1 Introduction#
FlowMax calculates the flow and the pressure in a network of pipes that carries a liquid. In steady state it finds the flows and pressures that balance. In the Transient mode, the subject of this guide, it starts from that balance and follows what happens when something changes: a valve moves, a pump stops or starts, a line fills. It gives the pressure and the flow against time everywhere in the network, and the forces on the pipework.
This guide is a reference. It goes through the Transient mode and every tab of its window, what each piece of equipment needs in a transient, the protection equipment, the controllers, the results and the scenarios, and says what each field means and what each command does. It works no example: the Transient Training Manual does that, with ten complete cases and their project files. Drawing a model and solving its steady state are in the Liquid User Guide.
The pictures are the windows of the program itself. A red numbered circle on some of them marks a field the training manual speaks of; here it can be passed over.
| Subject | What FlowMax offers |
|---|---|
| Events | Valve opening and closure on a schedule; pump trip, start and speed change; several events in one run |
| Pumps | Run-down and start with the inertia of the set and the torque curve of the motor; four quadrant behaviour with reverse flow and reverse rotation |
| Valves | Control valves with their characteristic; non-return valves, simple or with the inertia of the disc; automatic control of a pressure, a flow or a level |
| Liquid column | Vapour cavities and their collapse (DVCM, DGCM); unsteady friction; pipes that start empty and fill |
| Protection | Surge relief valve, air valve, accumulator, surge tank, drawn like any other element |
| Results | Charts of any result against time; the highest and lowest pressure of every pipe and node; forces on pipe runs for the stress analysis |
| Studies | Scenarios: cases run one after the other, judged against limits and written into a report |
2 Installation and licence#
2.1 System requirements#
| Item | Requirement |
|---|---|
| Operating system | Windows 10 or Windows 11, 64-bit |
| Processor | Dual core, 1.8 GHz or faster |
| Memory | 4 GB; 8 GB recommended, and for long transients of large models |
| Disk | 1 GB free |
| Screen | 1280 x 768 or larger |
| Internet | Needed to activate the licence, unless an offline file is used |
2.2 Installing#
- Start the Flowmax Setup application.
- Read the information of the first page and press Next if you agree.
- Choose whether a shortcut is put on the desktop.
- Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.
2.3 Activating the licence#
The first time FlowMax starts it shows the licence window.
- Activate License asks for the licence key that came with the purchase.
- Without internet, Offline license file writes a request to send to support, and Activate License reads the file that comes back.
FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.
What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.
2.4 Help and examples#
The File menu holds them, for the mode the project is in:
- Help File opens the user guide of the mode, Training Manual its training manual: from the folder docs beside the program, or, when they are not installed, from the tutorials page of processtool.net.
- Show Example opens the example projects of the mode, in the folder examples beside the program. The start window lists them all under Examples.
- About Flowmax gives the version and the licence.
The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.
3 The Transient mode#
3.1 The Transient page and the switch#

| Command | What it does |
|---|---|
| Transient Mode | The switch between the steady state and the Transient mode |
| Run | Runs the transient (section 3.3) |
| Integrator | Opens the Transient window at its Integrator tab |
| Real Time | Slows the run down to the clock: each time step takes at least its own length. To watch a run as it happens |
| Charts, Setting, Controller, Forces, Scenarios | Open the Transient window at that tab: chapter 4 |
Build the model and solve its steady state first. Then move Transient Mode to on and confirm. A window lists what the mode needs of the model. The commands of the page then show. A project remembers its mode and opens in it; move the switch back to return to the steady state. Save, Undo and Redo are in the title bar. The Transient mode needs a Liquid Transient or a Complete licence.
3.2 What changes in the Transient mode#
- Everything is switched on when the mode is entered. In a transient the state of an element is its opening or its speed, not on or off. The window names every valve, pump and pipe that is switched off: set them on, and enter a shut valve at 0 % opening. A spray nozzle may stay off: it has not operated.
- Pumps and valves are on their curve or at an opening. A pump needs its curve and a valve its Cv. One given a flow, a pressure, a head or a drop in steady state (Flow set, Pressure set, Head set, Drop set) is put back on Rating by Make changes in the window of the switch; in the Transient mode its Specification is greyed.
- A fixed pressure drop and an inline pressure drop are not supported.
- The steady-state tools are greyed: Calculator, Scenario, Adjust and Sizing, the Run of the Home page and the Scenario Case selector. The Run to use is the one of the Transient page.
- The windows of the elements gain a page: Transient for a pipe, a tank and a pump, Inertia for a non-return valve; chapter 5.
- The Fluid window shows the Bulk modulus of the liquid (section 5.1).
- The liquid has constant properties. A fluid of Variable properties is set to Constant properties, at the temperature of the Fluid window, when the mode is entered, and a message says so (section 5.1).
- The status of a pipe Closed is not available: a closed pipe has to stay in the network to reflect the wave. Use a valve at 0 %.
- The protection comes alive on the Equipment strip: the surge relief valve, air valve, accumulator, surge tank and controller, greyed in steady state, can be placed.
- A node of flow is enough at an edge: a pressure is no longer required; the list says No pressure or flow specification in the model when there is neither.
- Velocity pressure (NFPA 13, 15) of the Setting is not used in a transient.

3.3 What a run does#
Run on the Transient page does three things in order. It solves the steady state of the model as it stands. It lets that state settle for the initialisation time with nothing moving. Then it runs to the end time, moving whatever the controllers move, and keeps a point of every chart at each output time step. While it runs the status bar counts the time.
When the run is over the charts are drawn, every pipe and node carries the highest and lowest pressure it saw, and a message says, once, whatever needs saying: a time step too coarse for a pipe, a force that could not be calculated, a tank that overflowed.
Before a run If the status bar reads Missing inputs, click it. In the Transient mode the list includes the wave speed of every pipe and the inertia and rated speed of a pump that is modelled with its inertia.
3.4 The order of work#
- Solve the steady state and switch to the Transient mode.
- Give each element what a transient needs, on the Transient page of its window: chapter 5. Add the protection: chapter 6.
- Setting: how the wave speed is found; the cavitation model; dry pipes.
- Integrator: the times of the run and the time step.
- Controllers: what moves, and when: chapter 7.
- Charts: what to follow. Forces: the runs of pipe whose force is wanted.
- Run, and read the charts, the sheet, the tables and the message of the run: chapter 8.
- For several cases, Scenarios: chapter 9.
4 The Transient window#
Every command of the Transient page opens the same window at one of its six tabs. A tab that holds several things - charts, controllers, forces, scenario pages - has their list down its left side and its buttons at the top right.
4.1 Setting#

| Field | Meaning |
|---|---|
| Wave Speed: Calculated Per Pipe | The speed of a pressure wave in each pipe is worked out from the fluid, the size, the wall and the material of that pipe |
| Wave Speed: User Input | One speed typed for the whole model; Apply to all pipes writes it into every pipe |
| Pipe restraint | How the pipes are held, which enters the calculated speed: Anchored upstream end only, Anchored against axial movement, or With expansion joints |
| Cavitation model: None | The liquid is taken as never parting. Right as long as no pressure of the run reaches the vapour pressure |
| Cavitation model: DVCM, DGCM | Where the pressure reaches the vapour pressure a cavity opens, grows and closes again. DVCM is the discrete vapour cavity model; DGCM, the discrete gas cavity model, adds a small amount of free gas. Run both and compare |
| Enable Dry pipe selection | Lets a pipe be declared dry: empty at the start and filling in the run (section 5.2) |
| Air expansion model | Shown with dry pipes: how the air ahead of the water is compressed, Isothermal or Adiabatic |
| Unsteady friction | Adds the friction of a changing flow. The first peak does not change; the cycles after it die away as in a real line |
4.2 Integrator#

| Field | Meaning |
|---|---|
| Initialization (s) | Seconds run with nothing moving before the transient starts |
| End time (s) | The length of the transient |
| Calculated Time Step | The step the program proposes from the pipes of the model |
| Specify Timestep | A step typed instead |
| Output time step (s) | How often a point of each chart is kept. A run cannot report more often than it computes |
| Pipe resolution | For each pipe at this time step: its length, its wave speed, the number of Reaches it is cut into and the Error this makes in its wave speed; the worst pipe is named above the table |
| Make short pipe, Make normal | Act on the pipes ticked in the table: a short pipe is taken as a loss with no wave in it, and no longer limits the step |
| Use this time step | Takes the step the text above the buttons proposes |
A pipe is cut into reaches that a wave crosses in one time step. A pipe much shorter than the others forces a small step, or is resolved badly. Tick a pipe to read what declaring it short would allow. Shorten the step until no pipe that matters shows a large error, or make a very short pipe a short pipe. The same status, Short pipe, is on the Inputs page of the Pipe window.
4.3 Charts#

| Command | What it does |
|---|---|
| Add chart, Remove | Make a chart or remove the one selected in the list at the left |
| Name | The title of the chart |
| Set variables | Chooses what the chart follows: the window lists the elements of the Object type chosen, their variables under Parameter, and > and < move them onto the chart. Add constant puts a constant value on it |
| Remove variable | Takes the selected series off the chart |
| Limit line | Draws a constant across the chart: an allowable pressure, a design flow |
| On this chart | One row a series: a tick to show or hide it, the element, the variable, and its Max and Min with the time at s of each |
| Copy picture, View data | The chart as a picture for a report; its points as a table for a spreadsheet |
| Open in window | The chart large, in a window of its own |
- A chart can follow the pressure of a node, the flow and pressures of a pipe, the speed of a pump, the opening of a valve, the level of a tank, the gas volume of an accumulator, the air flow of an air valve, a force and more.
- A chart can also be started from the sheet: right-click an element and choose Add transient chart.
- Only what is on a chart before the run is kept as a history. The highest and lowest pressure of every node and pipe are kept whatever the charts (section 8.1).
4.4 Controllers, Forces and Scenarios#
The Controllers tab holds what moves during the run: chapter 7. The Forces tab holds the forces on runs of pipe: section 8.4. The Scenarios tab runs cases one after the other: chapter 9.
5 Fluid and equipment in the Transient mode#
In the Transient mode the window of an element has a further page beside its Inputs page. This chapter gives what that page holds. The fields of the Inputs page are in the Liquid User Guide.
5.1 Fluid#

The Bulk modulus is the stiffness of the liquid. With the wall of each pipe it gives the speed of a pressure wave. A fluid of the library comes with its value; with Direct properties it is typed with the others.
The Transient mode works with Constant properties only. A model whose fluid has Variable properties in the steady state is set to Constant properties when the Transient mode is entered: the temperature of the Fluid window is kept, the density and the viscosity are those of that temperature, and a message says so. In the Transient mode the Fluid window does not offer Variable properties, and a project saved so opens with constant properties.
5.2 Pipe#

| Field | Meaning |
|---|---|
| Outside diameter, Modulus of elasticity, Poisson's ratio | The wall of the pipe. With the bulk modulus of the fluid and the pipe restraint they give the wave speed |
| Wave speed | Calculated, or typed when the Setting tab is on User Input |
| Pipe content | Wet (full of liquid), or Dry (fills with time). Offered when dry pipes are enabled on the Setting tab |
| Status: Short pipe | On the Inputs page. The pipe is taken as a loss with no wave in it |
A dry pipe starts empty. Water enters it when the element upstream opens; the air ahead of the water leaves through whatever is open at the far end - a nozzle, an air valve, an open end - and is compressed if nothing is. A dry pipe is drawn hollow on the sheet. In the steady state a spray system behind a shut valve is left out of the run as dry; the Transient mode fills it.
5.3 Tank#

| Field | Meaning |
|---|---|
| Geometry | Vertical: a cylinder standing on its base |
| Diameter, Tank height | The size of the tank |
| Initial Liquid level | The level at the start of the run |
| Level in the run: Constant | The tank is large: its level does not move during the transient |
| Level in the run: Varies | The level follows the flow in and out. A note is given after the run if the tank overflows or empties |
| Top inlet node | The node, of given pressure, where a line that fills the tank from above ends. None when there is no such line |
5.4 Pump#

| Field | Meaning |
|---|---|
| Pump modelling: Simple | The pump follows its curve at the speed a controller gives it. A trip is a speed that falls on a schedule |
| Pump modelling: Inertia | The speed after a trip comes from the Total inertia of pump, motor and liquid and the Rated speed. The power curve of the pump must be filled on the Inputs page |
| Pump modelling: Four quadrant | As Inertia, with the complete characteristic: reverse flow, reverse rotation, the pump as a turbine. Suter data (4Q) opens its table |
| T-S curve (start-up) | The torque of the motor against its speed. Enter data opens its table. A start then follows the motor, not a ramp |

Auto fill fills the table with the curve of a general-purpose induction motor, scaled to the values typed; Generate draws it. Replace it with the curve of the motor when it is known.

The table holds the dimensionless head WH and torque WB against the angle Theta. It comes filled with a generic radial pump: replace it with the data of the maker. Reset to generic fills it again; Generate draws it. Radial pump (nq 25) fills the table with the published curve of a radial pump of specific speed 25. Rated flow and Rated torque give the rated point; left empty they come from the steady state, the torque at 75 % efficiency.

A pump is tripped and started by a controller on the pump itself (section 7.3). A pump that stands by at the start of the run is entered with Relative speed 0; Pump on then reads No, and in the Transient mode it follows the speed. A pump that is stopped and has no non-return valve is an open path: flow can pass through it either way.
5.5 Valve#

A valve needs its Cv or Kv at full opening and its Valve type, the law between opening and capacity: Linear, Eq Percentage, Quick Opening, or a Valve curve of points. Its Opening (%) is the opening at the start of the run; a controller moves it. A shut valve is entered at 0 %.
5.6 Non-return valve#

Non Return Valve on the Equipment strip places a valve that shuts when the flow would turn back. In the Transient mode its window has an Inertia page.
| Field | Meaning |
|---|---|
| Modelling: Simple | The valve shuts at the instant the flow turns back |
| Modelling: Inertia | The disc moves under the flow, its weight and its spring: it shuts late, with a reverse flow already running, and that is what makes a check valve slam |
| Valve type | Swing check, Tilting disc, Dual plate or Nozzle |
| Valve bore | Defaulted from the pipe the valve stands in |
| Disc inertia, Spring constant, Torque coefficient, Damping, Closing preload | The data of the disc. They are estimated from the bore and the type: replace them with the figures of the datasheet when there are some |
5.7 Pressure drop, exchanger, flow meter and nozzle#
- A general pressure drop follows DP = K (Flow)ⁿ in the transient as in the steady state. The Fixed PD mode is not supported in the Transient mode.
- An exchanger is a pressure drop element in the transient, as a PD. Its Heat Transfer page is not used, since the liquid has constant properties.
- A flow meter is a pressure drop element drawn as a meter. It is where a controller measures a flow. With the model Orifice it keeps the K that ISO 5167-2 gives it at the start of the run.
- A spray nozzle discharges to the atmosphere through its K factor. On a dry pipe an open nozzle is also where the air leaves.
6 Surge protection equipment#
The four kinds of protection are on the Equipment strip and are drawn like any other element. Each has one connection to the line, except the surge relief valve, which has an inlet and an outlet. A piece of protection can be ignored from the menu of the right mouse button and made active again, so that a run with it and a run without it are made on one model. Their names start with SRV, ARV, ACM and SRG-T, as set on the Naming tab of Setting.
6.1 Surge relief valve#

| Field | Meaning |
|---|---|
| Set Pressure | The pressure at which the valve starts to open |
| Full Open Pressure | The pressure at which it is wide open |
| Area, Cd Factor | The flow area at full lift and its discharge coefficient |
| Type: Proportional | The lift follows the pressure between the two values |
| Type: Proportional with reseat | As Proportional, but the valve shuts again only when the pressure has fallen by the Blowdown, in per cent |
| Type: Pop safety valve | Opens fully at the set pressure and shuts again after the blowdown |
| Type: Bursting disc | The fields become Burst Pressure and Rupture time. The disc opens once and stays open |
| Time constant | How fast the valve moves, in seconds |

The outlet Give the outlet node of a relief valve a pressure, 0 for the atmosphere, or draw the line it discharges into.
6.2 Air valve#

An air valve lets air into the line when the pressure falls under its set pressure and lets it out again when the liquid returns. It has one connection and always opens to the atmosphere. Inlet Valve Flow and Outlet Valve Flow each have their Set Pressure, Diameter and Cd Factor: a large inlet breaks a vacuum; a small outlet holds the air back as a cushion, so that the returning column is slowed instead of striking.
6.3 Accumulator#

An accumulator is a closed vessel with gas over the liquid. It feeds the line when the pressure falls and takes liquid back when it rises. Its Inputs page has its name and its Tank elevation. Its Transient page has the Geometry, the Diameter and Length, the Initial Liquid level, the Initial Pressure and Initial Temperature of the gas and the ratio Gas Cp/Cv, which sets how the gas answers when it is compressed.
6.4 Surge tank#

A surge tank is an open tank standing on the line, usually at a high point. Its level moves with the pressure of the line. It needs its Tank elevation on the Inputs page and its Geometry, Diameter, Initial Liquid level and Tank height on the Transient page; a note is given after the run if it overflowed or ran empty.
7 Controllers#
Nothing moves in a run unless a controller moves it. Press Add controller on the Controllers tab, then Select OP under Target Output and choose what the controller acts on: the opening of a valve, the relative speed of a pump, or a pump itself. Remove deletes the controller selected in the list at the left.
| Mode | What the controller does |
|---|---|
| Manual | Follows a schedule of output against time (section 7.1), or a list of trips and starts for a pump (section 7.3) |
| Automatic | Holds a measured value at its set point (section 7.2) |
| Off | Does nothing. The controller is kept, to be switched on again, and a scenario can switch it case by case |
The Controller square of the Equipment strip places a controller on the sheet; its lines show what it measures and what it moves. A controller in a loop is lettered by what it measures: PC for a pressure, FC for a flow, LC for a level.
7.1 Manual: a schedule#

| Field | Meaning |
|---|---|
| Function type: Constant | The output keeps the Output value typed for the whole run |
| Function type: Linear | A table of Time (s) against Output. Between two rows the output moves in a straight line. The times must rise from row to row |
| The plot | Shows the schedule as typed |
An opening is in per cent; a speed is relative to the speed of the pump curve. A closure in 0.1 s is written as two rows 0.1 s apart.
7.2 Automatic: a control loop#

| Field | Meaning |
|---|---|
| Select PV | What is measured: the pressure of a node, the flow of a flow meter or a pressure drop element, the level of a tank |
| Set Point | The value to hold, in the unit of what is measured |
| Gain (Kc), Integral time (Ti), Derivative time (Td) | The three terms of the controller. The times are in minutes |
| Action | Direct: the output rises when the measurement rises. Reverse: it falls |
| OP min (%), OP max (%) | The limits of the output |
| Start from steady state | The output starts at the value the steady state has, so that the run begins in balance |
| Hold that opening - no regulation | The output stays at that value for the whole run |
With a controller in Automatic, Control links on the Home page draws a dotted line from each controller to the point it measures.
7.3 A pump: trip and start#
Select OP on a pump offers two outputs: its Relative speed, which a schedule or a loop moves, and Trip / Start. With Trip / Start the table of the Manual mode is a list of events: at each time, Trip or Start. Modelled with its inertia (section 5.4), a tripped pump runs down by that inertia and a started pump follows the torque curve of its motor. Several events can follow one another in a run, a trip and a restart for example.
8 Results#
8.1 On the sheet and in the tables#
- The label selectors offer, in the Transient mode, Max Pressure and Min Pressure for nodes and pipes, Max Flow and Min Flow for pipes, and Max Cavitation and Min Cavitation with a cavitation model: the envelope of the run.
- The Links and Nodes tables of the Home page have the same columns. The time at which each extreme was reached is read on a chart.
- The Color Rule of Setting colours the sheet by any of these, so that the highest pressures of a run are seen at a glance.
- A force can be shown as a label too: Max Force, Min Force, Calculated force.
8.2 Charts#
The charts of section 4.3 are drawn when the run ends. Read under each one the highest and lowest value of every series and its time, and compare them with the limit line. Open in window shows a chart large; its menu of the right mouse button offers View data, Edit chart title, Edit label, Print and Copy as image.
8.3 The report#
PDF Report on the Reports page writes the PDF described in the Liquid User Guide. In the Transient mode, once the Charts tab holds a chart, its window frees the tick Transient charts, which adds one page for every chart. The report of a set of cases is made from the Scenarios tab (section 9.4).
8.4 Forces#

A pressure wave that passes through a run of pipe pushes on it, because the pressure at its two ends differs for a moment. The Forces tab gives that unbalanced force for the pipe supports and the stress analysis.
| Field | Meaning |
|---|---|
| Add force, Duplicate, Remove | Make a force, copy the one selected, delete it. All forces in the list shows them together |
| Name | The name of the force |
| Control volume: Cut 1, Cut 2 | The run of pipe between two cuts. Each cut is a pipe, a place along it - its start, its end or a distance typed - and its kind |
| Rigid, Elastic | Rigid: the piping carries on at the cut - more pipe, an elbow, a tee, a dead end - and nothing is counted there. Elastic: the piping cannot pass a force across - an anchor, an expansion joint, a hose, an open end - and the pressure and momentum at the cut are counted |
| Axial force | The force along a straight run. Positive acts from cut 1 towards cut 2 |
| All axes | The force as a vector, for a run that turns. Each cut then needs the direction that points out of the volume |
| Results | The Maximum and the Minimum of the run with their times, and the Steady force before the transient |
| Force over time | The force against time; Add to chart puts it on a chart of the Charts tab |
| Write time history for stress analysis | Writes the force against time as an Excel and a CSV file beside the project |
The sketch at the top right shows the control volume, its two cuts and the direction of a positive force.
8.5 The message of a run#
A run that has something to say says it once, when it ends. Read it before using a number.
| Subject | What to do |
|---|---|
| The time step is too large for a pipe: its wave speed is distorted | Shorten the step on the Integrator tab, or declare the pipe short |
| A tank or a surge tank that overflowed or ran empty | Check its size and its initial level |
| A force that was not calculated | The message names the force. Check its two cuts |
| Solved with errors or warnings | Click the mark on the status bar for the list, as in the steady state |
9 Scenarios#
A scenario of the Transient mode is a list of cases. Each case is the same model with something changed - a controller, a boundary - and all of them are run one after the other and compared. The tab has four pages, chosen at its left, and three buttons at the top right. The line at the top counts the cases, the results watched and those over their limit.
| Command | What it does |
|---|---|
| Run all | Runs every case ticked in the Run column |
| Run selected | Runs the case selected |
| Report | Writes the report of section 9.4. While the cases run, the same button reads Stop |
9.1 Cases#

| Command | What it does |
|---|---|
| The table | Cases down the side, what they vary across the top: the mode or the schedule of a controller, the pressure of a node, a value of an element. A cell left empty reads as drawn: that case takes the value of the model |
| Run, Case | The tick that puts the case in Run all; its name |
| Add case, Duplicate, Remove case | Add a case, copy the one selected, delete it |
| Add variable, Remove variable | Add a column: what a case can change. Remove the column selected |
| Edit cell, Clear cell | Set the cell selected; empty it so that the case takes the value of the model |
| A controller cell | Holds a mode: Off, a set point, or a schedule shown as what it does - closing or opening, and over how long. Double-click it to set it; type a value into the other cells |
| Apply to model | Loads the differences of the selected case into the model, which then is that case: the Run of the Transient page runs it and the report reports it as any model |
An element can be added to the cases from the sheet: right-click it and choose Add to scenario.
9.2 Outputs#

Add result adds a row: an element, a variable - the same quantities the charts offer - and where along a pipe under At. Max limit and Min limit are judged the right way round: a maximum has to stay below its limit, a minimum above. Chart draws the result for every case on the Charts page. Remove deletes the row selected.
9.3 Charts#

Each result ticked under Chart is drawn for every case run, with its limits as dashed lines. Every case on the same axes is best for comparing a handful; tick one chart per case to draw each case on its own.
9.4 Summary & Report#

The Summary gives the watched results, one row per case: the highest and the lowest value, in red where a limit is passed. It fills when the cases are run.
| Tick | What it adds |
|---|---|
| Case list and their differences | The table of the Cases page |
| Summary table | The summary above |
| Charts | The charts of the Charts page; One chart per case, four to a page when ticked, otherwise every case on one chart |
| Exceedances, called out | Every limit passed, named on its own |
| Force time histories | The forces against time; Write the force time histories into the same folder writes them as files beside the report |
These parts are added to the PDF the program already prints, so the description of the network comes with them. The model itself is not changed by a run of the scenarios.
10 Before a result is used#
- The steady state the run starts from is solved with no error.
- The lowest pressure of the run is above the vapour pressure. If it is not, a cavitation model is on, and DVCM and DGCM have been compared.
- The Integrator shows no pipe that matters with a large error. A run at half the time step moves the peaks little.
- A pressure made by a cavity or an air pocket that closes is an order of magnitude, not a figure to three places.
- A pump that stands by is entered at relative speed 0; a valve that is shut is entered at 0 %.
- A relief valve relieves to a pressure: its outlet node has one.
- The data of a check valve disc, of a motor torque curve and of a four quadrant pump are those of the maker, not the estimates the windows start from.
Next: the Transient Training Manual works ten cases, from a reservoir, a pipe and a valve to a fire water system that fills, each with its project files.