: its outside diameter and material, from which its wave speed is worked out. A pump: its Modelling - Simple, Inertia or Four quadrant - with its moment of inertia and rated speed. A valve: its characteristic; a check valve is a valve with No reverse flow ticked. A tank: whether its level is held or varies in the run.
  3. Setting. Wave speed Calculated Per Pipe (or one value typed for all pipes), and the pipe restraint. Leave Cavitation model at None for a first run. Tick Enable Dry pipe selection only for pipes that start empty.
  4. Integrator (Figure 3). The initialisation time, the end time, the time step and the output step. The table at the right shows how each pipe is resolved at that step: its reaches and the error in its wave speed. Shorten the step, or declare a pipe short, until no pipe that matters shows a large error.
  5. Controllers. Nothing moves unless a controller moves it. Press Add controller, press Select OP and choose the opening of a valve, the speed of a pump, or a pump itself. Manual is a schedule, time against value; for a pump it is a list of Trip and Start events. Automatic holds a pressure, a flow or a level at its set point with a gain and an integral time.
  6. Charts. Press Add chart, then Set variables, and choose what to follow; Limit line draws a design pressure on the chart. Only what is asked for is kept as a history. Add transient chart, on the menu of an element, starts one from the sheet.
  7. Run, on the Transient page. Read the charts (Figure 4): the table under each gives the highest and lowest value of every series and when. On the sheet the label selectors now offer Max Pressure and Min Pressure, the envelope of the run. Read the message at the end of the run, if there is one.
Integrator: the times of the run at the left, how each pipe is resolved at the right.
Figure 3 Integrator: the times of the run at the left, how each pipe is resolved at the right.
Charts after a run, with a limit line; the table under the chart gives the maximum and minimum of each series.
Figure 4 Charts after a run, with a limit line; the table under the chart gives the maximum and minimum of each series.
Table 1 The other tabs and settings of the Transient window
WhereWhat it is for
ForcesThe unbalanced force on a straight run of pipe between two cuts, for the pipe supports: its maximum, its minimum and its history
ScenariosCases - the same model with a controller or a boundary changed - run one after the other, judged against limits and written into a report
Setting, Cavitation modelDVCM or DGCM, when a pressure of the first run reaches the vapour pressure: the liquid parts there, and the run without a model is no longer a result
Setting, Unsteady frictionDamps the later cycles of a wave as a real line does; the first peak does not change
Equipment stripSurge relief valve, air valve, accumulator and surge tank: the protection, drawn like any other element, enabled in the Transient mode

3 Before a result is used#