1 Introduction#

FlowMax calculates the flow and the pressure in a network of pipes that carries a liquid. In steady state it finds the flows and pressures that balance. In the Transient mode, the subject of this guide, it starts from that balance and follows what happens when something changes: a valve moves, a pump stops or starts, a line fills. It gives the pressure and the flow against time everywhere in the network, and the forces on the pipework.

This guide is a reference. It goes through the Transient mode and every tab of its window, what each piece of equipment needs in a transient, the protection equipment, the controllers, the results and the scenarios, and says what each field means and what each command does. It works no example: the Transient Training Manual does that, with ten complete cases and their project files. Drawing a model and solving its steady state are in the Liquid User Guide.

The pictures are the windows of the program itself. A red numbered circle on some of them marks a field the training manual speaks of; here it can be passed over.

Table 1 What the Transient mode does
SubjectWhat FlowMax offers
EventsValve opening and closure on a schedule; pump trip, start and speed change; several events in one run
PumpsRun-down and start with the inertia of the set and the torque curve of the motor; four quadrant behaviour with reverse flow and reverse rotation
ValvesControl valves with their characteristic; non-return valves, simple or with the inertia of the disc; automatic control of a pressure, a flow or a level
Liquid columnVapour cavities and their collapse (DVCM, DGCM); unsteady friction; pipes that start empty and fill
ProtectionSurge relief valve, air valve, accumulator, surge tank, drawn like any other element
ResultsCharts of any result against time; the highest and lowest pressure of every pipe and node; forces on pipe runs for the stress analysis
StudiesScenarios: cases run one after the other, judged against limits and written into a report

2 Installation and licence#

2.1 System requirements#

Table 2 What FlowMax needs
ItemRequirement
Operating systemWindows 10 or Windows 11, 64-bit
ProcessorDual core, 1.8 GHz or faster
Memory4 GB; 8 GB recommended, and for long transients of large models
Disk1 GB free
Screen1280 x 768 or larger
InternetNeeded to activate the licence, unless an offline file is used

2.2 Installing#

  1. Start the Flowmax Setup application.
  2. Read the information of the first page and press Next if you agree.
  3. Choose whether a shortcut is put on the desktop.
  4. Wait for the installation to end, then open FlowMax from the shortcut or from Flowmax.exe in the folder it was installed in.

2.3 Activating the licence#

The first time FlowMax starts it shows the licence window.

FlowMax opens only with a licence. Without one, or with one that has expired, the licence window stays, and closing it closes FlowMax. A licence that runs for two months or less is a trial: the title of the window says so, with the days left, and so does About Flowmax.

What a licence allows is set by its edition. Liquid Lite holds up to 40 links in one model; Liquid, Liquid Transient, Liquid Gas and Complete up to 4 999. The Transient mode needs Liquid Transient or Complete, the Gas & Multiphase mode Liquid Gas or Complete; with another licence the program says the feature is not available.

2.4 Help and examples#

The File menu holds them, for the mode the project is in:

The three training manuals - Steady-State, Transient and Gas - work complete cases step by step, each with its project files.

3 The Transient mode#

3.1 The Transient page and the switch#

The Transient page of the ribbon in the Transient mode.
Figure 1 The Transient page of the ribbon in the Transient mode.
Table 3 The Transient page
CommandWhat it does
Transient ModeThe switch between the steady state and the Transient mode
RunRuns the transient (section 3.3)
IntegratorOpens the Transient window at its Integrator tab
Real TimeSlows the run down to the clock: each time step takes at least its own length. To watch a run as it happens
Charts, Setting, Controller, Forces, ScenariosOpen the Transient window at that tab: chapter 4

Build the model and solve its steady state first. Then move Transient Mode to on and confirm. A window lists what the mode needs of the model. The commands of the page then show. A project remembers its mode and opens in it; move the switch back to return to the steady state. Save, Undo and Redo are in the title bar. The Transient mode needs a Liquid Transient or a Complete licence.

3.2 What changes in the Transient mode#

The Equipment strip in the Transient mode: the protection and the controller, its third group, are no longer greyed.
Figure 2 The Equipment strip in the Transient mode: the protection and the controller, its third group, are no longer greyed.

3.3 What a run does#

Run on the Transient page does three things in order. It solves the steady state of the model as it stands. It lets that state settle for the initialisation time with nothing moving. Then it runs to the end time, moving whatever the controllers move, and keeps a point of every chart at each output time step. While it runs the status bar counts the time.

When the run is over the charts are drawn, every pipe and node carries the highest and lowest pressure it saw, and a message says, once, whatever needs saying: a time step too coarse for a pipe, a force that could not be calculated, a tank that overflowed.

Before a run If the status bar reads Missing inputs, click it. In the Transient mode the list includes the wave speed of every pipe and the inertia and rated speed of a pump that is modelled with its inertia.

3.4 The order of work#

  1. Solve the steady state and switch to the Transient mode.
  2. Give each element what a transient needs, on the Transient page of its window: chapter 5. Add the protection: chapter 6.
  3. Setting: how the wave speed is found; the cavitation model; dry pipes.
  4. Integrator: the times of the run and the time step.
  5. Controllers: what moves, and when: chapter 7.
  6. Charts: what to follow. Forces: the runs of pipe whose force is wanted.
  7. Run, and read the charts, the sheet, the tables and the message of the run: chapter 8.
  8. For several cases, Scenarios: chapter 9.

4 The Transient window#

Every command of the Transient page opens the same window at one of its six tabs. A tab that holds several things - charts, controllers, forces, scenario pages - has their list down its left side and its buttons at the top right.

4.1 Setting#

The Setting tab, with dry pipes enabled.
Figure 3 The Setting tab, with dry pipes enabled.
Table 4 The Setting tab
FieldMeaning
Wave Speed: Calculated Per PipeThe speed of a pressure wave in each pipe is worked out from the fluid, the size, the wall and the material of that pipe
Wave Speed: User InputOne speed typed for the whole model; Apply to all pipes writes it into every pipe
Pipe restraintHow the pipes are held, which enters the calculated speed: Anchored upstream end only, Anchored against axial movement, or With expansion joints
Cavitation model: NoneThe liquid is taken as never parting. Right as long as no pressure of the run reaches the vapour pressure
Cavitation model: DVCM, DGCMWhere the pressure reaches the vapour pressure a cavity opens, grows and closes again. DVCM is the discrete vapour cavity model; DGCM, the discrete gas cavity model, adds a small amount of free gas. Run both and compare
Enable Dry pipe selectionLets a pipe be declared dry: empty at the start and filling in the run (section 5.2)
Air expansion modelShown with dry pipes: how the air ahead of the water is compressed, Isothermal or Adiabatic
Unsteady frictionAdds the friction of a changing flow. The first peak does not change; the cycles after it die away as in a real line

4.2 Integrator#

The Integrator tab: the times of the run at the left, how each pipe is resolved at the right.
Figure 4 The Integrator tab: the times of the run at the left, how each pipe is resolved at the right.
Table 5 The Integrator tab
FieldMeaning
Initialization (s)Seconds run with nothing moving before the transient starts
End time (s)The length of the transient
Calculated Time StepThe step the program proposes from the pipes of the model
Specify TimestepA step typed instead
Output time step (s)How often a point of each chart is kept. A run cannot report more often than it computes
Pipe resolutionFor each pipe at this time step: its length, its wave speed, the number of Reaches it is cut into and the Error this makes in its wave speed; the worst pipe is named above the table
Make short pipe, Make normalAct on the pipes ticked in the table: a short pipe is taken as a loss with no wave in it, and no longer limits the step
Use this time stepTakes the step the text above the buttons proposes

A pipe is cut into reaches that a wave crosses in one time step. A pipe much shorter than the others forces a small step, or is resolved badly. Tick a pipe to read what declaring it short would allow. Shorten the step until no pipe that matters shows a large error, or make a very short pipe a short pipe. The same status, Short pipe, is on the Inputs page of the Pipe window.

4.3 Charts#

The Charts tab after a run, with a limit line and the table of the highest and lowest values.
Figure 5 The Charts tab after a run, with a limit line and the table of the highest and lowest values.
Table 6 The Charts tab
CommandWhat it does
Add chart, RemoveMake a chart or remove the one selected in the list at the left
NameThe title of the chart
Set variablesChooses what the chart follows: the window lists the elements of the Object type chosen, their variables under Parameter, and > and < move them onto the chart. Add constant puts a constant value on it
Remove variableTakes the selected series off the chart
Limit lineDraws a constant across the chart: an allowable pressure, a design flow
On this chartOne row a series: a tick to show or hide it, the element, the variable, and its Max and Min with the time at s of each
Copy picture, View dataThe chart as a picture for a report; its points as a table for a spreadsheet
Open in windowThe chart large, in a window of its own

4.4 Controllers, Forces and Scenarios#

The Controllers tab holds what moves during the run: chapter 7. The Forces tab holds the forces on runs of pipe: section 8.4. The Scenarios tab runs cases one after the other: chapter 9.

5 Fluid and equipment in the Transient mode#

In the Transient mode the window of an element has a further page beside its Inputs page. This chapter gives what that page holds. The fields of the Inputs page are in the Liquid User Guide.

5.1 Fluid#

The Fluid window in the Transient mode, here with properties typed.
Figure 6 The Fluid window in the Transient mode, here with properties typed.

The Bulk modulus is the stiffness of the liquid. With the wall of each pipe it gives the speed of a pressure wave. A fluid of the library comes with its value; with Direct properties it is typed with the others.

The Transient mode works with Constant properties only. A model whose fluid has Variable properties in the steady state is set to Constant properties when the Transient mode is entered: the temperature of the Fluid window is kept, the density and the viscosity are those of that temperature, and a message says so. In the Transient mode the Fluid window does not offer Variable properties, and a project saved so opens with constant properties.

5.2 Pipe#

The Transient page of the Pipe window, with dry pipes enabled.
Figure 7 The Transient page of the Pipe window, with dry pipes enabled.
Table 7 A pipe in the Transient mode
FieldMeaning
Outside diameter, Modulus of elasticity, Poisson's ratioThe wall of the pipe. With the bulk modulus of the fluid and the pipe restraint they give the wave speed
Wave speedCalculated, or typed when the Setting tab is on User Input
Pipe contentWet (full of liquid), or Dry (fills with time). Offered when dry pipes are enabled on the Setting tab
Status: Short pipeOn the Inputs page. The pipe is taken as a loss with no wave in it

A dry pipe starts empty. Water enters it when the element upstream opens; the air ahead of the water leaves through whatever is open at the far end - a nozzle, an air valve, an open end - and is compressed if nothing is. A dry pipe is drawn hollow on the sheet. In the steady state a spray system behind a shut valve is left out of the run as dry; the Transient mode fills it.

5.3 Tank#

The Transient page of the Tank window.
Figure 8 The Transient page of the Tank window.
Table 8 A tank in the Transient mode
FieldMeaning
GeometryVertical: a cylinder standing on its base
Diameter, Tank heightThe size of the tank
Initial Liquid levelThe level at the start of the run
Level in the run: ConstantThe tank is large: its level does not move during the transient
Level in the run: VariesThe level follows the flow in and out. A note is given after the run if the tank overflows or empties
Top inlet nodeThe node, of given pressure, where a line that fills the tank from above ends. None when there is no such line

5.4 Pump#

The Transient page of the Pump window, modelled with its inertia.
Figure 9 The Transient page of the Pump window, modelled with its inertia.
Table 9 A pump in the Transient mode
FieldMeaning
Pump modelling: SimpleThe pump follows its curve at the speed a controller gives it. A trip is a speed that falls on a schedule
Pump modelling: InertiaThe speed after a trip comes from the Total inertia of pump, motor and liquid and the Rated speed. The power curve of the pump must be filled on the Inputs page
Pump modelling: Four quadrantAs Inertia, with the complete characteristic: reverse flow, reverse rotation, the pump as a turbine. Suter data (4Q) opens its table
T-S curve (start-up)The torque of the motor against its speed. Enter data opens its table. A start then follows the motor, not a ramp
The torque of the motor: Speed in per cent of rated speed against Motor torque.
Figure 10 The torque of the motor: Speed in per cent of rated speed against Motor torque.

Auto fill fills the table with the curve of a general-purpose induction motor, scaled to the values typed; Generate draws it. Replace it with the curve of the motor when it is known.

The Suter data of a four quadrant pump, filled with a generic radial pump.
Figure 11 The Suter data of a four quadrant pump, filled with a generic radial pump.

The table holds the dimensionless head WH and torque WB against the angle Theta. It comes filled with a generic radial pump: replace it with the data of the maker. Reset to generic fills it again; Generate draws it. Radial pump (nq 25) fills the table with the published curve of a radial pump of specific speed 25. Rated flow and Rated torque give the rated point; left empty they come from the steady state, the torque at 75 % efficiency.

A pump that stands by at the start of the run: Relative speed 0.
Figure 12 A pump that stands by at the start of the run: Relative speed 0.

A pump is tripped and started by a controller on the pump itself (section 7.3). A pump that stands by at the start of the run is entered with Relative speed 0; Pump on then reads No, and in the Transient mode it follows the speed. A pump that is stopped and has no non-return valve is an open path: flow can pass through it either way.

5.5 Valve#

The Valve window in the Transient mode: the control target is greyed.
Figure 13 The Valve window in the Transient mode: the control target is greyed.

A valve needs its Cv or Kv at full opening and its Valve type, the law between opening and capacity: Linear, Eq Percentage, Quick Opening, or a Valve curve of points. Its Opening (%) is the opening at the start of the run; a controller moves it. A shut valve is entered at 0 %.

5.6 Non-return valve#

The Inertia page of a non-return valve.
Figure 14 The Inertia page of a non-return valve.

Non Return Valve on the Equipment strip places a valve that shuts when the flow would turn back. In the Transient mode its window has an Inertia page.

Table 10 A non-return valve in the Transient mode
FieldMeaning
Modelling: SimpleThe valve shuts at the instant the flow turns back
Modelling: InertiaThe disc moves under the flow, its weight and its spring: it shuts late, with a reverse flow already running, and that is what makes a check valve slam
Valve typeSwing check, Tilting disc, Dual plate or Nozzle
Valve boreDefaulted from the pipe the valve stands in
Disc inertia, Spring constant, Torque coefficient, Damping, Closing preloadThe data of the disc. They are estimated from the bore and the type: replace them with the figures of the datasheet when there are some

5.7 Pressure drop, exchanger, flow meter and nozzle#

6 Surge protection equipment#

The four kinds of protection are on the Equipment strip and are drawn like any other element. Each has one connection to the line, except the surge relief valve, which has an inlet and an outlet. A piece of protection can be ignored from the menu of the right mouse button and made active again, so that a run with it and a run without it are made on one model. Their names start with SRV, ARV, ACM and SRG-T, as set on the Naming tab of Setting.

6.1 Surge relief valve#

The Surge Relief Valve window, type Proportional with reseat.
Figure 15 The Surge Relief Valve window, type Proportional with reseat.
Table 11 The fields of a surge relief valve
FieldMeaning
Set PressureThe pressure at which the valve starts to open
Full Open PressureThe pressure at which it is wide open
Area, Cd FactorThe flow area at full lift and its discharge coefficient
Type: ProportionalThe lift follows the pressure between the two values
Type: Proportional with reseatAs Proportional, but the valve shuts again only when the pressure has fallen by the Blowdown, in per cent
Type: Pop safety valveOpens fully at the set pressure and shuts again after the blowdown
Type: Bursting discThe fields become Burst Pressure and Rupture time. The disc opens once and stays open
Time constantHow fast the valve moves, in seconds
The same window, type Bursting disc.
Figure 16 The same window, type Bursting disc.

The outlet Give the outlet node of a relief valve a pressure, 0 for the atmosphere, or draw the line it discharges into.

6.2 Air valve#

The Air Valve window.
Figure 17 The Air Valve window.

An air valve lets air into the line when the pressure falls under its set pressure and lets it out again when the liquid returns. It has one connection and always opens to the atmosphere. Inlet Valve Flow and Outlet Valve Flow each have their Set Pressure, Diameter and Cd Factor: a large inlet breaks a vacuum; a small outlet holds the air back as a cushion, so that the returning column is slowed instead of striking.

6.3 Accumulator#

The Transient page of the Accumulator window.
Figure 18 The Transient page of the Accumulator window.

An accumulator is a closed vessel with gas over the liquid. It feeds the line when the pressure falls and takes liquid back when it rises. Its Inputs page has its name and its Tank elevation. Its Transient page has the Geometry, the Diameter and Length, the Initial Liquid level, the Initial Pressure and Initial Temperature of the gas and the ratio Gas Cp/Cv, which sets how the gas answers when it is compressed.

6.4 Surge tank#

The Transient page of the Surge Tank window.
Figure 19 The Transient page of the Surge Tank window.

A surge tank is an open tank standing on the line, usually at a high point. Its level moves with the pressure of the line. It needs its Tank elevation on the Inputs page and its Geometry, Diameter, Initial Liquid level and Tank height on the Transient page; a note is given after the run if it overflowed or ran empty.

7 Controllers#

Nothing moves in a run unless a controller moves it. Press Add controller on the Controllers tab, then Select OP under Target Output and choose what the controller acts on: the opening of a valve, the relative speed of a pump, or a pump itself. Remove deletes the controller selected in the list at the left.

Table 12 The Controller mode
ModeWhat the controller does
ManualFollows a schedule of output against time (section 7.1), or a list of trips and starts for a pump (section 7.3)
AutomaticHolds a measured value at its set point (section 7.2)
OffDoes nothing. The controller is kept, to be switched on again, and a scenario can switch it case by case

The Controller square of the Equipment strip places a controller on the sheet; its lines show what it measures and what it moves. A controller in a loop is lettered by what it measures: PC for a pressure, FC for a flow, LC for a level.

7.1 Manual: a schedule#

A controller in Manual mode: the opening of a valve against time.
Figure 20 A controller in Manual mode: the opening of a valve against time.
Table 13 A controller in Manual mode
FieldMeaning
Function type: ConstantThe output keeps the Output value typed for the whole run
Function type: LinearA table of Time (s) against Output. Between two rows the output moves in a straight line. The times must rise from row to row
The plotShows the schedule as typed

An opening is in per cent; a speed is relative to the speed of the pump curve. A closure in 0.1 s is written as two rows 0.1 s apart.

7.2 Automatic: a control loop#

A controller in Automatic mode: the speed of a pump holds a pressure.
Figure 21 A controller in Automatic mode: the speed of a pump holds a pressure.
Table 14 A controller in Automatic mode
FieldMeaning
Select PVWhat is measured: the pressure of a node, the flow of a flow meter or a pressure drop element, the level of a tank
Set PointThe value to hold, in the unit of what is measured
Gain (Kc), Integral time (Ti), Derivative time (Td)The three terms of the controller. The times are in minutes
ActionDirect: the output rises when the measurement rises. Reverse: it falls
OP min (%), OP max (%)The limits of the output
Start from steady stateThe output starts at the value the steady state has, so that the run begins in balance
Hold that opening - no regulationThe output stays at that value for the whole run

With a controller in Automatic, Control links on the Home page draws a dotted line from each controller to the point it measures.

7.3 A pump: trip and start#

Select OP on a pump offers two outputs: its Relative speed, which a schedule or a loop moves, and Trip / Start. With Trip / Start the table of the Manual mode is a list of events: at each time, Trip or Start. Modelled with its inertia (section 5.4), a tripped pump runs down by that inertia and a started pump follows the torque curve of its motor. Several events can follow one another in a run, a trip and a restart for example.

8 Results#

8.1 On the sheet and in the tables#

8.2 Charts#

The charts of section 4.3 are drawn when the run ends. Read under each one the highest and lowest value of every series and its time, and compare them with the limit line. Open in window shows a chart large; its menu of the right mouse button offers View data, Edit chart title, Edit label, Print and Copy as image.

8.3 The report#

PDF Report on the Reports page writes the PDF described in the Liquid User Guide. In the Transient mode, once the Charts tab holds a chart, its window frees the tick Transient charts, which adds one page for every chart. The report of a set of cases is made from the Scenarios tab (section 9.4).

8.4 Forces#

The Forces tab.
Figure 22 The Forces tab.

A pressure wave that passes through a run of pipe pushes on it, because the pressure at its two ends differs for a moment. The Forces tab gives that unbalanced force for the pipe supports and the stress analysis.

Table 15 The Forces tab
FieldMeaning
Add force, Duplicate, RemoveMake a force, copy the one selected, delete it. All forces in the list shows them together
NameThe name of the force
Control volume: Cut 1, Cut 2The run of pipe between two cuts. Each cut is a pipe, a place along it - its start, its end or a distance typed - and its kind
Rigid, ElasticRigid: the piping carries on at the cut - more pipe, an elbow, a tee, a dead end - and nothing is counted there. Elastic: the piping cannot pass a force across - an anchor, an expansion joint, a hose, an open end - and the pressure and momentum at the cut are counted
Axial forceThe force along a straight run. Positive acts from cut 1 towards cut 2
All axesThe force as a vector, for a run that turns. Each cut then needs the direction that points out of the volume
ResultsThe Maximum and the Minimum of the run with their times, and the Steady force before the transient
Force over timeThe force against time; Add to chart puts it on a chart of the Charts tab
Write time history for stress analysisWrites the force against time as an Excel and a CSV file beside the project

The sketch at the top right shows the control volume, its two cuts and the direction of a positive force.

8.5 The message of a run#

A run that has something to say says it once, when it ends. Read it before using a number.

Table 16 What a run can say
SubjectWhat to do
The time step is too large for a pipe: its wave speed is distortedShorten the step on the Integrator tab, or declare the pipe short
A tank or a surge tank that overflowed or ran emptyCheck its size and its initial level
A force that was not calculatedThe message names the force. Check its two cuts
Solved with errors or warningsClick the mark on the status bar for the list, as in the steady state

9 Scenarios#

A scenario of the Transient mode is a list of cases. Each case is the same model with something changed - a controller, a boundary - and all of them are run one after the other and compared. The tab has four pages, chosen at its left, and three buttons at the top right. The line at the top counts the cases, the results watched and those over their limit.

Table 17 The buttons of the Scenarios tab
CommandWhat it does
Run allRuns every case ticked in the Run column
Run selectedRuns the case selected
ReportWrites the report of section 9.4. While the cases run, the same button reads Stop

9.1 Cases#

The Cases page.
Figure 23 The Cases page.
Table 18 The Cases page
CommandWhat it does
The tableCases down the side, what they vary across the top: the mode or the schedule of a controller, the pressure of a node, a value of an element. A cell left empty reads as drawn: that case takes the value of the model
Run, CaseThe tick that puts the case in Run all; its name
Add case, Duplicate, Remove caseAdd a case, copy the one selected, delete it
Add variable, Remove variableAdd a column: what a case can change. Remove the column selected
Edit cell, Clear cellSet the cell selected; empty it so that the case takes the value of the model
A controller cellHolds a mode: Off, a set point, or a schedule shown as what it does - closing or opening, and over how long. Double-click it to set it; type a value into the other cells
Apply to modelLoads the differences of the selected case into the model, which then is that case: the Run of the Transient page runs it and the report reports it as any model

An element can be added to the cases from the sheet: right-click it and choose Add to scenario.

9.2 Outputs#

The Outputs page: what to watch, with its limits.
Figure 24 The Outputs page: what to watch, with its limits.

Add result adds a row: an element, a variable - the same quantities the charts offer - and where along a pipe under At. Max limit and Min limit are judged the right way round: a maximum has to stay below its limit, a minimum above. Chart draws the result for every case on the Charts page. Remove deletes the row selected.

9.3 Charts#

The Charts page: every case on the same axes, with the limits.
Figure 25 The Charts page: every case on the same axes, with the limits.

Each result ticked under Chart is drawn for every case run, with its limits as dashed lines. Every case on the same axes is best for comparing a handful; tick one chart per case to draw each case on its own.

9.4 Summary & Report#

The Summary & Report page after Run all.
Figure 26 The Summary & Report page after Run all.

The Summary gives the watched results, one row per case: the highest and the lowest value, in red where a limit is passed. It fills when the cases are run.

Table 19 What goes in the report
TickWhat it adds
Case list and their differencesThe table of the Cases page
Summary tableThe summary above
ChartsThe charts of the Charts page; One chart per case, four to a page when ticked, otherwise every case on one chart
Exceedances, called outEvery limit passed, named on its own
Force time historiesThe forces against time; Write the force time histories into the same folder writes them as files beside the report

These parts are added to the PDF the program already prints, so the description of the network comes with them. The model itself is not changed by a run of the scenarios.

10 Before a result is used#

Next: the Transient Training Manual works ten cases, from a reservoir, a pipe and a valve to a fire water system that fills, each with its project files.